• Title/Summary/Keyword: Sample preparation method

Search Result 461, Processing Time 0.031 seconds

Magnetic Properties of the Ultrafine Co Particle Systems

  • Perov, N.;Sudarikova, N.;Bagrets, A.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2003
  • The method for evaluation of the particle size distribution of fine particles from hysteresis loop measurements is Presented. The method is illustrated on the SiO$_2$-based Co nanoparticle systems. The influence of technological conditions of sample preparation onto particle size distribution is investigated.

Determination of Enalapril in Human Plasma by High Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry

  • Yoon, Kyung-Hwan;Kim, Won;Park, Jong-Sei;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.878-880
    • /
    • 2004
  • Revered-phase LC-electrospray ionization mass spectrometry was used to selectively determine enalapril from plasma with minimal sample preparation. Detection limit of the method was 1 ng/mL. Precision (within day and between days) and accuracy of the method at various concentrations were acceptable. The analytical technique was used for pharmacokinetic studies after administration of enalapril to human test subjects.

Multivariate Stratification under Consideration of Outliers (이상점을 고려한 다변량 층화)

  • Park, Jin-Woo;Yun, Seok-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.3
    • /
    • pp.377-385
    • /
    • 2008
  • Most of the sample surveys conducted by several statistics preparation agencies are multipurpose surveys inquiring into several distinguishing items through a single sample. In a multipurpose sample design, the stratification tends to be very complex since the stratification variables which are both multivariate and heterogeneous must be considered collectively. In this paper we point out an outlier effect in a multivariate stratification to which the K-means clustering method is applied and propose to consider outliers prior to the stratification step. We also show an empirical stratification effect under consideration of outliers through a case study of sample design for The Rural Living Indicators.

Analysis of the Recovery Rate of Food-borne Pathogens according to Sample Preparation Methods in Animal Origin Foods (축산식품 중 전처리 방법에 따른 식중독균 회수율 분석)

  • Kim, Jong-Hui;Kim, Hyoun Wook;Ham, Jun-Sang;Kim, Bu-Min;Oh, Mi-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.406-413
    • /
    • 2016
  • This study was performed to evaluate and establish a sample preparation method for the detection of food-borne pathogens in animal origin foods. Ham, yogurt, and Korean beef inoculated with Escherichia coli O157:H7, Staphylococcus aureus, and Salmonella Typhimurium, were tested for the effects of diluent composition, processing time, and proportion of diluent to sample. The diluents used were peptone water (PW), Saline solution (SS), Butterfield's phosphate buffered dilution water (BPD), and Buffered peptone water (BPW). The processing time periods considered for the samples were 30, 60, 90, 120, and 300 sec, and the proportions of diluent to samples tested were 1:2, 1:4, 1:9, and 1:19. Yogurt and beef showed the highest number of bacteria when treated with BPW (p < 0.05). However, ham showed no significant difference between the treatments with four different diluents. Optimum proportions of diluent to ham, yogurt, and beef were 1:9, 1:2, and 1:4, respectively. The processing time of 120 sec was chosen as optimum, because it showed the best recovery rate in all sample types. In this manner, detection of food-borne bacteria with the selected optimal conditions was indicated by a recovery rate of more than 85%. These data suggest that an appropriate diluent composition and diluent volume should be used depending on the type of sample, which would thereby increase the accuracy of detecting food-borne bacteria in animal origin foods.

A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods (고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF

Optimization of Microwave-Assisted Method for Accelerated Glycated Hemoglobin Quantification from Amino Acids to Proteins

  • Tran, Thi Thanh Huong;Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.53-58
    • /
    • 2017
  • Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.

Comparative Study and Electrochemical Properties of LiFePO4F Synthesized by Different Routes

  • Huang, Bin;Liu, Suqin;Li, Hongliang;Zhuang, Shuxin;Fang, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2315-2319
    • /
    • 2012
  • To improve the performance of $LiFePO_4F$, a novel sol-gel process is developed. For comparison, ceramic process is also implemented. From X-ray diffraction results we know that each sample adopts a triclinic $P{\bar{1}}$ space group, and they are isostructural with amblygonite and tavorite. The scanning electron microscope images show that the homogeneous grains with the dimension of 300-500 nm is obtained by the sol-gel process; meanwhile the sample particles obtained by ceramic process are as big as 1000-3000 nm. By galvanostatic tests and at electrochemical impedance spectroscopy method, the sample obtained by sol-gel process presents better electrochemical properties than the one obtained by ceramic process.

Sample size using response rate on repeated surveys (계속조사에서 응답률을 반영한 표본크기)

  • Park, Hyeonah;Na, Seongryong
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.5
    • /
    • pp.587-597
    • /
    • 2018
  • Procedures, such as sampling technique, survey method, and questionnaire preparation, are required in order to obtain sample data in accordance with the purpose of a survey. An important procedure is the decision of the sample size formula. The sample size formula is determined by setting the target error and total cost according to the sampling method. In this paper, we propose a sample size formula using population changes over time, estimation error of the previous time and response rate of past data when the target error and the expected response rate are given in the simple random sampling. In actual research, we use estimators that apply complex weights in addition to design-based weights. Therefore, we induce a sample size formula for estimators using design-based weights and nonresponse adjustment coefficients, that can be a formula that reflects differences in response rates when survey methods are changed over time. In addition, we use simulations to compare the proposed formula with the existing sample size formula.

Effect of pH and Reaction Temperature on Mechanical Properties of Hydroxyapatite for Dental prosthesis (치관보철용 Hydroxyapatite의 기계적 물성에 미치는 pH 및 반응온도의 영향)

  • Chung, In-Sung;Her, Ho-Young
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.89-96
    • /
    • 2004
  • Hydroxyapatite powder were synthesized by precipitation method, varying pH, and reaction temperature. The powders were heated at 1,200$^{\circ}{\cdots}$ and 1,300$^{\circ}{\cdots}$ for fabrication of dental prosthesis. The results are as follows: Synthesized powder showed the smallest particle in size, under the conditions of pH 11 and reaction temperature 37$^{\circ}{\cdots}$. The hydroxyapatite was partially converted to $\alpha,\;\beta$-TCP at 1,200$^{\circ}{\cdots}$ and 1,300$^{\circ}{\cdots}$. Mechanical strength of sample was affected by such powder preparation conditions as pH and reaction temperature and sintering temperature. The mechanical strength of sample prepared under the same conditions was increased with increasing pH, reaction temperature and sintering temperature.

  • PDF

Preparation and Magnetic Properties of Co-system Amorphous Thin Film by the Sputter method (스파터법에 의한 Co-계 비정질박막의 제작과 자기특성)

  • 임재근;문현욱;서강수;신용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.190-191
    • /
    • 1994
  • In this paper, We study on the fabrication of amorphous this film of zeromagnetostriction material and the magnetic properties. This films are fabricated by using sputtering method with input power of 400∼607[W], Ar gas pressure of 3∼ 9[mTorr] and target composition of Fe$\sub$4.7/ Co$\sub$74.3/Si$_2$B$\sub$19/. Sample this films with diameter of 14[mm ] and thickness of 27-30[$\mu\textrm{m}$] were obtained through experiments. When we analyzed the magnetic properties before and after annealing with sample thin films, we confirmed that magnetic domain wall amorphous thin films consisted for Neel magnetic domain wall with the width of about 1[$\mu\textrm{m}$].