Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
/
2001.06a
/
pp.1516-1516
/
2001
During the recent years, wine analysis has played an increasing role due the health benefits of phenolic ingredients in red wine [1]. On the other hand there is the need to be able to distinguish between different wine varieties. Consumers want to know if a wine is an adulterated one or if it is based on the pure grape. Producers need to certificate their wines in order to ensure compliance with legal regulations. Up to now, the attempts to investigate the origin of wines were based on high-performance liquid chromatography (HPLC), gas chromatography (GC) and pyrolysis mass spectrometry (PMS) [l,2,3]. These methods need sample pretreatment, long analysis times and therefore lack of high sample throughput. In contradiction to these techniques using near infrared spectroscopy (NIRS), no sample pretreatment is necessary and the analysis time for one sample is only about 10 seconds. Hence, a near infrared spectroscopic method is presented that allows a fast classification of wine varieties in bottled red wines. For this, the spectra of 50 bottles of Cabernet Sauvignon, Lagrein and Sangiovese (Chianti) were recorded without any sample pretreatment over a wavelength range from 1000 to 2500 nm with a resolution of 12 cm$\^$-1/. 10 scans were used for an average spectrum. In order to yield best reproducibility, wines were thermostated at 23$^{\circ}C$ and a optical layer thickness of 3 mm was used. All recorded spectra were partitioned into a calibration and validation set (70% and 30%). Finally, a 3d scatter plot of the different investigated varieties allowed to distinguish between Cabernet Sauvignon, Lagrein and Sangiovese (Chianti). Considering the short analysis times this NRS-method will be an interesting tool for the quality control of wine verification and also for experienced sommeliers.
A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 $\mu$L. 60 min extraction time at 25 ${^{\circ}C}$ was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant ($K_{lh}$) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, $\beta$-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.26
no.1
/
pp.48-57
/
2016
Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.
The analytical results obtained by microwave digestion and acid digestion methods for sample pretreatment to determine metal impurities in silicon wafer by inductively coupled plasma-mass spectrometry (ICP-MS) were compared. In order to decompose the silicon wafer, a mixed solution of $HNO_3$ and HF was added to the sample and the metal elements were determined after removing the silicon matrix by evaporating silicon in the form of Si-F. The recovery percentages of Ni,Cr and Fe were found to be 95∼106% for both microwave digestion and acid digestion methods. The recovery percentage of Cu obtained by the acid digestion method was higher than that obtained by the microwave digestion method. For Zn, however, the microwave digestion method gave better result than the acid digestion method. Fe was added to a silicon wafer using a spin coater. The concentration of Fe in this sample was determined by lCP-MS, and the same results were obtained in the two pretreatment methods.
A quantitative analysis method of halogen elements in volatile organohalogen compounds was established by the Wickbold combustion pretreatment in an enclosed system and ion chromatography. The sample pretreatment parameters of Wickbold combustion were experimentally optimized, and using the determined optimal pretreatment parameters, the reproducibility was estimated by ion chromatography. As a comparison for real samples, NIST certified reference materials (CRMs) were analyzed for the recovery efficiency and reproducibility.
Proceedings of the Korean Vacuum Society Conference
/
2013.08a
/
pp.88-89
/
2013
A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.
Journal of Physiology & Pathology in Korean Medicine
/
v.18
no.6
/
pp.1714-1721
/
2004
This experimental study was designed to investigate the mechanism of Palmul-Tang(PMT) on the changes of cerebral hemodynamics in rats. The changes of cerebral hemodynamics in normal rats were as follows ; The PMT-induced increase in regional cerebral blood flow was significantly inhibited by pretreatment with indomethacin(1㎎/㎏, i.p.), an inhibitor of cyclooxygenase, and was inhibited by methylene blue(10㎍/㎏, i.p.), an inhibitor of guanylate cyclase. The PMT-induced dilation in pial arterial diameter was significantly inhibited by pretreatment with indomethacin and methylene blue. The PMT-induced increase in mean arterial blood pressure was significantly inhibited by pretreatment with indomethacin but was increased by methylene blue. This results were suggested that the mechanism of PMT was mediated by cyclooxygenase. The changes of cytokine production in cerebral ischemic rats were as follows ; In cytokine production of serum by drawing from femoral arterial blood after middle cerebral arterial occlusion 1hr, sample group was decreased IL-1β and TNF-α production compared with control group, IL-10 production of sample group was similar to that of control group, but sample group was significantly increased TGF-β production compared with control group. In cytokine production of serum by drawing from femoral arterial blood after reperfusion 1hr, sample group was significantly decreased IL-1β production compared with control group and decreased TNF-α production compared with control group. IL-10 production of sample group was similar to that of control group, but sample group was significantly increased TGF-β production compared with control group. In cytokine production of serum by drawing from femoral arterial blood after reperfusion 4 hrs, sample group was significantly decreased IL-1β production compared with control group, but IL-10 production of sample group was similar to that of control group. sample group was increased TNF-α and TGF-β production compared with control group. These results suggested that PMT had inhibitive effect on the brain damage by inhibiting IL-1β and TNF-α production, but by accelerating TGF-β production. The present author thought that PMT had an anti-ischemic effect through the improvement of cerebral hemodynamics and inhibitive effect on the brain damage.
An estimate of a change in radioactivity's circumstances around the nuclear power plant is validated with the results of the radioactivity measurements are compared. In this study, to further enhance the reliability of the results obtained from the environmental radioactivity measurements and analysis around the nuclear power plants that have been carried out up to the present. In the korea standard, there is the technical analysis guide for general stable chemical element's, but there is not the technical analysis guide for the radionuclei. therefore the environmental sample collection, the pretreatment of the sample and radionuclide analysis in the sample, the result's of the environmental radioactivity measurements by each organization, etc. are different. It is not sufficient for the database to forecasting a change in radioactivity's circumstances. A comparative study of collection and pretreatment techniques for the soil sample, the results by comparison, the method of minimizing the relative error are proposed. At one side of sample collection, there are going to considered that the surroundings of sample collection like the lay of the land, the provision of the selection standard for the area and pathway of radionuclide adhesion, the coherence of sample collection, etc.. at another side of pretreatment of the sample and measurement in the case of soil sample, how to do homogeneously the soil particle size and the standard tools, i.e. kinds of meshes, must to be selected.
Vitamin B12 deficiency may lead to serious health issues in both infants and adults. A simple analytical method involving sample pretreatment with enzyme, followed by cyanide addition under acidic conditions; separation on an immunoaffinity column; and high-performance liquid chromatography (HPLC) was developed for the rapid detection and quantitation of vitamin B12 in powdered milk. Detection limit and powdered milk recovery were determined by quantitative analysis. The limits of detection and quantitation were 2.71 and 8.21 ㎍/L, respectively. Relative standard deviations of the intra-day and inter-day precisions varied in the ranges of 0.98%-5.31% and 2.16%-3.90%, respectively. Recovery of the analysis varied in the range of 83.41%-106.57%, suggesting that the values were acceptable. Additionally, vitamin B12 content and recovery in SRM 1849a were 54.10 ㎍/kg and 112.24%, respectively. Our results suggested that the analytical method, including the sample pretreatment step, was valid. This analytical method can be implemented in many laboratory-scale experiments that seek to save time and labor. Therefore, this study shows that immunoaffinity-HPLC/ultraviolet is an acceptable technique for constructing a reliable database on vitamin B12 in powdered milk containing starch as well as protein and/or fat in high amounts.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.