• Title/Summary/Keyword: Saline Wastewater

Search Result 27, Processing Time 0.024 seconds

Salt Acclimation Behavior of the Nitrifier Consortium for the Nitrification of Saline Wastewater

  • Seo, Jae-Koan;Kim, Sung-Koo
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.590-593
    • /
    • 2001
  • The effect of salinity on the nitrification efficiency of the nitrifier consortium was evaluated for the nitrification of saline wastewater. The nitrifier consortium, which was the activated sludge acclimated with ammonium as the only energy source, was used as the nitrifier for the salt acclimation. Airlift reactors for the nitrification of ammonia with increasing concentration in saline synthetic wastewater (35 g/I NaCD, and synthetic wastewater without salt as a control, were continuously operated with the nitrifier consortium for 43 days. The ammonia removal rate was about 23g ammonia-N/$m^3$/day in both the absence and presence of the salt. An accumulation of nitrite was observed in the saline nitrification reactor at an early period. However, the nitrite decreased to less than 1 mg/l after 39 days of operation. The salinity increased the acclimation time of the nitrifier consortium to obtain a stable marine nitrification system. However, the salt acclimated system showed the efficient removal of ammonia which was same as that without salt.

  • PDF

Treatment of Saline Wastewater by the Activated Sludge with Nonwoven Fabric Separation

  • Moon, Byung-Hyun;Heo, Jong-Soo;Choi, Hyoung-Sub
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.136-140
    • /
    • 1997
  • Direct membrane separation using nonwoven fabric was applied to saline wastewater treatment by an activated sludge process. A nonwoven fabric module was immersed in an aeration tank. The part of treated was filtered through the module by suction and the rest of that was separated by a settling tank. Various F/M ratios and salt concentrations were applied to investigate stable flux as well as pollutant removal. The pollutant removal efficiencies of nonwoven fabric separation was not affected by F/M ratios and salt concentrations and was higher than that of settling tank separation. The decline in flux was seemed to be caused by the biofilm on nonwoven fabric surface.

  • PDF

Redundancy Analysis Demonstration of the Relevance of Temperature to Ammonia-Oxidizing Bacterial Community Compositions in a Full-Scale Nitrifying Bioreactor Treating Saline Wastewater

  • Park, Hee-Deung;Lee, Seung-Yong;Hwang, Seok-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.4
    • /
    • pp.346-350
    • /
    • 2009
  • Although salt is known to influence the performance of nitrification significantly, it has not been well reported on how salt affects ammonia-oxidizing bacterial(AOB) community compositions and dynamics in wastewater treatment bioreactors. In this study, these questions were evaluated in a full-scale bioreactor treating saline wastewater. Clone library analysis for the ammonia monooxygenase subunit A gene revealed that AOB belonging to the Nitrosomonas europaea and the N. oligotropha lineages inhabited in the bioreactor. Terminal restriction fragment length polymorphism analysis for monthly samples demonstrated a fluctuation pattern among AOB populations, although AOB within the N. europaea lineage were dominant during the test period. Correlation analysis between patterns of terminal restriction fragments and environmental variables suggested that sodium, chloride, and sulfate were less important; rather, temperature was the most significant factor affecting the AOB community in the bioreactor.

Performance of a submerged membrane bioreactor for wastewater mimicking fish meal processing effluent

  • Lopez, Guadalupe;Almendariz, Francisco J.;Heran, Marc;Lesage, Geoffroy;Perez, Sergio
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.263-271
    • /
    • 2018
  • The objective of this work was to analyze organic matter removal, nitrification, biomass growth and membrane fouling in a submerged flat-sheet membrane bioreactor, fed with synthetic wastewater, of similar composition to the effluents generated in a fish meal industry. After biomass acclimatization with saline conditions of 12 gNaCl/L and COD/N ratio of 15 in the bioreactor, results showed that the organic matter removal was higher than 90%, for all organic loading rates (0.8, 1, 1.33 and $2gCOD/L{\cdot}d$) and nitrogen loading rates (0.053, 0.067, 0.089 and $0.133gN/L{\cdot}d$) tested during the study. However, nitrification was only carried out with the lowest OLR ($0.8gCOD/L{\cdot}d$) and NLR ($0.053gN/L{\cdot}d$). An excessive concentration of organic matter in the wastewater appears as a limiting factor to this process' operating conditions, where nitrification values of 65% were reached, including nitrogen assimilation to produce biomass. The analysis of membrane fouling showed that the bio-cake formation at the membrane surface is the most impacting mechanism responsible of this phenomenon and it was demonstrated that organic and nitrogen loading rates variations affected membrane fouling rate.

Removal of Organic and Nutrients in Fish Market Wastewater using Sequencing Batch Reactor (SBR) (SBR공정을 이용한 수산물 위판장 폐수에서 유기물 및 질소 제거)

  • Kim, Sung-Ju;Lee, Dae-Hee;Park, Hung-Suck
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • This research work aims at treating saline wastewater generated from a fish market using four Sequencing Batch Reactors (SBR) operated under different conditions. The effect of C/N ratio (3, 6) and salt concentration (0.5~2%) on organic and nitrogen removal was studied. The synthetic wastewater prepared with glucose ($C_6H_{12}O_6$) as the primary carbon source along with ammonium chloride ($NH_4Cl$) was used in the three reactors. The fill, anoxic, aeration, settle and draw conditions were 2 hr, 4 hr, 4 hr and 2 hr respectively. The fourth reactor was operated at different conditions to investigate the practical feasibility of SBR application to handle fish market wastewater generated in Ulsan city that had fluctuating loading characteristics. Though the unacclimated sludge was initially affected by the salt concentration, the acclimated sludge removed 95% of the organics irrespective of the NaCl concentration and C/N ratio. However, the removal of nitrogen was affected more by C/N ratio than the salt concentration. While handling fish market wastewater, though the organic and nitrogen loading rate were varying between $0.009{\sim}0.259gCOD_{OH}/gVSS/day$ and 0.005~0.034 gN/gVSS/day, the effluent concentrations were far less than the effluent standard of $120mgCOD_{OH}/L$ and 60 mgN/L respectively, except when loading rates were fluctuating and 4 times higher than the average.

Anaerobic/Aerobic Biological Reaction Characteristics of the Marine Products Industry Wastewater (수산물가공폐수의 혐기.호기 생물학적 반응특성)

  • Choi, Yong-Bum;Kim, Gau-You;Kwon, Jae-Hyouk
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.6
    • /
    • pp.452-458
    • /
    • 2008
  • This study was undertaken to establish the biological reaction characteristics of the marine products industry wastewater which contains high concentrations of organic matter and saline. As the S/I is varied from 0.3 to 1.2, the results were follows : the observed ultimate anaerobic biodegradability varied from 72.0 to 88.0%, the first order reaction rate varied from 0.1735 to $0.3420\;day^{-1}$ and the second order reaction rate varied from 0.0132 to $0.0295\;day^{-1}$. When S/I was 0.9, the first order reaction rate had a maximum value, but the variations of the second order reaction rate were less than 1st-order reaction rate. When the operation time exceeded 2 days the gas production rapidly increased. The source of this rapid increase was due to that the activity of the granular sludge used in this study being faster than that of conventional sludge. Under aerobic condition, the characteristics of organic matter were as follows: the marine industry wastewater used in this study contained about 81% of biodegradable matter, and it was divided into readily biodegradable COD(Ss), slowly biodegradable COD(Xs), soluble COD(Si) and inert suspended COD (Xi). The percentages of each COD were 87.3%, 23.9%, 6.4% and 12.4% respectively.

Effects of Aerobic and Non-Aerobic Starvation on SBR Performance When Treating Saline Wastewater

  • Moon, Byung-Hyun;Park, Kyung-Hun;Kim, Sang-Soo;Yoon, Cho-Hee
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.139-144
    • /
    • 2012
  • In this study, the effects of starvation on floc characteristics when treating saline wastewater using a sequencing batch reactor (SBR) were investigated. The effectiveness over 5 days of starvation for aerobic and non-aerobic strategies for maintaining the physical characteristics of floc-forming sludge and the recovery period needed to regain the initial pollutant removal efficiency were investigated. Experiment results revealed that the sludge volume index (SVI) increased and the floc size and fractal dimension decreased after starvation under both aerobic and non-aerobic conditions. Sludge settleability deteriorated faster under aerobic conditions compared to non-aerobic conditions. Under non-aerobic conditions, the SBR required less time to return to its initial pollutant removal efficiency and settleability. Floc size, fractal dimension, and SVI were observed to be fairly correlated with each other. The results demonstrated that it was better to maintain the sludge under non-aerobic rather than aerobic starvation, because it adapted to, resisted starvation and had a quicker re-start afterward.

Treatment of high-salinity wastewater after the resin regeneration using VMD

  • Gao, Junyu;Wang, Manxiang;Yun, Yanbin
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, vacuum membrane distillation (VMD) was used to treat high-salinity wastewater (concentration about 17%) discharged by chlor-alkali plant after resin regeneration. The feasibility of VMD for the treatment of real saline wastewater by using Polyvinylidene fluoride (PVDF) microporous plate membrane with a pore diameter of $0.2{\mu}m$ was investigated. The effects of critical operating parameters such as feed temperature, velocity, vacuum degree and concentration on the permeate water flux were analyzed. Numerical simulation was used to predict the flux and the obtained results were in good agreement with the experimental data. The results showed that an increase in the operating conditions could greatly promote the permeate water flux which in turn decreased with an increase in the concentration. When the concentration varied from 17 to 25%, the permeate water flux dropped marginally with time indicating that the concentration was not sensitive to the decrease in permeate water flux. The permeate water flux decreased sharply until zero due to the membrane fouling resistance as the concentration varied from 25 to 26%. However, the conductivity of the produced water was well maintained and the average value was measured to be $4.98{\mu}s/cm$. Furthermore, a salt rejection of more than 99.99% was achieved. Overall, the outcome of this investigation clearly indicates that VMD has the potential for treating high-salinity wastewater.

The Practical Study for the Treatment of Fish Processing Saline Wastewater Using Immersed MBR (iMBR 공정을 이용한 수산물가공폐수 처리에 관한 실증적 고찰)

  • Park, Seung Kyun;Lee, Dong Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.469-475
    • /
    • 2016
  • The study is the result of an practical operation analysis for the full scale fishery product wastewater treatment plant with immersed MBR (iMBR) process. Since fishery product industries show a wide range of wastewater generation by the season, design and operation of the equalization basin are very important factor. The aeration system for the equalization basin mixing can save the chemical consumption for followed system through the restriction of acid fermentation. The concentrations of wastewater primary DAF process treated were BOD 2,291 mg/L, $COD_{Mn}$ 530 mg/L, SS 256.8 mg/L, T-N 38 mg/L, T-P 13.5 mg/L respectively. It was considered that iMBR is the most efficient biological process for high salinity content wastewater since It is irrelevant to the capability of the sludge precipitation. SADp and SADm were 0.31, $26.5m^3/hr{\cdot}m^3$ respectively. In iMBR process, the critical F/M ratio was derived at 0.08~0.10 gBOD/gMLSS by analysing the correlations between MLSS, normalized TMP and temperature. The effluent concentrations were BOD 1.8 mg/L, $COD_{Mn}$ 12.4 mg/L, SS 1.0 mg/L, T-N 7.85 mg/L, T-P 0.1 mg/L and removal efficiencies were 99.9%, 97.6%, 96.3%, 95.7%, 97.8% respectively.

Environmental Restoration and Water Quality Management Modeling of Coastal Area by Reuse of Treated Wastewater (하수처리수 재이용에 따른 하천과 해역의 환경복원 및 수질관리 모델링)

  • Lee, Dae-In;Yoon, Yang-Ho;Park, Il-Heum;Lee, Gyu-Hyong;Cho, Hyeon-Seo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.505-521
    • /
    • 2007
  • This study estimated response of water duality and pollutant behavior according to the discharge and reuse of treated wastewater by three-dimensional eco-hydrodynamic model, and suggest plan that water quality management and environmental restoration in the coastal area including urban stream of Yeosu, Korea. Dispersions of low-saline water and COD by treated wastewater loads (design facility capacity, about $110,000m^3/d$) were very limited in near of effluent site. Nutrients, however, increase compared to the other water quality factors, especially total nitrogen was very sensitive to input loads. When reuse some of treated wastewater to Yeondeung stream, nitrogen was big influence on estuarine water quality. Although current characteristics of treated wastewater such as discharge and water quality were negligible to the change of marine environment, effluent concentration of COD, TN and TP, especially 40% of TN, are reduced within the allowable pollutant loads for satisfy environmental capacity and recommended water duality criteria. Also, controls of input point/non-point sources to Yeondeung stream and base concentration of pollutants in coastal sea itself are very necessary.