• 제목/요약/키워드: Safety-critical System

검색결과 876건 처리시간 0.025초

첨단 경량전철 열차제어시스템 안전엔지니어링 기술동향 (Basic Requirements for the Application of Risk Concept on Railway Safety Improvements)

  • 조연옥;왕종배;김상암
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1467-1473
    • /
    • 2004
  • It requires different safety programs from those of the typical train control systems to develop AGT systems applying train control system based on communication technology. Especially Advanced LRT system involves the processes that have the various safety functions being conducted by softwares and also have characteristics that should have special interest in validation of interface specification. The core items for the safety engineering for LRT control systems are hardware & software engineering, safety-critical system safety engineering, application software validation & verification technologies. In this paper the trends of the technologies for the mentioned core-items are described.

  • PDF

HVAC 파라미터 모니터링 시스템에 대한 고찰 (Computer Validation 중심으로) (A Study on HVAC Parameter Monitoring System (Regarding Computer Validation))

  • 김종구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • This article presents practical advice regarding the implementation and management of an impeccable Building Management System. The BMS was introduced to the series of computerized systems including manufacturing, storage, distribution, and quality control. Recently revised GMP regulation is requesting an improvement in drug product quality regulatory system by computer system validation. Quality is critical to guarantee the efficacy and the safety of drugs and is approved in the evaluation process after the audit trail application. HVAC parameter monitoring system will record the identity of operators entering or confirming critical data. Authority to amend entered data should be restricted to nominated persons. Any alteration to an entry of critical data should be authorized in advance and recorded with the reason for the change.

  • PDF

SB2등급 연성베리어의 충돌지점(CIP)에 대한 연구 (Study on Critical Impact Point for a SB2 Class Flexible Barrier)

  • 허연희;김용국;고만기;김기동
    • 한국도로학회논문집
    • /
    • 제15권4호
    • /
    • pp.127-133
    • /
    • 2013
  • PURPOSES : The impact performance of flexible barrier system such as structural response, vehicular motion and occupant safety vary depending on the impact point. Thus, to properly evaluate the performance of a flexible barrier system, impact should be made to a point which will lead to the worst possible results. This point is called the Critical Impact Point (CIP). This paper presents the way to determine the CIP for a SB2 class flexible barrier system which is consisted of Thrie-Beam rail and circular hollow tube post of 2m span. METHODS: Barrier VII simulations were made for impact points; Case 1 at a post, Case 2 at 1/3 span downstream from a post, Case 3 at middle of the span, Case 4 at 2/3 span downstream from a post. For the structural performance (deflections), impact simulation of 8000kg-65km/h-15degree was used, and for vehicle motion and occupant safety, simulation of 1300kg-80km/h-20degree impact was made and analysed. RESULTS: Case 1 gave the largest dynamic deflection of 75.72cm and also gave the largest snag value of 44.3cm. Occupant safety and exit angle of the vehicle after the impact were not sensitive to the impact point and were all below the allowable limit. CONCLUSIONS : For the SB2 class flexible barrier system's CIP can be regarded as a post which is sufficiently away from the end of Length of Need in order to avoid the end-effect of the barrier system. It can be more economic in the long run because the normal concrete pavement material is likely to cost more due to higher probability of maintenance and repair and higher social cost due to traffic accident, etc.

Design and Development of a Functional Safety Compliant Electric Power Steering System

  • Lee, Kyung-Jung;Lee, Ki-Ho;Moon, Chanwoo;Chang, Hyuk-Jun;Ahn, Hyun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1915-1920
    • /
    • 2015
  • ISO 26262 is an international standard for the functional safety of electric and electronic systems in vehicles, and this standard has become a major issue in the automotive industry. In this paper, a functional safety compliant electronic control unit (ECU) for an electric power steering (EPS) system and a demonstration purposed EPS system are developed, and a software and hardware structure for a safety critical system is presented. EPS is the most recently introduced power steering technology for vehicles, and it can improve driver’s convenience and fuel efficiency. In conformity with the design process specified in ISO 26262, the Automotive Safety Integrity Level (ASIL) of an EPS system is evaluated, and hardware and software are designed based on an asymmetric dual processing unit architecture and an external watchdog. The developed EPS system effectively demonstrates the fault detection and diagnostic functions of a functional safety compliant ECU as well as the basic EPS functions.

중환자실 간호사의 2교대와 3교대근무 간 근무 만족도, 수면, 피로, 삶의 질과 환자안전사고 비교 (Comparison of Shift Satisfaction, Sleep, Fatigue, Quality of Life, and Patient Safety Incidents Between Two-Shift and Three-Shift Intensive Care Unit Nurses)

  • 채민진;최수정
    • 중환자간호학회지
    • /
    • 제13권2호
    • /
    • pp.1-11
    • /
    • 2020
  • Purpose : The aim of this study was to compare shift satisfaction, sleep, fatigue, quality of life (QOL), and patient safety incidents between a newly implemented two-shift system and a traditional three-shift system. Methods : A total of 127 intensive care unit nurses (48 two-shift nurses and 79 three-shift nurses) working in a tertiary hospital in Seoul were recruited from January 1, 2017, to March 31, 2017. They completed a self-reported questionnaire about their work hours, shift satisfaction, sleep patterns, sleep quality, fatigue, QOL, and patient safety incidents in the past 2 weeks. Data were analyzed using SPSS version 23.0. Results : The two-shift group showed higher shift satisfaction scores compared with the three-shift group (6.93 vs. 4.37, p<.001). Sleep latency was shorter and sleep quality was better in the two-shift group compared with the three-shift group. There were no significant differences in other sleep parameters, fatigue, QOL, and patient safety incidents between the two groups. Conclusion : Although a two-shift system did not improve nurses' fatigue or QOL in this study, it may effectively serve as an alternative shift-work system that can increase sleep quality and shift satisfaction without increasing patient safety incidents.

적분모델을 이용한 난연처리된 Douglas fir의 화재특성 예측 (Predicting of Fire Characteristics of Flame Retardant Treated Douglas fir Using an Integral Model)

  • 박형주;김홍;하동명
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.98-104
    • /
    • 2005
  • This study experimentally and theoretically examines the fire characteristics of 100- by 100- by 50-mm samples of flame retardant treated Douglas fir. Samples were exposed to a range of incident heat fluxes 10 to $50kW/m^2$. The time to ignition measurements obtained from the cone heater were used to derive characteristic properties of the materials. A one-dimensional integral model has been used to predict the, time to ignition, critical heat flux and ignition temperature of samples. Ignition data and best-fit curves confirm ${{\dot{q}}_i}^{'}{\rightarrow}{{\dot{q}}_{cr}^{'}\;then\;t_{ig}{\rightarrow}{\infty}$ and when ${{\dot{q}}_i}^'{\gg}{{\dot{q}}_{cr}^'\;then\;t_{ig}{\rightarrow}0$. And Ignition of flame retardant treated samples occurred not at incident heat flux of bellow $10kW/m^2.$. By a one-dimensional integral model, the critical heat flux of each samples was predicted $10.21kW/m^2,\;11.82kW/m^2,\;and\;14.16kW/m^2$ for the D-N, D-F2, and D-F4, respectively. In ignition temperature of each samples, flame retardant treated samples were measured high about $50^{\circ}C$ than non-treated samples. Water-soluble flame retardant used in this study finds out more effect in delay of time to ignition when incident heat flux is low than high.

기업에서 재난관리시스템 활용에 관한 연구 (A Study on the Application of Disaster Management System for Business Area)

  • 오세중;김찬오
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.132-136
    • /
    • 2013
  • Even though most of domestic corporations are doing various activities to reduce disasters, it is true that those are actually limited to some parts of business or the formalities in order to obtain specific certificates. For that reason, this writer study a efficient utilization of a guideline about accident provision and business continuity management for less disasters of companies, prevent interruption of critical mission. In short, it is required to operate an effective disaster recovery system and safety management system integrated by a mutual recognition on the relevant parts and different parts. And there is a need to establish a integrated recovery center in order to manage disaster recovery system realistic and effective.

회전익기 연료펌프 안전성 평가 분석 (Safety Assessment Analysis of the Rotorcraft Fuel Pumps)

  • 이정훈;박장원
    • 한국항공운항학회지
    • /
    • 제21권2호
    • /
    • pp.21-25
    • /
    • 2013
  • The system and components for aircraft are required the design data on which the safety requirements are properly reflected for their certification. This paper presents the procedure and results of a safety assessments analysis for the rotorcraft fuel pumps in oder to confirm and verify them. The fuel pumps design assessment must be performed, including a detailed failure analysis to identify all failures that will prevent continued safe flight or safe landing. In order to assess the fuel pumps design safety, not only system safety hazard analysis and but FTA(Fault Tree Analysis) for proofing the safety objective of the fuel pumps are performed. The results of the safety assessment for fuel pumps validate that no single failure or malfunction could result in catastrophic failure or critical accidents of the rotorcraft.

Measurement of missing video frames in NPP control room monitoring system using Kalman filter

  • Mrityunjay Chaubey;Lalit Kumar Singh;Manjari Gupta
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.37-44
    • /
    • 2023
  • Using the Kalman filtering technique, we propose a novel method for estimating the missing video frames to monitor the activities inside the control room of a nuclear power plant (NPP). The purpose of this study is to reinforce the existing security and safety procedures in the control room of an NPP. The NPP control room serves as the nervous system of the plant, with instrumentation and control systems used to monitor and control critical plant parameters. Because the safety and security of the NPP control room are critical, it must be monitored closely by security cameras in order to assess and reduce the onset of any incidents and accidents that could adversely impact the safety of the NPP. However, for a variety of technical and administrative reasons, continuous monitoring may be interrupted. Because of the interruption, one or more frames of the video may be distorted or missing, making it difficult to identify the activity during this time period. This could endanger overall safety. The demonstrated Kalman filter model estimates the value of the missing frame pixel-by-pixel using information from the frame that occurred in the video sequence before it and the frame that will occur in the video sequence after it. The results of the experiment provide evidence of the effectiveness of the algorithm.

경전철 역사 개념설계 단계에서 기능분석 결과를 활용한 안전요구사항의 생성방법에 관한 연구 (On the Development of Safety Requirements Based on Functional Analysis of LRT Stations in Concept Development Stage)

  • 김주욱;정호전;박기준;김주락;한석윤;이재천
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.382-391
    • /
    • 2016
  • 철도와 같은 안전중시 시스템에 대해 체계적인 안전관리의 필요성이 점차 커지고 있어 IEC 61508, 62278, ISO 26262 등의 안전과 관련된 표준들이 제정되었고, 관련연구가 수행되고 있다. 그중 안전 프로세스의 중요한 활동인 위험원 분석에 대하여 다양한 연구가 수행되어 왔으나, 시스템설계 프로세스와의 구체적인 연계성이 부족하였다. 또한 기존의 위험원 분석방법은 시스템 설계가 상당 수준 진행된 하드웨어 및 소프트웨어 구성품 정보에 의존하기 때문에, 설계 변경에 많은 비용과 일정이 소요된다. 이러한 문제들을 해결하기 위해서 본 논문에서는 시스템 설계초기인 개념설계 단계에서 수행한 기능분석 결과를 안전 프로세스에서 직접적으로 활용하여 위험원을 분석하고 이를 바탕으로 위험을 줄이기 위해 필요한 안전요구사항을 생성하는 방법에 대하여 연구를 수행하였다. 설계 초기에 위험원 분석 및 안전요구사항의 도출을 수행함으로써, 향후 요구사항 변경 등 여러 요인으로 시스템 설계 및 안전 설계의 변경 시에 이를 반영하는데 있어서 시간 및 비용 관점에서 상대적으로 효율적인 접근 방법이 된다. 한편, 사례연구로서 본 논문에서 제시한 방법을 경전철 역사의 안전성을 확보하기 위한 요구사항의 도출에 적용하는 연구를 수행하였다.