• Title/Summary/Keyword: Safety standards performance

Search Result 468, Processing Time 0.028 seconds

A Study on the Performance Standards for a Natural Type Landscaping Rocks by Utilizing GFRC(Glass Fiber Reinforced Concrete) (유리섬유강화콘크리트를 이용한 자연형 경관석의 성능기준 연구)

  • Yoon, Bok-Mo;Koo, Bon-Hak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.33-42
    • /
    • 2012
  • This study aims to establish the performance standard for natural type landscape stone GFRC. The required performance such as material performance, structural safety performance, durability performance, and landscape performance were selected through an examination of domestic and overseas performance related references and examples, and through the questionnaires obtained from 40 experts, and the verified items and performance standards were proposed. Among the required performances, the material performance(glass fiber content, air-dried gravity), structural safety performance(flexural strength, compressive strength), durability performance(crack, corrosion resistance), and landscape performance(texture, efflorescence) were selected through the questionnaires obtained from the experts. In the case of material performance and structural safety performance with the corresponding standards that existed, final performance evaluation standard was proposed by conducting a test and comparing it with the existing standard sample, and in the case of durability performance and landscape performance on which standard does not existed, they were verified by measuring directly through field examination of formative landscape items such as artificial waterfall etc. In this study, performance standard for the material on natural type landscaping rocks GFRC and items which can be evaluated after construction such as material performance, structural safety performance, durability performance, landscape performance, and so forth were proposed, however, follow up study for pro-environmental and ecological performance standard which were recently gaining force would be required through a continuous monitoring for the construction samples afterwards.

TSO Authorization of Airborne Multipurpose Electronic Displays (항공기용 다목적 디스플레이의 기술표준품 인증)

  • Cheon, Young-Ho;Lee, Seoung-Pil;Park, Jun-Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.765-776
    • /
    • 2013
  • Civilian aircraft industry, even if the superior performance of the product in order to ensure the safety of aircraft navigation safety requirements necessary for compliance does not receive a legally recognized can not be used in aircraft characteristics. These are applied in a variety of safety in avionics for navigation of civil aircraft certification standards for the technology is implemented. KTSO-C113 aircraft for the purpose of electronic display technology to authenticate standard contains minimum performance standards. Standard design and manufacturing technology for type approval means approval by mounting the aircraft in order to use a separate approval is required. Through this paper, multi-display technology standards for aircraft type certification approval system and demonstrate compliance with the requirements for the certification practices introduced are presented.

A Study on the Standard of Test Method for Estimation of Usage Environment Safety and Performance of U-health Medical Device (유헬스케어의료기기의 사용환경 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Cha, J.H.;Hur, C.H.;Park, K.J.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • According to graying of population and income enlargement of people, interest about U-Healthcare of new form fusing with IT technology are enlarged. Need a estimation technology and standard of test method for safety and performance considering usage environment of U-Healthcare medical device. In this research, developed the standard of test method for usage environment safety and performance of U-Healthcare medical device referring IEC standards and KS standards.

An Empirical Study on the Effect of International Standards Management System Integration on Business Performance - Focused on Quality, Environment and Health & safety management system- (국제표준 경영시스템 통합이 경영성과에 미치는 영향에 대한 실증적 연구 - 품질, 환경 및 안전·보건 경영시스템 중심으로 -)

  • Kim, Yeun Sung;Suk, Ho Sam;Sung, Do Kyong
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.781-810
    • /
    • 2017
  • Purpose: This paper studied about the integration for management system of representative international standard related to sustainable development. The well-known International standards such as ISO 9001, ISO 14001 and OHSAS 18001 (ISO 45001) can be operated in accordance with the organizational situation individually, or in a variety of ways of integration. It can be applied to help organizations utilizing the newly established "ISO IEC Directive Part1 Annex SL", when integrating quality, environmental and safety & health management systems based on international standards. Methods: We conducted an empirical survey of management executives and experts to study how three factors (management systems, organizational capabilities and integration methods) could affect business performance. Results: The questionnaire was analyzed using AMOS structural equation model. Quality, environmental and safety and health management systems affected management performance, and integration methods of management system affected business efficiency, risk performance and financial performance. Integration method is also important because organizational competence affects various aspects of integrated management. However, factors that affect integration should also be considered in terms of organizational capabilities. This is because organizational capacity influences the integration plan. Conclusion: To integrate the document system at the strategic level, management should actively participate in integrated operations to integrate organizations, eliminate duplicate tasks, and foster document integration experts to reflect the characteristics of individual standard. In the case of document integration, quality management is focusing, but once ISO 45001 is issued, the use of Annex SL is increasing, and Quality, environment and safety & health integration will also be expanded. It is possible to increase the effect of integration by strategically approaching and establishing organization document system rather than simple integration according to management system standard arrangement.

Improving Current Status of Safety Management for Domestic Performance Theatre (국내 공연장 안전관리 실태 및 개선 대책에 관한 연구)

  • Gal, Won-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.35-41
    • /
    • 2008
  • It is a fact that domestic performance art has been sharply progressed but it is focused on only performance quality technique, not on safety of performers and the audience. It is a pity that people's effort to keep safe stage environment have not traced to innovative change, eventually leading to be forced to perform under hazardous condition. This study is to find out and identify that domestic regulation and accident cases are investigated and compared with cases of advanced countries, to verify that performer and the audience are main elements to develop performance art. And it is to show more effective safety measure after pointing out hazardous elements. Research change is limited to review only performance ones of all cultural facilities and to review accident cases from these places to show reasonable safety measures for stage facilities. Operation manager covers almost all of areas such as devices, management, despite a fact that they take charge of stage facilities, illumination, sounds, already. Some conclusions are as follows; 1) performance theatre-related regulations should be established again. domestic safety standards for performance theatre safety should be established. 2) characteristic and purpose of performance place should be clarified at the stage planning and design of them 3) operation expert performance place is required to be trained to cover emergency situation at any time.

A Research Study on Seoul Region School Nutritionists' Perception of HACCP System, CCP Control Standards & Performance Conditions and Sanitation & Safety Inspection - Focusing on CCP 1 & CCP 2 - (서울지역 학교 영양(교)사의 HACCP 시스템 CCP 관리기준 수행실태 및 위생·안전점검에 대한 인식 조사 연구 - CCP 1과 CCP 2를 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Ae-Rang
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.3
    • /
    • pp.447-457
    • /
    • 2014
  • A research was conducted on Seoul regional elementary, middle, and high school nutritionists to study about their perception of HACCP control standards & performance conditions and sanitation & safety inspection, to seek for more efficient methods of school meals' sanitation system settlement. All surveys were distributed and collected via email. A total of 305 survey papers were collected, and out of these, 300 school results were analyzed. As for CCP 1 performance conditions, 43.3% of the nutritionist put emphasis on temperature control for cooking duration and 71.0% said that they manage both temperature and PHF food control. In CCP 2 stage, 65.8% of the nutritionists maintained the food's temperature, and 56.7% documented the recordings after cooking. A total of 79.3% of the schools scored above 90 points on school meal sanitation & safety inspection, 3.72 points on necessity for revisions, 3.38 points on objectivity, and 3.34 points on reliability. As for these results, a clear CCP control criteria as well as training must be set. Also, because the necessity of revision for sanitation & safety inspection is higher than reliability and objectivity, appropriate complementary measures must be taken.

General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008- (진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008-)

  • Kang, Hee-Doo;Dong, Kyung-Rae;Kweon, Dae-Cheol;Choi, Jun-Gu;Jeong, Jae-Ho;Jung, Jae-Eun;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

Evaluation criteria for filling performance of high-flowing concrete using steel-concrete panel

  • Dong Kyu Lee;Jae Seon Kim;Myoung Sung Choi
    • Advances in concrete construction
    • /
    • v.16 no.5
    • /
    • pp.231-241
    • /
    • 2023
  • The purpose of this study was to evaluate the practical application of high-flowing concrete for a steel-concrete panel (SCP) module for a liquefied natural gas (LNG) storage tank. We evaluated the physical properties and filling performance of the developed concrete for the SCP module. First, slump tests were performed to evaluate the performance of the proposed standards for the filling tests. All the concrete mixes showed satisfactory performance. Based on the results of the previous study, the reliability of the required time measured using the T500 test and the rheometer results measured before and after pumping was 0.94, indicating that segregation and blocking should not occur. L-box and U-box tests were conducted before and after pumping. All the recommended standards showed satisfactory performance. The SCP structural module for LNG storage tanks was fabricated to a full scale to evaluate its practical application at the final site. Satisfactory filling performance was confirmed for all the specimens.

The Development of a SVR-based Empirical Model for the Effect of the Unbalanced Floor Height on MVC of Lifting Task (불균형한 바닥높이가 들기 작업의 최대발휘근력에 미치는 영향 분석을 위한 SVR 예측모델 설계)

  • Oh, Hyunsoo;Chang, Seong Rok;Kim, Younghwan;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.153-159
    • /
    • 2014
  • Low back pain is one of major issues in musculoskeletal diseases mainly caused by MMH (Manual Material Handling) tasks. In Korea, the standards of NIOSH(National Institute for Occupational Safety and Health) Lift Equations in U. S. A. have been most widely used. However, there is no standard in case the height of one feet is higher than that of another one. Moreover, since the standards are developed in U. S. A., there are many limitations for the applicability of Korean workers. In this study, MVC(Maximum Voluntary Contraction) for four postures are measured and an empirical model based on SVR(Support Vector Regression) is constructed. Constructing SVR model, PSO(Particle Swarm Optimization) is employed to investigate the optimal parameters of SVR. The results show that the performance of this empirical model is approximately accurate, even if the deviation of experimental values is large due to the individual differences. This empirical model may contribute to establish the standards of MMH tasks in Korea.

Structural Performance Evaluation of System Scaffolding for Elevator Installation Work (엘리베이터 설치 작업용 시스템 비계의 구조 성능 평가)

  • Jong Moon Hwang;Gi Yeol Lee
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.61-68
    • /
    • 2023
  • This study performed a structural performance evaluation of a system scaffolding for elevator installation work developed in previous studies. The structural performance was evaluated via a structural test conducted to apply the working load specified in the design standard. The deflection of the horizontal member and the stress of each member constituting the system scaffolding were measured. Consequently, the structural safety evaluation including structural behavior and required performance was performed using the deflection and stresses measured from the structural test. The structural test and safety evaluation results based on the heavy working load corresponding to the design load indicated that the deflection, which is the performance criterion of the horizontal member, did not exceed the allowable value. Further, each member's stress, which is a safety evaluation indicator, did not exceed the allowable strength for both horizontal and vertical members with bending behavior and fordable bracing with tensile behavior, while also satisfying the required safety factor. In addition, the results confirmed the safety against deformation, partial damage, and destruction owing to excessive and maximum load. Therefore, the system scaffolding developed in this study satisfies both the structural performance and safety required by the design standards; thus, it can be applied to elevator installation work sites.