• Title/Summary/Keyword: Safety protective equipment

Search Result 226, Processing Time 0.025 seconds

Factors Affecting Radiation Protection Behaviors among Emergency Room Nurses (응급실 간호사의 방사선 방어행위 영향요인)

  • Lee, Su Jin;Boo, Sunjoo;Ahn, Jeong-Ah;You, Mi-Ae
    • Journal of Korean Critical Care Nursing
    • /
    • v.13 no.1
    • /
    • pp.15-26
    • /
    • 2020
  • Purpose : This study aimed to examine factors affecting radiation protective behaviors among emergency room nurses by assessing knowledge, attitude, and environment for radiation protection. Methods : The study employed a cross-sectional design. Subjects were a convenience sample of 129 nurses working in emergency rooms of three general hospitals. Data were collected using self-report questionnaires and analyzed using t-test, ANOVA, Pearson correlation coefficients, and multiple regression. Results : The more the nurses received radiation safety education (t=2.26, p=.026), used protective gear (t=4.40, p<.001), and took health screenings (t=2.65, p=.009), the higher their levels of radiation protection behavior. There were significant relations between radiation protective behaviors and attitude (r=.27, p=.002), and radiation protective behaviors and environment for radiation protection (r=.55, p<.001). The factors affecting radiation protective behaviors were protective environment (β=.53, p<.001), protective attitude (β=.32, p<.001), and the use of protective gear (β=.24, p=.002). Conclusions : The government, hospital administrators, and radiation protection-related organization should adopt the following measures to protect emergency room nurses from radiation: research and development of shield instrument, medical examination for emergency room nurses, protocol development of radiation protection behaviors, extension of education chances of radiation protection, and encouraging the use of protective equipment.

Radiation safety: a focus on lead aprons and thyroid shields in interventional pain management

  • Cheon, Bo Kyung;Kim, Cho Long;Kim, Ka Ram;Kang, Min Hye;Lim, Jeong Ae;Woo, Nam Sik;Rhee, Ka Young;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.31 no.4
    • /
    • pp.244-252
    • /
    • 2018
  • C-arm fluoroscopy is useful equipment in interventional pain management because it helps to guide correct needle targeting for the accurate injection and drug delivery. However, due to increased use of C-arm fluoroscopy in various pain procedures, the risk of radiation exposure is a significant concern for pain physicians. The harmful biological effects of ionizing radiation on the human body are well known. It is therefore necessary to strive to reduce radiation exposure. Lead aprons with thyroid shields are the most fundamental radiation protective devices for interventional procedures, and are very effective. However, the operator's radiation safety cannot be guaranteed because pain physicians seem to lack sufficient interest, knowledge, and awareness about radiation safety. Also, inappropriate care and use of radiation protective devices may result in a higher risk of radiation exposure. The purpose of this article was to review the literature on radiation safety with a focus on lead aprons and thyroid shields and present recommendations related to those devices during C-arm fluoroscopic-guided interventions by pain physicians.

Health Status and Improvement Measures for Irregular Plant Construction Workers at Yeosu National Industrial Complex (여수지역 비정규직 플랜트 건설 근로자의 안전보건 실태와 개선방안)

  • Choi, Sangjun;Kim, Shin-Bum
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.182-194
    • /
    • 2009
  • This study was conducted to evaluate health status and to propose health protection measures of irregular plant construction workers in Yoesu National Industrial Complex (YNIC). The status of safety and health management was examined in five areas including safety and health education, work environment monitoring, health examination, health management record, and personal protective equipment (PPE) for plant construction workers. The safety training rate for plant construction workers was reached high at 91%, The training was mostly consisted of safety accident related things, but training on hazardous materials was found to be insufficient. Workplace monitoring results showed that the compliance rate for work environment for irregular construction workers was 54% and workplace monitoring during turnaround (TA) period with high risk of exposure to hazardous agents has not been implemented. While 61.4% of irregular workers received the general health examination but only 36.8% received the special health examination. The special health examination was found to be conducted only upon welders from 2-3 years ago. The issue of health management record upon irregular construction workers was not being implemented. In case of PPE, basic safety protective equipments such as safety shoes, safety belt, safety helmet were being supplied well while the supply rate of respirator for organic vapor was relatively low at 40%. Based on this study, two suggestions to maximize the utilization of the current safety and health program were made while boosting its effectiveness in protecting workers' health. First, the role of owners (petrochemical plant) related to safety and health should be strengthened. Second, in consideration of the characteristics of construction workers who usually engage in short term employment and frequent movement, community based health management organization is suggested that can overcome such structural problem and carry out the implementation of health examination and sustained health management.

Analysis on operation characteristics and power burdens of the double quench trigger type SFCLs

  • Lim, Seung-Taek;Lim, Sung-Hun;Han, Tae-Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.33-37
    • /
    • 2017
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. The capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system operator need a counter-measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as effective solutions to reduce the fault current. For the above reasons various type SFCLs have been studied recently. In this paper, operation characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. Another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

A Study on the Supply and Perception of Personal Protective Equipments for Fire Fighters (화재진압대원의 개인보호장구 지급 실태 및 인식에 관한 연구)

  • Choi, Jaehyeong;Kim, Woojae;Kang, Shinwook;Kim, Junggon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • In this study, we surveyed the supply and perception of Personal Protective Equipments for firefighters. As a result, most of the respondents answered that they were paid in accordance with the supply standard, but 12% of the respondents said that there were insufficient equipment. Also, satisfaction with the performance of the equipment is mostly satisfied, but the safety gloves are more than 50% dissatisfied. In summing up the results of the survey, it is urgently necessary to improve the current supply standard, which is determined by the life of PPE, to the replacement period according to the using time or frequency. Also, a new standard should be prepared through the follow - up study.

Double quench and fault current limiting characteristics due to winding ratio of transformer type SFCL with third winding

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.38-42
    • /
    • 2019
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. And capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system need a counter measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as an effective solutions to reduce the fault current. For the above reasons various type SFCL is studied recently. In this paper, the operational characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. And another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device (3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정)

  • Lee, Mun Hyung;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

4M 방식에 의한 화학실험실 위험성 평가 기법

  • Kim, Jong-In;Lee, Dong-Ho
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.11-18
    • /
    • 2008
  • This research modified the checklist used in the universities in USA, England and Korea considering the current situation of Korea, and conducted case studies upon each section of appointed chemical laboratories based on 4M criteria, which stands for Machine, Media, Man and Management. The purpose of the studies is to assess how dangerous the laboratories are and to contribute to prevention of accidentsin the laboratories as well as reducing loss of lives and property. The result of this research found out the harmful and hazardous factors based on the 4M-type checklist and predicted the dangerousness as it multiplies possible frequency by intensity. Protective equipment, safety facilities in laboratories, emergency exit and compressed gas cylinder are found to be more dangerous, so the result shows that it is desirable to improve ventilation, safety facilities and circumstances of the laboratory through the investment.

  • PDF

Laser Safety in Laryngeal Microsurgery Using $CO_2$Laser (후두미세수술에서 탄산가스 레이저를 이용한 레이저 수술의 안전성)

  • 이정구;정필상;정필섭
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.159-164
    • /
    • 1998
  • The developmental and subsequent addition of laser technology to existing surgical techniques offered new and exciting Possibilities for improving traditional endoscopic operations and expanding the scope of the specialty of otolaryngology-head and neck surgery. Lasers were found to be Precise, but potentially dangerous, surgical instruments whose use was associated with certain distinct and unprecedented advantages, but also with many unique and potentially serious, and sometimes catastrophic complications. The Purpose of this study was to evaluate the of elation technique of $CO_2$laser, kinds of anesthesia, equipments of operating room, and education of medical staff. Four hundreds 4 cases of $CO_2$laser laryngeal microsurgery were reviewed for the safety of $CO_2$laser in laryngeal microsurgery. Vocal polyp (46,3%) was the most common pathology in our cases. The others were vocal nodule, Reinke`s edema, epiglottic cyst, laryngeal granuloma, laryngeal papilloma, intracordal cysts, laryngeal tuberculosis, laryngeal web, laryngotracheal stenosis, and laryngeal cancer. Following complete equipment controls, treatment area controls, maintenance, service and procedural controls, personel protective equipment, and warning signs, no complications were found in our cases. In conclusion, laryngeal microsurgery with $CO_2$laser could be done safely without complication if complete preoperative preparation and education of medical staff preceded.

  • PDF

Environmental Hazardous Assessment on Wood Panel Manufacturing Process (목재판넬 제조공정의 환경위험성평가)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.