• Title/Summary/Keyword: Safety measure time

Search Result 428, Processing Time 0.024 seconds

Relation between Multiple Markers of Work-Related Fatigue

  • Volker, Ina;Kirchner, Christine;Bock, Otmar L.
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • Background: Work-related fatigue has a strong impact on performance and safety but so far, no agreed upon method exists to detect and quantify it. It has been suggested that work-related fatigue cannot be quantified with just one test alone, possibly because fatigue is not a uniform construct. The purpose of this study is therefore to measure work-related fatigue with multiple tests and then to determine the underlying factorial structure. Methods: Twenty-eight employees (mean: 36.11; standard deviation 13.17) participated in five common fatigue tests, namely, posturography, heart rate variability, distributed attention, simple reaction time, and subjective fatigue before and after work. To evaluate changes from morning to afternoon, t tests were conducted. For further data analysis, the differences between afternoon and morning scores for each outcome measure and participant (${\Delta}$ scores) were submitted to factor analysis with varimax rotation and each factor with the highest-loading outcome measure was selected. The ${\Delta}$ scores from tests with single and multiple outcome measures were submitted for a further factor analysis with varimax rotation. Results: The statistical analysis of the multiple tests determine a factorial structure with three factors: The first factor is best represented by center of pressure (COP) path length, COP confidence area, and simple reaction time. The second factor is associated with root mean square of successive difference and useful field of view (UFOV). The third factor is represented by the single ${\Delta}$ score of subjective fatigue. Conclusion: Work-related fatigue is a multidimensional phenomenon that should be assessed by multiple tests. Based on data structure and practicability, we recommend carrying out further studies to assess work-related fatigue with manual reaction time and UFOV Subtest 2.

Availability Measures for Repairable Dynamic Reliability Models (수리 가능한 동적 신뢰도 모델의 가용도 척도)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.253-264
    • /
    • 2006
  • This paper is to derive three reliability and eight maintainability measures after organizing total time. I propose inherent availability,.achieved availability and operational availability with the new and useful reliability and maintainability measures above. Especially, inherent availability measure extends the repairable system reliability models.

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

A Study on New Measurement of Derailment Coefficient for Rolling Stocks (철도차량의 새로운 탈선계수 측정방법에 관한 연구)

  • Hong, Yong-Ki;You, Won-Hee;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.306-312
    • /
    • 2007
  • The running safety of rolling stock is assessed by derailment coefficient. It requires lots of preparatory time, expenditure and high measurement technique to measure derailment coefficient. If derailment coefficient could be measured when track or vehicle is maintained, safety will be improved. The measurement and assessment of running safety is necessary for safety especially for the vehicles newly developed and started service. Therefore measurement of derailment coefficient is most important thing to secure running safety. In this paper, we examined new assessment method which could estimate derailment coefficient by measuring vibration acceleration and displacement of vehicle operating at actual track irrespective of time and place. The new method could be used effectively as a mean confirming running safety.

  • PDF

A Case Study on the Six Sigma Application to Reduce Waiting Day for Computed Tomography in the Radiology Department (영상의학과 전산화단층촬영 검사 대기일 단축을 위한 6-시그마 적용사례 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.225-230
    • /
    • 2010
  • The purpose of the study was to apply and to expand the six sigma to reduce waiting times for computed tomography (CT) examination which manipulated by the department of radiology. It was preceded by DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, it wereselected for total 5 critical to quality (CTQ), which were the kindness, the waiting time, the examination explanation, the waiting day and the waiting stand environment, that increased the reserved time of CT examination. In the stage of measurement, the number of examinations and of reservation waiting days performed and resulted in final CTQ(Y) which measured each 1.68 and 1.85 sigma. In the stage of analysis, the examination concentrated on morning time, non-scheduled examination of the day, the delayed time of booking, frequent telephone contacting and equipment malfunction were determined as variable key causes. In the stage of improvement, it were performed with expansion of the examination in the morning time, integration of laboratories that used to in each steps, developing the ability of simultaneous booking schedule for the multiple examinations, developing program of examination request, and the customer management team operations. For the control, the number of examinations and reserved waiting days were measured each 3.14 and 1.13 sigma.

A Study on the Performance Improvement for Magnetic Resonance Imaging Examination by Using the 6-Sigma Application (6-시그마 기법을 이용한 자기공명영상 검사 실적 개선에 대한 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.243-249
    • /
    • 2011
  • The purpose of the study was to improve of performance for Magnetic Resonance Imaging (MRI) examination in the department of radiology. It was performed DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, The fifth kinds of CTQ (critical to quality) by the kindness, the waiting time, the examination explanation, the waiting time and the waiting environment were selected by voice of customer. In the stage of measurement, the performed examinations and the reservation waiting time were measured each 1.77 and 1.69 sigma. In the stage of analysis, the potential key causes were determined the limited working hours and the difference of examination time of various entries. In the stage of improvement, MRI were performed with the operating system of 24 hours examination and the optimization of the difference of examination time by among of 30 minutes, 40 minutes, 50 minutes. Finally, the number of examinations and reserved waiting days were measured by each 3.17 and 1.71 sigma in the control stage.

A Study on Risk Assessment and Risk Mitigation Measures of Liquefied Chlorine Leak (액화염소 누출의 위험도 분석 및 위험경감조치에 대한 연구)

  • Lee, Ju-Youn;Chon, Young-Woo;Hwang, Yong-Woo;Lee, Ik-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • As the chemical industry becomes more advanced, the awareness of chemical accidents is rising, and legal systems for chemical safety management are strengthened. In this study, quantitative risk assessment of liquid chlorine leak was conducted. Risk assessment was performed in the order of frequency analysis, consequence analysis, and risk calculation. The individual risk was presented in the form of contour lines. The social risk was expressed by the FN curve. The risk of day and night was in an unacceptable area, so it was required to mitigate risk. Therefore in-building, which could trap the pool, was selected as a risk mitigation measure. As a result of the cost benefit analysis, it was concluded that this measure should be reasonably implemented.

A Study on Improvement of Submarine Torpedo Acoustic Counter Measure Launcher System Safety Device Performance (잠수함용 어뢰기만기 발사체계 안전장치 작동성능 향상에 관한 연구)

  • Chang, Ho-Seong;Seo, Dae-Su;Lee, Gyeong-Chan;Lee, Jong-Gwan;Jo, Byeong-Gi;Kim, Joong-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.411-424
    • /
    • 2018
  • Purpose: The purpose of this study is to improve submarine TACM launcher system safety device performance. Methods: In this study, EPLD(Electrically Programmable Logic Device) control and time sharing method to the safety device actuator motor and discrete signal processor in launch control panel were used to resolve unusual performance of safety system. Results: The result of this study are as follows; First, sporadic stopping of safety device actuator motor due to insufficient In-Rush current was resolved. Second, repeat of safety device condition as lock & release due to chattering for motor activating was resolved. Third, simultaneous release function for safety device actuator was available. Conclusion: The unusual performance of function for submarine TACM launcher system was overcame by applying EPLD control and time sharing method. The suggestions were proved by performance test in the pressure chamber. The results of this study enhanced survivability of ${\bigcirc}{\bigcirc}{\bigcirc}$ class submarine from enemy torpedo.

Improving the Workplace Experience of Caregiver-Employees: A Time-Series Analysis of a Workplace Intervention

  • Ding, Regina;Dardas, Anastassios;Wang, Li;Williams, Allison
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.296-303
    • /
    • 2021
  • Background: Rapid population aging in developed countries has resulted in the working-age population increasingly being tasked with the provision of informal care. Methods: An educational intervention was delivered to 21 carer-employees employed at a Canadian University. Work role function, job security, schedule control, work-family conflict, familywork conflict, and supervisor and coworker support were measured as part of an aggregated workplace experience score. This score was used to measure changes pre/post intervention and at a follow-up period approximately 12 months post intervention. Three random intercept models were created via linear mixed modeling to illustrate changes in participants' workplace experience across time. Results: All three models reported statistically significant random and fixed effects intercepts, with a positive coefficient of change. Conclusion: This suggests that the intervention demonstrated an improvement of the workplace experience score for participants over time, with the association particularly strong immediately after intervention.

A Study on Minimum Ignition Energy by Controlled Discharge Energy (방전에너지 제어에 의한 최소점화에너지의 고찰)

  • Choi, Sang-Won;Ohsawa, Atsushi
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.36-39
    • /
    • 2007
  • It is important to know Minimum Ignition Energy(MIE) of flammable materials for ignition hazard of chemical processes etc.. Currently a capacitor discharge is used mainly to measure the MIE. Then, it is impossible to control actively discharge energies and discharge time because the MIE measurement uses a high voltage capacitor and fixed capacitor. However, the control of discharge energy and discharge time will be convenient if self-sustain discharge is used. In this paper, we measured the MIE by self-sustain discharge of a pulse shape to propose the new measuring method of the MIE. AS a result, ignition energies are increased gradually as discharge duration time gets longer, and discharge current grows larger. Also, an arc discharge and a glow discharge occurred during the experimental period, and the ignition by glow discharges happened when discharge duration time was $90{\mu}s$, discharge current was 8A and 1A Especially, the MIE occurred the 0.05mm and 0.08mm of the gap distance between discharge electrode in the same discharge duration time.