• Title/Summary/Keyword: Safety gloves

Search Result 105, Processing Time 0.021 seconds

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

Analysis of the Importance-Performance Related service management and feeding practices of teachers at mealtime in childcare centers (어린이집 보육교사의 배식관리 및 식사지도에 대한 중요도-수행도 분석)

  • Yeoh, Yoonjae;Kwon, Sooyoun
    • Journal of Nutrition and Health
    • /
    • v.48 no.3
    • /
    • pp.289-297
    • /
    • 2015
  • Purpose: This study was conducted in order to determine the difference of Importance and Performance Related service management and feeding practices of teachers at mealtime in childcare centers. Methods: In December, 2013, questionnaires were completed by teachers working at childcare centers in Geumcheon-gu, Seoul. A total of 179 teachers responded to questions regarding perceived importance and degree of performing related service management and feeding practices at mealtime in childcare centers. Factor analysis and Importance-Performance Analysis (IPA) were used. Results: Four factors including 11 items were represented by factor analysis: 'Personal hygiene management', 'Feeding practice', 'Food material management', and 'Service at serving foods'. For 'Personal hygiene management', scores for perception on importance and performance were 4.42 and 3.84 points of 5 that were the lowest among factors. As a result of IPA, teachers were aware of the importance and performed well, 'Encouraging and praising children's eating habits at mealtime', 'Giving thanks before and after a meal', and 'Sitting and eating with children at mealtime' belonged to 'Feeding practice'; whereas they were not aware of the importance and performed insufficiently, 'Wearing the hygiene hat for serving foods', 'Wearing disposable gloves for serving foods', and 'Wearing the apron for serving foods' belonged to 'Personal hygiene management'. Conclusion: For children's health and safety in foodservice at childcare centers, personal hygiene management is very important when cooking as well as serving food. The results suggest that education targeting personal hygiene management is necessary for management of hygiene by teachers while serving food in childcare centers. In addition, guidelines on service management and feeding practice are needed for teachers working at childcare centers.

A Survey of the Basic Protection Manners of Dental Personnels Against Hepatitis B in and around Seoul (수도권 치과의료 종사자들의 B형 간염에 대한 기초방호실태 및 수행에 관한 조사)

  • Yoon, Mi-Sook;Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 2001
  • The purpose of this study was to examine dental personnels' concern for health, their personal protection manner, and whether or not they were inoculated against hepatitis B and made an inquiry of patients about that. It's ultimately meant to serve as a basis for the preparation of an anti-infection guide for the protection of dental personnels against all sorts of infectious diseases. After a survey was conducted from March 29 through May 9, 2001, the following findings were obtained: (1) The dental personnel group that had worked for 5 to less than 7 years took health examination the most, with 71.4%, before joining the hospital, and 61.5% of those who had served for 9 years or more, the greatest percentage, took medical checkup after joining the hospital(P<0.05). (2) The largest percentage of being inoculated against the anti-B type hepatitis after employment was 71.4% of the dental personnels over 35, and 57.7% of those with 9-year or more working experiences. Therefore, their age and service term made a significant difference(P<0.05). (3) There was no significant gap in personal protection practices between the dental hygienists and nurse aids(P>0.05). But the use of safety goggles for treatment was not properly done, with just 1.48 on the basis of 3 points, whereas the use of mask was scored 2.40 and the use of gloves was scored 1.96. (4) After a narcotic was used once, the leftovers were wasted by 89.7% of the dental hygienists and 70.0% of the nurse aids. More dental hygienists wasted them(P<0.05). (5) For hand washing, antibiotic liquid soap was used by 19.3% of the dental hygienists and 10.0% of the nurse aids, which were both very low percentage. And just 37.2% of the dental hygienists utilized a disposable paper towel to dry their hands, and only 36.0% of the nurse aids used the same(P<0.05).

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Risk Assessment of Operator Exposure During Treatment of Fungicide Dithianon on Apple Orchard (사과 과수원에서 농약살포시 살균제 Dithianon의 농작업자 위해성 평가)

  • Cho, ll Kyu;Kim, Su Jin;Kim, Ji Myung;Oh, Young Goun;Seol, Jae Ung;Lee, Ji Ho;Kim, Jeong Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.302-311
    • /
    • 2018
  • BACKGROUND: Dithianon (75%) formulation were mixed and sprayed as closely as possible by normal practice on the ten farms located in the Mungeong of South Korea. Patches, cotton gloves, socks, masks, and XAD-2 resin were used for measurement of the potential exposure of dithianon on the applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to dithianon during preparation of spray suspension and application with a power sprayer on a apple orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump, IOM sampler and cassette, and glass fiber filter was used for inhalation exposure. The field studies were carried out in a apple orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 85.1% and 99.1% in the level of 100 LOQ (limit of quantification), while the LOQ for dithianon was $0.05{\mu}g/mL$ using HPLC-DAD. The exposure to dithianon on arms of the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, or legs). The exposure to dithianon on the applicator's legs (3.78 mg) was highest in the body parts. The dermal exposures for mixer/loader and applicator were 10 and 8.10 mg, respectively, from a grape orchard. The inhalation exposure during application was estimated as 0.151 mg, and the ratio of inhalation exposure was 11.2% of the dermal exposure (inner clothes). CONCLUSION: The dermal and inhalation exposure on the applicator appeared to be 4.203 mg - 25.064 mg and $0.529{\mu}g-116.241{\mu}g$, respectively. The total exposures on the agricultural applicators were at the level of 2.596 mg - 25.069 mg to dithianon during treatment for apple orchard. The TER showed 3.421 (>1) when AOEL of dithianon was used as a reference dose for the purpose of risk assessment of the mixing/loading and application.