• Title/Summary/Keyword: Safety device

Search Result 1,824, Processing Time 0.031 seconds

The development of buoy type fish finder using LTE communication (LTE 통신을 이용한 부표형 어군탐지기 개발)

  • KANG, Tae-Jong;MIN, Eun-Bi;HEO, Gyeom;SHIN, Hyeon-Ok;HWANG, Doo-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.141-152
    • /
    • 2022
  • As a method to understand the ecological habits around the artificial reef, various reports such as fishing gear survey, diving, sound survey, underwater CCTV and camera, etc. are reported. Among them, the sound survey method is carried out by installing an acoustic system on the ship and can be investigated regardless of the marine environment such as time constraints and turbidity. Such method, however, takes a lot of manpower and time as the ship travels at a constant speed. Investigations around artificial reefs are being conducted in an artificial way, and a lot of time and labor are consumed as such. Maritime buoys have been operated for various purposes such as route signs, weather observation, marine environment monitoring and defense monitoring for navigation safety in the past, but studies on monitoring systems for ecological habits and distribution of fish using marine buoys are remarkably insufficient. Therefore, this study aims to develop a system that allows users to directly monitor fish group detector data by estimating the distribution of fish groups around artificial reefs and using wireless communication at sea. In order to confirm the suitability of the maritime buoy used in this study, it was operated to compare data using LTE-equipped buoys capable of wireless communication and a data logger-type system buoy. Data transmission of buoys capable of LTE communication was carried out in a 10-minute ON, 10-minute OFF method due to the limitation of the power supply capacity, and data of the data logger-type buoy received full data. We compared and analyzed the data received from the two fish detectors. It is expected that real-time monitoring of the wireless buoy detection device using LTE will be possible through future research.

Study on Visual Communication Design of Wearable Computing Devices (웨어러블 컴퓨팅 디바이스를 이용한 시각 디자인 구현 및 연구)

  • Lee, Su Jin
    • Korea Science and Art Forum
    • /
    • v.34
    • /
    • pp.251-262
    • /
    • 2018
  • The purpose of this study is to understand how wearable computing devices are designed and how to design them in a technology based wearable device design research. Research is premised on the consideration of producers and consumers. There is wearable computer of eyeglasses, watches, clothes, and so on. The user can always wear these products comfort and use as part of the body without any sense of discomfort, and the goal is to supplement or double the ability of the human being. It should be easy to use them convenient, wear comfortable, safe and sociable at any time. For the satisfaction these conditions, the wearable computing devices have several factors. There are technical performances, visual aesthetics, Human body system and devices communication and safety. Furthermore, these factors have to match to operating system, real-time operating system and applied software. To comprehend wearable computing devices should be offered the design of the both software and hardware designed.

Characterization of X-ray Emitted in the Ion Implantation Process of Semiconductor Operations (반도체 제조 이온주입 공정의 이온 임플란타 장치에서 엑스레이 발생 특성)

  • Dong-Uk Park;Kyung Ehi Zoh;Soyeon Kim;Seunghee Lee;Eun Kyo Jeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.439-446
    • /
    • 2023
  • Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.

Development of a Web Platform System for Worker Protection using EEG Emotion Classification (뇌파 기반 감정 분류를 활용한 작업자 보호를 위한 웹 플랫폼 시스템 개발)

  • Ssang-Hee Seo
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.37-44
    • /
    • 2023
  • As a primary technology of Industry 4.0, human-robot collaboration (HRC) requires additional measures to ensure worker safety. Previous studies on avoiding collisions between collaborative robots and workers mainly detect collisions based on sensors and cameras attached to the robot. This method requires complex algorithms to continuously track robots, people, and objects and has the disadvantage of not being able to respond quickly to changes in the work environment. The present study was conducted to implement a web-based platform that manages collaborative robots by recognizing the emotions of workers - specifically their perception of danger - in the collaborative process. To this end, we developed a web-based application that collects and stores emotion-related brain waves via a wearable device; a deep-learning model that extracts and classifies the characteristics of neutral, positive, and negative emotions; and an Internet-of-things (IoT) interface program that controls motor operation according to classified emotions. We conducted a comparative analysis of our system's performance using a public open dataset and a dataset collected through actual measurement, achieving validation accuracies of 96.8% and 70.7%, respectively.

A Comparative Study on the Regulations on Implantable Bioabsorbable Combination Products -Focusing on the U.S., Europe and Korea- (이식형 흡수성 융복합 의료제품 규제 비교 연구 -미국, 유럽, 한국을 중심으로-)

  • Hyeon Jeong Lee;Mi Hye Kim;Ju Eun Seol;Su Dong Kim;Joo Hee Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.414-427
    • /
    • 2023
  • Implantable bioabsorbable combination products undergo inherent degradation and systemic absorption within the physiological environment, thereby streamlining the therapeutic regimen and obviating the imperative for invasive extraction procedures. This inherent property not only enhances patient convenience and therapeutic efficacy but also underpins a paradigm of support characterized by heightened safety parameters. Within the regulatory landscapes of Korea, the United States, and Europe, implantable bioabsorbable combination products are meticulously classified into distinct categories, either as pharmaceutical implants or as implantable medical devices, depending on their primary mode of action. This scholarly investigation systematically examines the regulatory frameworks governing implantable bioabsorbable combination products in South Korea, the United States, and Europe. Notable discrepancies across national jurisdictions emerge concerning regulatory specifics, including terminology, product classification, and product name associated with these products. The conspicuous absence of standardized approval regulations presents a formidable barrier to the commercialization of these advanced medical devices. This academic discourse passionately emphasizes the critical need for formulating and implementing a sophisticated regulatory framework capable of streamlining the product approval process, thereby paving the way for a seamless path to commercializing implantable bioabsorbable combination products.

Surgical Resection of Cardiac Hemangiosarcoma Using Articulated Surgical Stapler in a Dog

  • Woo-Jin Kim;Kyung-Min Kim;Won-Jong Lee;Chang-Hwan Moon;Hae-Beom Lee;Seong-Mok Jeong;Dae-Hyun Kim
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • This case report discusses the successful surgical resection of cardiac hemangiosarcoma in a dog using an articulated surgical stapler. Cardiac tumors, particularly hemangiosarcomas, have a poor prognosis. Recommended treatment involves surgical removal of the primary tumor, along with chemotherapy. However, the use of staples for cardiac tumor resection has not yet been extensively documented in the veterinary literature. A 10-year-old dachshund with pericardial effusion underwent surgery to remove a right atrial mass. An articulated linear cutting stapler was used for tumor resection. The patient experienced chylothorax as a complication but recovered well. However, the patient later developed respiratory symptoms and died, most likely due to aspiration pneumonia. The surgical stapler provided stability, convenience, and a shorter surgical time during tumor resection. Surgical resection combined with chemotherapy improves the survival of dogs with cardiac hemangiosarcoma. The stability and adjustability of the stapling device make it advantageous for cardiac tumor resection. Although complications, such as chylothorax, can arise, appropriate management can lead to positive outcomes. This case report demonstrates the feasibility and safety of using an articulated surgical stapler for cardiac tumor resection in dogs. Insights from this case can guide future research and clinical practice.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

A Bibliometric Analysis of Research Trends in Domestic Integrative Medicine Journals : Focused on Integrative Medicine Research (국내 통합의학 저널의 연구 동향에 대한 계량서지학적 분석 : Integrative Medicine Research를 중심으로)

  • Dae-Jin Kim;Tae-Hyung Yoon;Jong-Rok Lee;Byung-Hee Choi
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.197-210
    • /
    • 2024
  • Purpose : This study aimed to analyze research trends in the field of integrative medicine through a bibliometric analysis of articles published in Integrative Medicine Research (IMR) journal from 2017 to 2022. Methods : Articles published in IMR journal between 2017 and 2022 were searched using the Web of Science database on August 22, 2023. The analysis was performed using the Bibliometrix and Biblioshiny tools in R (version 4.3.1) and VOSviewer (version 1.6.19). Results : The key findings were as follows: average citations per article (9.41), total authors (1,142), single-authored articles (12), average articles per author (0.27), average co-authors per article (5.27), and rate of international co-authorships (15.69 %). The most-cited article was on the cryopreservation of cells or tissues and their clinical applications. The top keyword analysis by author keywords showed that "acupuncture" was the most frequently used keyword (33 times). Co-occurrence network analysis showed 85 high-frequency keywords that appeared five or more times, and the top five keywords by total link strength were "acupuncture," "herbal medicine," "prevalence," "alternative medicine," and "complementary." The study found that, contrary to the trend in complementary and alternative medicine research in Korea, the IMR journal actively conducts intervention studies to provide clinical evidence. Conclusion : In the IMR journal, "acupuncture" was the most frequent of author keywords. The analysis of keyword trend topics over time showed that the keyword "systematic review" continued to appear from 2020 to 2022, and the keyword "clinical practice guideline" appeared for the first time in 2021. In particular, the co-occurrence network analysis highlighted keywords related to intervention research, in contrast to domestic research trends. While this study analyzed only one journal, future studies expanding the category of integrative medicine and increasing the number of journals analyzed may provide further insights.

Integrity Guarantee System in IoT Virtual Environment Platform: Through Hyperedfger Indy and MQTT (IoT 가상환경 플랫폼에서의 무결성 보장 시스템:Hyperledger Indy와 MQTT를 통하여)

  • Yoosung Hong;Geun-Hyung Kim
    • Smart Media Journal
    • /
    • v.13 no.4
    • /
    • pp.76-85
    • /
    • 2024
  • In this paper, we propose a system that improves the data integrity of IoT(Internet of Things) devices in the virtual environment by combining Hyperledger Indy and MQTT(Message Queuing Telemetry Transport). The system complements the limitations of the centralized system by realizing a DPKI(Decentralized Public Key Infrastructure) structure that utilizes a distributed network in publish-subscribe(pub/sub) pattern communication. Digital signature technology was applied to ensure the data integrity of IoT devices and communication scenarios between the four core components of the client, IoT device, broker, and blockchain, as well as a topic structure using a decentralized identifier to ensure safety in the virtual environment. We present a systematic method for transparent data exchange. To prove the performance of the proposed system, this paper conducted experiments on four scenarios and evaluated communication performance in a virtual environment. The experimental results confirmed that the proposed system provides a reliable IoT data communication structure in a virtual environment.

Impact of a simple non-invasive nasal mask device on intraprocedural hypoxemia in overweight individuals undergoing upper gastrointestinal endoscopy with sedation provided by a non-anesthesiologist provider

  • Jan Drews;Jonas Harder;Hannah Kaiser;Miriam Soenarjo;Dorothee Spahlinger;Peter Wohlmuth;Sebastian Wirtz;Ralf Eberhardt;Florian Bornitz;Torsten Bunde;Thomas von Hahn
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.196-202
    • /
    • 2024
  • Background/Aims: Hypoxemia is a common side effect of propofol sedation during endoscopy. Applying mild positive airway pressure (PAP) using a nasal mask may offer a simple way to reduce such events and optimize the conditions for diagnostic and therapeutic upper gastrointestinal endoscopies. Methods: We compared overweight patients (body mass index >25 kg/m2) with a nasal PAP mask or standard nasal cannula undergoing upper gastrointestinal endoscopies by non-anesthesiologists who provided propofol sedation. Outcome parameters included the frequency and severity of hypoxemic episodes. Results: We analyzed 102 procedures in 51 patients with nasal PAP masks and 51 controls. Episodes of hypoxemia (oxygen saturation [SpO2] <90% at any time during sedation) occurred in 25 (49.0%) controls compared to 8 (15.7%) patients with nasal PAP masks (p<0.001). Severe hypoxemia (SpO2 <80%) occurred in three individuals (5.9%) in both groups. The mean delta between baseline SpO2 and the lowest SpO2 recorded was significantly decreased among patients with nasal PAP mask compared to controls (3.7 and 8.2 percentage points difference, respectively). There were significantly fewer airway interventions performed in the nasal PAP mask group (15.7% vs. 41.2%, p=0.008). Conclusions: Using a nasal PAP mask may be a simple means of increasing patient safety and ease of examination.