• Title/Summary/Keyword: Safety check

Search Result 943, Processing Time 0.021 seconds

Development of smart HACCP effectiveness analysis model (스마트 HACCP 효과 분석 모델 개발)

  • Lee, Han-Cheol;Kang, Ju-Yeong;Park, Eun-Ji;Park, Min-Ji;Oh, Do-Gyung;Kim, Chan-Yeong;Jeong, Eun-Sun;Kim, Jai-Moung;Ahn, Yeong-Soon;Kim, Jung-Beom
    • Food Science and Industry
    • /
    • v.54 no.3
    • /
    • pp.184-195
    • /
    • 2021
  • Smart HACCP is a system that can check the monitoring of critical control point (CCP) in real time to implement improvement measures immediately after departure from limit criteria and prevent falsification of data by digitizing handwritten records. In this study, we developed the analysis model for the effectiveness ofsmart HACCP to compare and analyze with existing HACCP. By introducing of smart HACCP system, the evaluation index value of HACCP effectiveness for HACCP-certificated companies on a small scale increased by 9.25 points, corresponding to 11.52% of increase rate. General HACCP-certificated companies showed 4.52 point and 5.00% of increase rate by introducing of smart HACCP system. Thus, it was confirmed that the introduction of smart HACCP system contributes to the improvement of food safety management and especially it would be more effective for HACCP-certificated companies on a small scale than general HACCP-certificated companies.

An Experimental Study on the Noise Reduction of Cooling Fans for Four-ton Forklift Machines (4톤급 지게차 냉각홴 소음 저감에 관한 실험적 연구)

  • Choi, Daesik;Kim, Seokwoo;Yeom, Taeyoung;Lee, Seungbae
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • This paper presents research on methods for the reduction of forklifts' noise level for the increased comfort and safety of its operator. A cooling fan with a high air volume flow rate installed in the forklift acts as an important design parameter which efficiently cools the heat exchanger system, helping to transfer internal heat from the engine room to the outdoors with both transmitted and diffracted opening noises. The cooling fan contributes significantly to both the forklift's emitted sound power and the operator room's noise level, thereby necessitating research on the forklift's reduction of acoustic power level and transmission. A noise analysis for various fan models with a biomimetic design based on eagle-wing geometry was conducted. In addition to the acoustic power generation, the aerodynamic performance of the cooling blade is also strongly influenced by the design of airfoil distribution, thereby requiring optimization. The cooling fans were fabricated and installed in the forklift in order to check the efficacy of the forklift engine's cooling, and the final version of the fan was measured for its ability to lower acoustic power level and cool the engine room. This study explains the aerodynamic and acoustic features of the designed fans with the use of BEM analysis and forklift test results.

Efficacy of live NNV immersion vaccination in three grouper species (Seven band grouper Hyporthodus septemfasciatus, Red spotted grouper Epinephelus akaara, Long tooth grouper Epinephelus bruneus) (바리과 어류 3종(능성어 Hyporthodus septemfasciatus, 붉바리 Epinephelus akaara, 자바리 Epinephelus bruneus)에 대한 신경괴사증바이러스(Nervous Necrosis Virus, NNV)의 생백신 처리 효과)

  • Kim, Si-Woo;Park, Jung-Jun;Hong, Chang-Gi;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.34 no.1
    • /
    • pp.99-104
    • /
    • 2021
  • In this study, we investigated safety and efficacy of a low temperature immunization protocol with NNV in red spotted grouper, Epinephelus akaara and long tooth grouper, Epinephelus bruneus and seven band grouper, Hyporthodus septemfasciatus. Further, growth rate between immunized and naïve fish was evaluated during the experiment to check side effect of immunization. Three grouper species were immunized by immersion method with live NNV at 105.0 TCID50/mL at 16.5℃ for 30 min and reared for 120 days at natural sea water temperature. To evaluate growth rate, total length and wet weight was measured 7 times after immunization. Immunized three grouper species were challenged by intramuscular inoculation with NNV at 104.2 TCID50/100 µL/fish. Immunization at low temperature with live NNV did not show any clinical symptoms of infection, mortality and inhibition of growth. After challenge, cumulative mortality of naïve seven band grouper, red spotted grouper, long tooth grouper were 45, 10, 20 %, respectively. However no mortality was observed at immunized groupers. Thus, it was demonstrated that immunization at low temperature with live NNV are able to protect three different species of groupers without inhibition of growth.

Jacking Force and Camber for Precast Concrete Slab Reinforcing (프리캐스트 콘크리트 슬래브 보강을 위한 잭킹력과 솟음)

  • Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.43-48
    • /
    • 2021
  • Precast concrete can be used to reduce construction period and enhance construct ability. However structural problems could be occurred due to the wrong application of boundary condition and misunderstanding of structural behavior in the process of segmentation of original structure system. I experienced a serious deflections and cracks due to the increase of bending moment and creep after the construction of precast concrete slab, and we learned that this is from the misunderstanding of support conditions and structure behaviors of precast slab panel. Two support columns under the precast slab are inserted to reduce the bending moment, and the camber according to jacking force should be estimated for the structural safety during the reinforcing work. A proper support condition and the flexural stiffness of precast concrete slab were applied to check the deflection and crack for existing structure by inverse analysis, and we can estimate the camber according to jacking force of the precast concrete slab, and suggest a method to make safe structure.

Development of Low-Cost High-Performance Antibacterial Tempered Glass (저비용 고기능성 항균강화유리 개발을 위한 연구)

  • Kim, Jun-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.562-567
    • /
    • 2021
  • To develop an antibacterial tempered glass for applications to various building facilities and household products, the antibacterial activity of domestic materials was investigated, and a tempered glass sample was produced with silver, copper, and zinc, having an antibacterial activity of 99% or more at a specific concentration. The measured antibacterial activity of the samples, in which silver, copper, and zinc were dispersed in ethylene glycol + glycerol, was more than 99%. Measurements of the thickness of the coated metal material by washing using a surface analyzer showed that the thickness decreased by less than 1% in various types of detergents, including water, but only approximately 10% in the alkaline detergents. To check the human safety of the samples, a cytotoxicity test was performed through an MTT assay; the samples showed no cytotoxicity. Finally, a Live/Dead kit or film adhesion method showed that the antibacterial activity of the prototype was more than 99%. Therefore, the high-functional antibacterial effect of tempered glass was developed using domestic materials and may be used in various products in the future.

Assessment of Covid-19 Response of the Medical Institutions Based on ISO Public Service Quality Management Framework (ISO 기반 공공서비스 품질관리 프레임워크를 바탕으로 한 의료기관의 COVID-19 대응 현황 평가)

  • Pyun, Jebum;Kim, Seungbeom
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.69-84
    • /
    • 2020
  • This study is conducted to improve the quality of healthcare services responding to COVID-19 by applying the public service quality management framework that is developed from ISO18091:2019 by the Ministry of the Interior and Safety of South Korea. The COVID-19 pandemic has been impacting the world since early 2020, and now in November 2020, it still has not been eliminated. The Korean medical institutions were able to prevent the spread of COVID-19 by agile test and strict cohort isolation. As a result, the so-called K-medical defense has achieved a positive reputation from around the world. In this study, we check and evaluate the current status of the COVID-19 response targeting some Korean hospitals by applying a quality control checklist based on the public service quality management framework. Status of 7 categories are analyzed based on the interview with 3 medical institutions. We also suggest improvements for better medical service quality in case of COVID-19 being prolonged.

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

Effect of tunnel fire: Analysis and remedial measures

  • Choubey, Bishwajeet;Dutta, Sekhar C.;Kumar, Virendra
    • Structural Engineering and Mechanics
    • /
    • v.80 no.6
    • /
    • pp.701-709
    • /
    • 2021
  • The paper aims at improving the understanding and mitigating the effects of tunnel fires that may breakout due to the burning fuel and/or explosion within the tunnel. This study particularly focuses on the behavior of the commonly used horse shoe geometry of tunnel systems. The problem has been obtained using an adequate well-established program incorporating the Lagrangian approach. A transient-thermo-coupled static structural analysis is carried out. The effects of radiation and convection to the outer walls of the tunnel is studied. The paper also presents the impact of the hazard on the structural integrity of the tunnel. A methodology is proposed to study the tunnel fire using a model which uses equivalent steel sheet to represent the presence of reinforcements to improve the computational efficiency with adequate validation. A parametric study has been carried out and the effect of suitable lining property for mitigating the fire hazard is arrived at. Detailed analysis is done for the threshold limits of the properties of the lining material to check if it is acceptable in all aspects for the integrity of the tunnel. The study may prove useful for developing insights for ensuring tunnel fire safety. To conduct such studies experimentally are tremendously costly but are required to gain confidence. But, scaled models, as well as loading and testing conditions, cannot be studied by many trials experimentally as the cost will shoot up sharply. In this context, the results obtained from such computational studies with a feasible variation of various combinations of parameters may act as a set of guidelines to freeze the adequate combination of various parameters to conduct one or two costly experiments for confidence building.

Development of a 3D Model-Based Demonstration DB System for Efficient Management and Utilization of Inspection and Diagnosis Data of Small and Medium-Sized Bridges (중소규모 교량의 점검·진단 데이터 효율적 관리 및 활용을 위한 3D 모델 기반 실증 DB시스템 개발)

  • Park, Se-Hyun;Jung, Dae-Sung;Seo, Jin-Sook;Kim, Tae-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.1-11
    • /
    • 2021
  • As the aging of large domestic SOC facilities accelerates, facility maintenance is also changing from safety evaluation based on the current condition to performance-oriented preventive and preemptive maintenance based on the prediction of the level of future obsolescence. In particular, in the case of bridges, class 1 and 2 bridges are systematically managed along with many studies, but for small and medium-sized class 3 bridges there is no collection and utilization of historical data presenting performance degradation during their service life. Therefore, in this study, 3D model-based demonstration DB system was designed and developed to intuitively check the damage change rate at the damage location by registering the maintenance history by life cycle for each member's exterior damage in the 3D bridge object and to enable API-based comprehensive performance evaluation.

Development of a Customized Beacon Equipped with a Strain Gauge Sensor to Detect Deformation of Structure Displacement (구조물의 변위 변형 감지를 위한 변형률 센서를 장착한 커스터마이징 비콘 개발)

  • Kim, Junkyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2021
  • This study attempted to detect possible collapse and fire accidents in facilities for disaster monitoring of large facilities, and to develop a customized beacon to recognize the internal situation of an IoT-based facility when a disaster occurs. In the case of data measurement using the existing strain gauge sensor, the strain gauge sensor was connected by wire to measure it, but this study changed it to wireless so that the presence and absence of structural deformation can be monitored in real time. In this process, in order to use the Wheatstone bridge, a strain sensor module that can be connected to a customized beacon was manufactured, and a system configuration was conducted to remotely check the measurement data. To verify measurement data, 10 customized beacons and 2 gateways were installed on the 15th floor of the Advanced Institue of Convergence Technology, and as a result of analysis of measurement data, it was confirmed that the strain data values were distributed between 7 and 8.