• 제목/요약/키워드: Safety Line

검색결과 1,933건 처리시간 0.047초

발전소 직류전선로의 지락안전진단 시스템에 관한 연구 (A Study on the Ground Fault Diagnosis System of Power Station DC Power line)

  • 안영주;김남호;이형기
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 1997
  • There are two kinds of ground fault diagonosis system(GFD), which are for AC and DC power line. The ground fault current of a DC power line Is, first, analyzed for a description of a GFD system for DC power line and then the construction method of the GFD system, which could be processed and analyzed a ground fault current, are explained. Main functions of the system are that the detected ground fault current could be converted to the line insulation resistance by a program and saved in the system memory continuously. Finally a DC power line insulation safety could be decide by a change of the saved Insulation resistance for a given time. This system can detect the ground fault resistance to 100㏀.

  • PDF

OLED display device의 Line Defect 시험법에 관한 연구 (A Study on OLED display device's line defect test methode)

  • 최영태;조재립
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 춘계학술대회
    • /
    • pp.523-529
    • /
    • 2009
  • The ACF(Anisotropic Conductive Film) is used for bonding Drive IC and OLED display device panel. If ACF bonding process is problem, a malfunction of line defect can occur. Because electric resistance increase between the panel and drive IC after a period of time, drive IC can not supply enough current to the panel. This paper is studied on a method of test for line defect.

  • PDF

재해분석을 통한 배전선로 활선작업 공종별 위험지수 평가 (The Assessment of the Risk Index of Live-line Works on Distribution Line by the Accident Analysis)

  • 최승동;현소영;한형주;신운철
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.8-14
    • /
    • 2011
  • The live-line works are very dangerous because of direct contacts with the distribution line or neighboring contacts. So the purpose of this study is to identify the risk factor by accident occurrence form and accident case analysis, and to suggest the quantified risk index by risk occurrence frequency and risk strength analysis. And the risk index assessment is researched by accident cases analysis on work type. Accident cases of transmission distribution line are researched based on data of the Ministry of Employment and Labor in the last ten-year period (2000~2009). In results of this paper, high risk isn't always a priority of safety measures. Risk occurrence frequency and risk strength have to be considered according to detail work types, work methods and conditions of field work. And safety management measures must be planned according to risk occurrence frequency and risk strength.

LOSA실행을 통한 운항 승무원 수행 분석 (The analysis of the line crew performance through the Line Operation Safety Audit (LOSA))

  • Choi, Jin-Kook;Kim, Chil-Young
    • 한국항공운항학회지
    • /
    • 제16권2호
    • /
    • pp.43-50
    • /
    • 2008
  • ICAO(International Civil Aviation Organization) Doc 9803의 국제규정에 의거하여 SMS(Safety Management System-안전관리시스템)의 대표적인 비행안전 모니터링 프로그램으로 인정된 신개념의 운항감사제도인 LOSA(Line Operations Safety Audit-항공운항 안전감사)를 항공사에서 실시하여 정상 운항시의 운항승무원을 관찰하여 실제의 안전취약 및 위협요소, Error를 포착하여 텍사스대학 인적요인 연구소에서 작성한 최종보고서의 분석을 통해 제도와 방안을 개선한다. 본 논문에서는 LOSA실행을 통한 승무원들의 위협 및 error의 유형과 발생율, 관리율 및 관리여부를 분석하여 설명하고 항공사내 개선인 SCP(Safety Change Process)를 소개하는데 있다.

  • PDF

기존선 곡선선로에서 한국형 틸팅열차의 속도향상시 주행안전성 평가 (Running safety evaluation of tilting vehicle when speed-up in curved track of conventional line)

  • 함영삼;이동형;권석진;서정원;전현규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.25-29
    • /
    • 2010
  • Safety of railroad is result of reliability which is received from test & evaluation of system. Railroad system is consisted of various sub system such as vehicle, supply of electric power, signal, communication, rail track construction, operation. To secure safety of railroad, evaluation about parts, assembly, sub system, whole system etc.. that compose railroad is essential. In this paper, I wish to describe for results that analyze korean tilting vehicle's derailment coefficient developed by national research achievement. Confirmed that is possible even if speed up, curved line department running speed that estimate korean tilting vehicle's running safety in curved line track of Jungang Line about 20 km/h than present operating speed.

  • PDF

통계적방법을 이용한 초고압 송전선의 전자계 특성 및 인체 안전에 관한 연구 (A Study on Characteristics and Safety for Human Body in ELF Electric and Magnetic Fields using Statistical Method)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.75-80
    • /
    • 1996
  • This paper presents a study on characteristics and safety for human body in ELF electric and magnetic fields using statistical method. The magnetic fields from a power line can be computed given a knowledge of the currents, voltage and geometry of the line. In this paper, a statistical method for predicting the magnetic fields given the inherent indetermination of the currents is presented. But the electric field is calculated given a knowledge of the voltage and geometry of the line. The effect of unexpected fluctuations in current is modeled by the Monte Carlo simulation. The suggested method is applied to the 345kV and 765kV transmission line system, the result shows that the maximum electric and magnetic field intensity is 6.8627kV/m and 284mG in 345kV system, 2. 5590kV/m and 35mG in 765kV system, respectively.

  • PDF

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

Man-Machine Chart를 이용한 조립라인의 생산성 향상 사례 연구 (A Case Study for Improving the Productivity of Assembly Line using Man-Machine Chart)

  • 정병용
    • 대한안전경영과학회지
    • /
    • 제5권4호
    • /
    • pp.187-194
    • /
    • 2003
  • The purpose of a man-machine chart is improved utilization of a man or a machine. Improved utilization can mean less idle time, rebalanced idle time, or less idle time of an excessive component. In this study we improved the productivity of the assembly line in the electronics company using man-machine chart. The results are applicable for improving the effectiveness of line balancing problems in the electronics industry.

MODAPTS 기반 자동차 조립공정 공수 산정에 관한 연구 (A Study on the Man-Hour Computation Based on MODAPTS in Automobile Assembly Line)

  • 이창호
    • 대한안전경영과학회지
    • /
    • 제23권1호
    • /
    • pp.65-70
    • /
    • 2021
  • Domestic as well as global automobile manufacturers are making greater efforts in cost reduction to strengthen the competitiveness. In this study, we developed a program to effectively manage standard time of automobile assembly line, and confirm based on A-automobile factory data. For the purpose, we develop the system which is possible to manage standard time as well as calculate man-hour for automobile assembly line.

EXPERIMENTAL SIMULATION OF A DIRECT VESSEL INJECTION LINE BREAK OF THE APR1400 WITH THE ATLAS

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Kang, Kyoung-Ho;Choi, Nan-Hyun;Kim, Dae-Hun;Park, Choon-Kyung;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.655-676
    • /
    • 2009
  • The first-ever integral effect test for simulating a guillotine break of a DVI (Direct Vessel Injection) line of the APR1400 was carried out with the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) from the same prototypic pressure and temperature conditions as those of the APR1400. The major thermal hydraulic behaviors during a DVI line break accident were identified and investigated experimentally. A method for estimating the break flow based on a balance between the change in RCS inventory and the injection flow is proposed to overcome a direct break low measurement deficiency. A post-test calculation was performed with a best-estimate safety analysis code MARS 3.1 to examine its prediction capability and to identify any code deficiencies for the thermal hydraulic phenomena occurring during the DVI line break accidents. On the whole, the prediction of the MARS code shows a good agreement with the measured data. However, the code predicted a higher core level than did the data just before a loop seal clearing occurs, leading to no increase in the peak cladding temperature. The code also produced a more rapid decrease in the downcomer water level than was predicted by the data. These observable disagreements are thought to be caused by uncertainties in predicting countercurrent flow or condensation phenomena in a downcomer region. The present integral effect test data will be used to support the present conservative safety analysis methodology and to develop a new best-estimate safety analysis methodology for DVI line break accidents of the APR1400.