• Title/Summary/Keyword: Safety Guideline

Search Result 927, Processing Time 0.027 seconds

A Study on the Affordance Factors for Enhancing Safety Behavior in Safety Education App (안전교육 앱에서 안전행동 증진을 위한 어포던스 요인에 관한 연구)

  • Baek, Hyeon-Gi;Ha, Tai-Hyun
    • Journal of Digital Contents Society
    • /
    • v.17 no.6
    • /
    • pp.489-497
    • /
    • 2016
  • This study focused on the focus group interview based on the questionnaire. Prior to the interview, we used questionnaires from the previous researchers in order to select the questionnaires and interviews of the focus group. In order to measure the possibility, which is the expression characteristic of the safety education app, the items related to cognitive, sensual, physical, and safety behaviors were used as constituent factors. And the safety education app to analyze was selected 'Water Go GO!' App developed by the National Emergency Management Agency. The results of this study are as follows: First, the learner should help to participate in learning continuously in order to make meaningful learning activities in safety education app learning environment. Second, learners must interact with mobile devices in their apps to facilitate learning while reducing the number of factors that can interfere with learners' learning. This study is meaningful in that it can utilize this design principle as a guideline for enhancing safety behaviors.

Classification of Food Safety Crises and Standard Setting for Crisis Level in Food Industry (식품산업체가 겪는 위기의 분류와 위기 수준 판단)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.133-145
    • /
    • 2015
  • Objectives: Food safety has become one of the major public-concerning issues in Korea. In order to set guidelines to create manuals for the response to a food safety crisis by food industry, this paper classified food safety crises and suggested techniques to determine crisis level. Methods: This study clarified common terminologies and definitions including in food safety crises. It reviewed various food safety crises and described characteristics, types, and states of crises. Results: The results of this study suggested that a food safety crisis implied a situation in which hazards/risk spreading in the food supply chain was widely described, causing strong public concern followed by a socioeconomic impact, and therefore, requiring the implementation of a prompt and full response regarding the situation. In terms of seeking response plans, food safety crises might be classified according to the penalties resulting from violations of laws and regulations, causative substances, stages of the food supply chain, and first contact point for incidents. The crisis level for a food safety crisis could be classified according to its severity parameters. The guideline matrix was divided into four major stages: Blue/guarded, Yellow/elevated, Orange/high, and Red/severe. This study also suggested several methods for determining the crisis level, such as the simple judgement method, scoring methods using a check-list and a weighted check-list. Conclusion: The severity of related parameters might be of great importance in understanding a crisis and determining response options/challenges for crisis levels.

Subacute Inhalation Toxicity of Cyclohexanone in B6C3F1 Mice

  • Lee, Yong-Hoon;Chung, Yong Hyun;Kim, Hyeon-Yeong;Shin, Seo Ho;Lee, Sang Bae
    • Toxicological Research
    • /
    • v.34 no.1
    • /
    • pp.49-53
    • /
    • 2018
  • Cyclohexanone ($C_6H_{10}O$, CAS No. 108-94-1) is a colorless oily liquid obtained through the oxidation of cyclohexane or dehydrogenation of phenol. It is used in the manufacture of adhesives, sealant chemicals, agricultural chemicals, paint and coating additives, solvent, electrical and electronic products, paints and coatings, photographic supplies, film, photochemicals, and as an intermediate in nylon production. Owing to the lack of information on repeated inhalation toxicity of cyclohexaone, in this study, we aimed to characterize the subacute inhalation toxicity. B6C3F1 mice were exposed to 0, 50, 150, and 250 ppm of cyclohexanone for 6 hr/day, 5 days/week for 4 weeks via whole-body inhalation in accordance with the OECD Test Guideline 412 (subacute inhalation toxicity: 28-day study). Mortality, clinical signs, body weights, food consumption, hematology, serum biochemistry, organ weights, as well as gross and histopathological findings were evaluated between the control and exposure groups. No mortality or remarkable clinical signs were observed during the study. No adverse effects on body weight, food consumption, hematology, serum biochemistry, and organ weights, gross or histopathological lesions were observed in any male or female mice in any of the exposure groups, although some statistically significant changes were observed in organ weights. We concluded that no observable adverse effect level (NOAEL) is above 250 ppm in mice exposed to cyclohexanone for 6 hr/day for 5 days/week.

Safety Assessment of Foods Produced Using Recombinant DNA Techniques

  • Toyoda, Masatake
    • Toxicological Research
    • /
    • v.17
    • /
    • pp.167-171
    • /
    • 2001
  • The introduction of genetically modified crops has raised concerns regarding safety issues over the insertion of foreign genes into plant genomes using recombinant DNA technology. Since 1991 in Japan, 29 foods and 6 food additives have been evaluated, based on the "Guideline for Safety Assessment", before these foods were marketed. The MHW, however, decided that safety assessment of such foods and food additives should be legally imposed. because soon such foods and food additives are expected to circulate globally and a new system for assessing safety of such foods and food additives at a pre-market stage is necessary, in order to avoid the distribution of any genetically modified foods that have had no safety assessment. The MHW published relevant announcements to amend existing regulations on 1 May 2000. "Standards for safety assessment of seed plant" is established based on a concept of substantial equivalence, and applicable to the products which are regarded as equivalent to the existing products used as foods and food additives. The characterization of the food products entails consideration of the molecular characterization. phenotypic and compositional characteristics, key nutrients and toxicants, and toxicity and allergenicity of the introduced proteins, and if there are indications of unintended effects of the modification, whether further safety testing (animal studies etc.) is needed should be considered. Safety and wholesomeness studies with whole foods should be care fully designed in order to avoid nutritional imbalances causing artifacts and uninterpretable results as was the case of Dr. Pusztaiis report. A case study of genetically modified soybeans (glyphosate-tolerant soybeans) on the immune system of rats and mice is shown. Chemical compositions were also compared with those of the non-GM soybeans. The studies failed to detect any differences in immuno-toxic activity.muno-toxic activity.

  • PDF

A Study on the Risk Factors at the Broadcasting Production Site (방송 제작 특성에 기반한 유해위험요인 분석)

  • Nam, Yun Kyung;Jin, Sangeun;Lee, Jong-Bin;Kim, Kyungwoo;Na, Minoh
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.67-75
    • /
    • 2020
  • Due to various industrial accident that occur to the staff in the broadcasting production sites, the issue of safety at the broadcast production site is becoming a social issue. Nevertheless, not many researches have been carried out on the actual conditions of the staff's production environment and its safety issues. Therefore, the purpose of this study was to prepare a countermeasure based on engineering knowledge by analyzing working environment to improve the poor working environment of staff. First, this study analyzed statistical data of industrial accidents over the past five years to find out the current status of disasters at broadcasting production sites. As a result, the intensity of the accident was not weak in that the loss days was more than one month in 85% of accident. In addition, the type of accident was high in the fall/trip accidents. Second, this study visited 10 broadcasting production sites for risk assessment. By analyzing the characteristics of the working environment and 104 questionnaires, we predicted the types of accidents that can occur in the broadcasting production site. As a result, accident types such as fall, collision, and trip were relatively high, similar to the characteristics of construction site. Third, it was possible to quantify the scale of the risk in the broadcasting production, and as a result, the quantity of temporary structure and accident risk were proportional. In other words, this study analyzes broadcasting work environment and defines risk factors based on safety engineering knowledge. Finally, this study suggested a guideline to improve the safety of the broadcasting production site.

Determination of Ceftiofur Residues by Simple Solid Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry in Eel, Flatfish, and Shrimp

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Lee, Eunhye;Choi, Soo Yeon;Lee, Hee-Seok;Cho, Byung-Hoon;Lee, Kang-Bong;Jeong, Jiyoon
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The aim of this study was conducted to develop an analytical method to determine the concentration of ceftiofur residue in eel, flatfish, and shrimp. For derivatization and extraction, the sample was hydrolyzed with dithioerythritol to produce desfuroylceftiofur, which was then derivatized by iodoacetamide to obtain desfuroylceftiofur acetamide. For purification, the process of solid phase extraction (Oasis HLB) was used. The target analytes were confirmed and quantified in $C_{18}$ column using liquid chromatography-tandem mass spectrometry with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as the mobile phase. The linearity of the standard calibration curve was confirmed by a correlation coefficient, $r^2>0.99$. The limit of quantification for ceftiofur was 0.002 mg/kg; the accuracy (expressed as the average recoveries) was 80.6-105%; the precision (expressed as the coefficient of variation) was below 6.3% at 0.015, 0.03, and 0.06 mg/kg. The validated method demonstrated high accuracy and acceptable sensitivity to meet the Codex guideline requirements. The developed method was tested using market samples. As a results, ceftiofur was detected in one sample. Therefore, it can be applied to the analysis of ceftiofur residues in fishery products.

Development of a User Experience Evaluation Methodology for Smart Safety Living Lab (스마트안전 리빙랩 환경에서의 사용자경험 평가를 위한 방법론 개발)

  • Choi, Jae-Rim;Ryu, Do-Hyeon;Kim, Kwang-Jae;Yun, Jung-Min;Kim, Min-Sun
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.2
    • /
    • pp.127-143
    • /
    • 2021
  • Purpose: Smart Safety Living Lab is a Living Lab facility, constructed and operated by KITECH in Korea, to support the user experience(UX) evaluation, planning and certification of smart safety products and services. The purpose of this study is to develop a UX evaluation methodology that accommodates the characteristics of the Living Lab and smart safety products and services for a systematic and efficient UX evaluation in the Smart Safety Living Lab. Methods: A generic model of UX evaluation was first derived based on a review of related literature. Then, the generic model is revised to accommodate the characteristics of the Smart Safety Living Lab and smart safety products and services, resulting in the UX Evaluation Methodology for Smart Safety Living Lab (SSLL-UXEM). Results: The developed SSLL-UXEM consists of a structured process for UX evaluation, a guideline for conducting each step of the process, and a set of forms for recording the major evaluation results in each step. Conclusion: SSLL-UXEM can help to enhance the efficiency of the UX evaluation process and the consistency of the UX evaluation results. SSLL-UXEM is also expected to serve as a basis for UX evaluation in various living lab environments in the future.

Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis (AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구)

  • Lee, Jeong Han;Kim, Yong Gon;Lee, Jae Won;Kim, Jong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

A Study on the Temporary Storage Facility for Mitigating the Leakage Accident (누출 사고 완화를 위한 임시 저장 시설에 관한 연구)

  • Song, Hyeon Oh;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.1-5
    • /
    • 2020
  • The leakage accident from a storage tank in an oil refinery plant occurred in April 2014 and the total loss is KRW 18 billion. This accident has prompted many companies to develop their own mitigation system to minimize the loss of the leakage accident. The aim of this study is to design the temporary storage facility system for dealing with leakage accidents. The basic concept of this system is that the leakage fluid of a hazardous material flows into a temporary storage tank and this is transferred to a spare tank by a pump as avoiding the overflow of a temporary storage tank. In order to design this system, the leakage velocity and quantity according to time series should be evaluated. In addition, a proper pump capacity should be determined to avoid repeating the pump switching on and off frequently. In this study, the benzene tank is selected to verify the efficacy of this system. This study can play a critical role to provide a guideline for designing a new system.

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.