• 제목/요약/키워드: Safety Function

검색결과 2,789건 처리시간 0.028초

원자력발전소 안전필수시스템 고장허용능력에 대한 자가진단기능 저하 영향 분석 (The Effect of the Fault Tolerant Capability due to Degradation of the Self-diagnostics Function in the Safety Critical System for Nuclear Power Plants)

  • 허섭;황인구;이동영;최헌호;김양모;이상정
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1456-1463
    • /
    • 2010
  • The safety critical systems in nuclear power plants should be designed to have a high level of fault tolerant capability because those systems are used for protection or mitigation of the postulated accidents of nuclear reactor. Due to increasing of the system complexity of the digital based system in nuclear fields, the reliability of the digital based systems without an auto-test or a self-diagnostic feature is generally lower than those of analog system. To overcome this problem, additional redundant architectures in each redundant channel and self-diagnostic features are commonly integrated into the digital safety systems. The self diagnostic function is a key factor for increasing fault tolerant capabilities in the digital based safety system. This paper presents an availability and safety evaluation model to analyze the effect to the system's fault tolerant capabilities depending on self-diagnostic features when the loss or erroneous behaviors of self-diagnostic function are expected to occur. The analysis result of the proposed model on the several modules of a safety platform shows that the improvement effect on unavailability of each module has generally become smaller than the result of usage of conventional models and the unavailability itself has changed significantly depending on the characteristics of failures or errors of self-diagnostic function.

Work Hours and Cognitive Function: The Multi-Ethnic Study of Atherosclerosis

  • Charles, Luenda E.;Fekedulegn, Desta;Burchfiel, Cecil M.;Fujishiro, Kaori;Hazzouri, Adina Zeki Al;Fitzpatrick, Annette L.;Rapp, Stephen R.
    • Safety and Health at Work
    • /
    • 제11권2호
    • /
    • pp.178-186
    • /
    • 2020
  • Background: Cognitive impairment is a public health burden. Our objective was to investigate associations between work hours and cognitive function. Methods: Multi-Ethnic Study of Atherosclerosis (MESA) participants (n = 2,497; 50.7% men; age range 44-84 years) reported hours per week worked in all jobs in Exams 1 (2000-2002), 2 (2002-2004), 3 (2004-2005), and 5 (2010-2011). Cognitive function was assessed (Exam 5) using the Cognitive Abilities Screening Instrument (version 2), a measure of global cognitive functioning; the Digit Symbol Coding, a measure of processing speed; and the Digit Span test, a measure of attention and working memory. We used a prospective approach and linear regression to assess associations for every 10 hours of work. Results: Among all participants, associations of hours worked with cognitive function of any type were not statistically significant. In occupation-stratified analyses (interaction p = 0.051), longer work hours were associated with poorer global cognitive function among Sales/Office and blue-collar workers, after adjustment for age, sex, physical activity, body mass index, race/ethnicity, educational level, annual income, history of heart attack, diabetes, apolipoprotein E-epsilon 4 allele (ApoE4) status, birth-place, number of years in the United States, language spoken at MESA Exam 1, and work hours at Exam 5 (β = -0.55, 95% CI = -0.99, -0.09) and (β = -0.80, -1.51, -0.09), respectively. In occupation-stratified analyses (interaction p = 0.040), we also observed an inverse association with processing speed among blue-collar workers (adjusted β = -0.80, -1.52, -0.07). Sex, race/ethnicity, and ApoE4 did not significantly modify associations between work hours and cognitive function. Conclusion: Weak inverse associations were observed between work hours and cognitive function among Sales/Office and blue-collar workers.

이중연료엔진의 연료가스공급시스템에 대한 안전무결도 기반 안전계장시스템 설계 (SIS Design for Fuel Gas Supply System of Dual Fuel Engine based on Safety Integrity Level(SIL))

  • 강낙원;박재홍;정정호;나성
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.447-460
    • /
    • 2012
  • In this study, the shutdown system of the fuel gas supply system is designed based on the Safety Integrity Level of IEC 61508 and IEC 61511. First of all, the individual risk($10^{-4}$/year) and the risk matrix which are the risk acceptance criteria are set up for the qualitative risk assessment such as the HAZOP study. The natural gas leakage at the gas supply pipe is identified as the highest risk among the hazards identified through the HAZOP study and as a safety instrumented function the shutdown function for leakage was defined. SIL 2 and PFD($2.5{\cdot}10^{-3}$) for the shutdown function are determined by the layer of protection analysis(LOPA). The shutdown system(SIS) carrying out the shutdown function(SIF) is verified and designed according to qualitative and quantitative requirements of IEC 61508 and IEC 61511. As a result of SIL verification and SIS conceptual design, the shutdown system is composed of two gas detectors voted 1oo2, one programmable logic solver, and two shutdown valve voted 1oo2.

식이섬유의 주요기능 (Nutritional Role of Dietary Fiber-Recent Knowledge on Dietary fiber)

  • Tsuji, Keisuke
    • 한국식품위생안전성학회지
    • /
    • 제7권4호
    • /
    • pp.173-176
    • /
    • 1992
  • Non-absorbable substances in foods, for instance dietary fiber had been previously known as a non-nutritive part of foods. Recently , such a category has been gradually changed to as one of nutrients, As a main reason, dietary fibers includes many poly-or oligo-saccharides, which as resistant to alimentary hydrolyzing enzyme, However, parts of them are fermented by intestinal micro-organism to produce short chain fatty acids and so on. They are absorbed and utilized by human being. Now, it may be naturally accepted that dietary fiber is a kind of nutrients. Dietary fiber exerts many useful functions on body. They are classified into three large function , physicochemical function, physiological function and biological function. The last function of dietary fiber will be presented in the symphosium. Dietary fiber has several kinds of nutritional properties. One is energy source. Short chain fatty acids(SCFA) are oxidized and produced energy in body. Dietary fiber has not high energy, but not zero kilocalories. Another one is to be a constitutional component of higher animals' tissue. Last but most important one is physiological functions of dietary fiber.

  • PDF

옻나무 (Rhus verniciflua Stokes) 추출물의 알코올대사 효소활성에 미치는 여향 (Effect of Rhus verniciflua Stokes Extract on the Alcohol-Metabolizing Enzyme Activities)

  • 유귀재;김소영;최아름;손민희;김동청;채희정
    • KSBB Journal
    • /
    • 제24권1호
    • /
    • pp.101-105
    • /
    • 2009
  • Alcohol oxidation activities and optimization of extraction conditions of Rrhus verniciflua Stokes (RVS) extract were evaluated for the development of a functional biomaterial for improving liver function. When alcohol oxidation activities of RVS was analyzed, the Rrhus verniciflua Stokes bark (RVSB) were higher than the Rrhus verniciflua Stokes heartwood (RVSH). Alcohol oxidation activity value of RVSB increased in a concentration-dependent manner. In the comparative analysis between Hovenia dulcis Thunb (HOT) and Alnus japonica Steud (AJS) which was reported as a alcohol oxidation material, alcohol oxidation activity is much higher than the others. The experimental conditions were optimized for alcohol oxidation-active components production from RVSB. The extraction conditions such as temperature, time, pH and particle size were performed. It was recommended to extract the alcohol oxidation-active components from RVSB by hot water (pH 7.0) at $85^{\circ}C$ for 8 hours.

대학기숙사 교육기능공간의 매개변수를 통한 인과분석 (Causal Analysis of Education Function Space Parameters of University Dormitory)

  • 박행자;박성진;노영란
    • 한국주거학회논문집
    • /
    • 제21권4호
    • /
    • pp.23-31
    • /
    • 2010
  • This study aims to examine the educational function space of university dormitories at local universities with corridor centered structure in Honam area regions based on direct and indirect parameters on the whole satisfaction of users in residential environment factors and personal characteristics. First, according to relations among parameters, educational and cultural activities of four major activities within the dormitory had indirect influences on social activities, eating and sleeping activities had no direct influence on other activities. And social activity had direct influence on the general satisfaction as an important parameter and educational and cultural activities had indirect influence on the whole satisfaction through social activities. Detailed results show that, in the first educational activities directly affecting the lighting and air conditioning facilities (0.22), safety (0.326), Territoriality (0.327), the space density (-0.167), directions (-0.166) and yeohyang having personal characteristics and the safety of the second cultural activities (0.183), Territoriality (0.361), Aesthetics (-0.13) and the personal characteristics Sex (-0.179), the direct effect, third, and erosion has a direct impact on activity The flexibility of the space factor (-0.128) and Territoriality (0.38) and the personal characteristics grade (0.172), respectively. Fourth in social activities directly affecting the pathfinding (-0.104), and parameter, education (0.388) and cultural activities (0.445), and some of the factors affecting the indirect lighting and air conditioning facilities, safety, and Territoriality, the space density, directions, grade, they could influence through educational activities to be analyzed. That is, territoriality in educational function space is the important factor that users react very sensitively in educational, eating and sleeping activities and educational function space must secure area and division considering personal and public use as the space accommodating activity which is lacking in unit residential space. Accordingly, the safety of educational function space in university dormitory is considered as the fundamental safety matter on the fire prevention, hygiene and cleanness for users in the satisfaction of educational and cultural activities.

비선형 회귀분석을 이용한 Generic 데이터 기반의 누출빈도함수 추정 (Estimation of Leak Frequency Function by Application of Non-linear Regression Analysis to Generic Data)

  • 윤익근;단승규;정호진;홍성경
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.15-21
    • /
    • 2020
  • Quantitative risk assessment (QRA) is used as a legal or voluntary safety management tool for the hazardous material industry and the utilization of the method is gradually increasing. Therefore, a leak frequency analysis based on reliable generic data is a critical element in the evolution of QRA and safety technologies. The aim of this paper is to derive the leak frequency function that can be applied more flexibly in QRA based on OGP report with high reliability and global utilization. For the purpose, we first reviewed the data on the 16 equipments included in the OGP report and selected the predictors. And then we found good equations to fit the OGP data using non-linear regression analysis. The various expectation functions were applied to search for suitable parameter to serve as a meaningful reference in the future. The results of this analysis show that the best fitting parameter is found in the form of DNV function and connection function in natural logarithm. In conclusion, the average percentage error between the fitted and the original value is very small as 3 %, so the derived prediction function can be applicable in the quantitative frequency analysis. This study is to contribute to expand the applicability of QRA and advance safety engineering as providing the generic equations for practical leak frequency analysis.

효율적인 전과정 평가를 위한 환경 기능 전개 시스템 개발 (Development of Environment Function deployment for Efficient Life Cycle Assessment)

  • 양광모;김순진;강경식
    • 대한안전경영과학회지
    • /
    • 제8권1호
    • /
    • pp.113-130
    • /
    • 2006
  • As environmental damage increase by a highly developed material civilization of today, many companies take a growing immensely interest in the influence of environment for beginning a new paradigm year by year. The previous assessments dose not run the gamut of industry but is confined within a certain facility or an area. Industrial processes and operations can not be accomplished independently but are connected with each others through suppliers and customer, and these ideas are fundamental notions of Life Cycle Assessment(LCA). This paper will introduce Life Cycle Assessment(LCA) in environment which is rising, and would like to build environmental management system using approach of Quality Function Deployment(QFD) and Safety Function Deployment(SFD) belonging to the assessment method.

Determination of THRs - A Practical Approach for Manufacturers According to EN50129

  • Weber, Ulrich
    • 한국철도학회논문집
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2013
  • The paper will outline how hazard identification and risk evaluation can effectively be performed to obtain Tolerable Hazard Rates (THR). As a target group manufacturers are addressed, who face the situation, that for a generic application THRs are needed for compliance with EN 50129 [1]. Focusing on functional hazards this paper shows a possible hazard log and the relevant analysis methods. The terms safety barrier and barrier function will be introduced and used instead of the term "safety function". As functional hazards and barrier functions depend on each other, emphasis will be put on a comprehensive and detailed definition of barrier functions and the usage of function lists. By using detailed and complete hazard and barrier function definitions THRs can be obtained while at the same time the approach becomes clear how the hazard rates (HR) will be established.

필수성능 분석을 통한 효율적인 의료기기 기능안전 접근 방안 (Efficient Approaches of Functional Safety for Medical Equipment using Essential Performance Analysis)

  • 김기영;유기훈;박호준;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.27-32
    • /
    • 2015
  • Functional safety is part of the overall safety relating to the equipment under control (EUC) and the EUC control system that depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems. Since the complexity of the medical equipment is increased, manufactures have to obtain functional safety as well as basic safety. This study proposes a perspective for applying functional safety to medical equipment. The research is carried out with respect to overall safety life-cycle of functional safety and essential performance of the medical equipment. The relationship between functional safety and essential performance is identified centered on the safety function. The essential performance using E/E/PE systems is defined as a safety function of functional safety. This approach is applied to a ultrasound imaging system as a case study.