• 제목/요약/키워드: Safety Assessment Factor

검색결과 526건 처리시간 0.025초

Integrity Evaluation System of CANDU Reactor Pressure Tube

  • Kim, Young-Jin;Kwak, Sang-Log;Lee, Joon-Seong;Park, Youn-Won
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.947-957
    • /
    • 2003
  • The pressure tube is a major component of the CANDU reactor, which supports nuclear fuel bundle. In order to complete the integrity evaluation of pressure tube, expert knowledge, iterative calculation procedures and a lot of input data are required. More over, results of integrity assessment may be different according to the evaluation method. For this reason, an integrity evaluation system, which provides efficient way of evaluation with the help of attached database, was developed. The present system was built on the basis of 3D FEM results, ASME Sec. XI, and Fitness For Service Guidelines for CANDU pressure tubes issued by the AECL (Atomic Energy Canada Limited). The present system also covers the delayed hydride cracking and the blister evaluation, which are the characteristics of pressure tube integrity evaluation. In order to verify the present system, several case studies have been performed and the results were compared with those from AECL. A good agreement was observed between those two results.

육체운동에 의해 유발되는 화학물질에 대한 반응성의 변화 (Alteration in Response to Chemicals Induced by Physical Exercise)

  • 김영철
    • Toxicological Research
    • /
    • 제18권3호
    • /
    • pp.215-226
    • /
    • 2002
  • Acute or repeated physical exercise affects a large number of physiological parameters including hemodynamics, respiration, pH, temperature, gastrointestinal function and biotransformation, which determine the pharmacokinetics of drugs and chemicals. The rate and the amount of a chemical reaching the active site are altered by physical exercise, which results in significant changes in pharmacolosical/toxicological activity of the chemical. This aspect of physical exercise has vast implication in therapeutics and in safety evaluation, particularly for chemicals that have a low margin of safety. However there appears to be a wide inter- and intraindividual variation in the effects of physical exercise depend-ing on the duration, intensity and type of exercise, and also on the properties of each chemical. It is suggested that more studies need to be done to determine which factor(s) plays a major role in the disposition of chemicals in human/animals performing physical exercise. Certain chemicals induce severe toxicity due to metabolic conversion to reactive intermediate metabolites. it is suggested that repeated exercise may enhance the free radical scavenging system by increasing the activity of antioxidant enzymes. This area of research remain to be explored to elucidate the interaction of exercise and chemical on the antioxidant system.

수입 농산물의 식품 안전성 관리 현황 (Food Safety Assurance of Imported Agricultural Products)

  • 오창환
    • 농촌의학ㆍ지역보건
    • /
    • 제31권1호
    • /
    • pp.63-79
    • /
    • 2006
  • Korea's self-sufficient food ratio on a quantity basis remained a low 27.6 per cent for cereals in year 2004. Even the public auction of imported rice from the United States kicked off a couple of days ago to allow foreign rice to be sold directly to consumers on the Korea market for the first time. Therefore the safety of imported food must be a great concern of Korean consumers. All imported agricultural products are supposed to be quarantined for controlling the insect and inspected for the potent risk like residual pesticides, aflatoxin, sulfur dioxide and genetically modified. agricultural products. The 12 percent of agricultural products contained the insects detected by National Plant Quarantine was fumigated with methyl bromide or aluminum phosphide and entered the custom. The most large portion of violated agricultural products (24 cases in 2004) inspected by Korea Food and Drug Administration was dried herbal medicinal foods contaminated by sulfur dioxide which must be treated when they were dried in China. The second factor made the imported agricultural products to be criminals (19 cases in 2004) was residual pesticides. Genetically modified agricultural products like soybean and corn are under control by labelling in Korea. Genetically modified soybean and corn have been used for oil expression mostly. It is the time to set up realistic risk assessment system for our consumer with the pouring imported agricultural products.

  • PDF

보안 위험분석을 위한 안정성 평가 시스템 설계 및 구현 (Design and implementation on Safety assesment system for security threat analyzing)

  • 조경식
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권2호
    • /
    • pp.333-339
    • /
    • 2007
  • 대부분의 조직에서 정보시스템의 의존도가 높아짐에 따라 정보시스템 보안 사고에 대한 위험이 증가하고 있다. 본 논문에서는 정보보호관리체계와 위험분석방법을 적용하여 보안 위험분석을 위한 안정성 평가시스템을 설계 및 구현하였다. 또한, 위험평가 시 동일한 가중치를 적용한 평가와 조직의 특성에 따라 보안요소의 가중치를 가변적으로 적용한 평가를 할 수 있도록 하였으며 각 조직이 자체적으로 보안 점검을 할 수 있도록 설계함으로서 관리 측면에서 취약점을 쉽게 찾을 수 있도록 지원하며. 안정성 확보를 위하여 수행해야 할 권고를 제시한다.

  • PDF

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

소형풍력발전기의 설계하중 평가 연구 (An Assessment Study for Design Load of a Small Wind Turbine)

  • 현승건;김건훈;허종철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.48-53
    • /
    • 2011
  • In this study, it is to verify the applicability for a simplified model(IEC61400-2, Design Require-ments for Small Wind Turbines, 2006-03) is the international standard is used to the structural design. In the design process of a wind turbine, the safety of a designed wind turbine is one of the most important factors. The simplified model can be used to determine the design load for small wind turbines. So, this paper has been re-evaluated a small wind turbine design loads that produced already. As a result, the material characteristic value(Rchar) of Blade, Rotor shaft and the tower are $90E6[N/m^2]$, $441E6[N/m^2]$ and $94E6[N/m^2]$. Therefore, the value of the applied safety factor to each part of the survival probability of 95% are satisfied.

  • PDF

환경친화적 물류활동의 실태에 관한 연구 (A Study on the conditions of the Environment-Conscious Logistics Activity)

  • 박석하;김현수
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.229-240
    • /
    • 2008
  • With the effectuation of Kyoto Protocol, one of the important movement throughout the world is reducing the emission of greenhouse gas which is the main reason of making global warming. The actual factor of greenhouse gas is CO2, and in year of 2002 20% of total CO2 emission was produced only through transportation throughout the South Korea. In the contrary, the recycling of municipal wastes in South Korea was 44.0% in 2002, but it will be targeted upto 53.5% in 2011. All of these show environment-conscious logistics should be implemented together throughout the each stage of distribution with the development of product and service. This study applied survey research for the activities affecting to the emission of CO2 and packaging wastes produced from transportation and packaging stages in logistics area. For this, survey questionary was constructed with five specific areas - strategy, transportation & distribution, custody, packaging, and information. Based on the 148 returned survey questionaries, this study analyzed 52 categories and finally suggests necessary modal shift, collaboration & co-operation in logistics, LCA(life-cycle assessment), and other promoting policies for the environment-conscious logistics in effective way.

국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션 (Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant)

  • 강대일;김길유;장승철;유성연
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

CFD APPLICATION TO THE REGULATORY ASSESSMENT OF FAC-CAUSED CANDU FEEDER PIPE WALL THINNING ISSUE

  • Kang, Dong-Gu;Jo, Jong-Chull
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.37-48
    • /
    • 2008
  • Flow fields inside feeder pipes have been simulated numerically using a CFD (computational fluid dynamics) code to calculate the shear stress distribution, which is the most important factor in predicting the local regions of feeder pipes highly susceptible to FAC (flow-accelerated corrosion)-induced wall thinning. The CFD approach, with schemes used in this study, to simulate the flow situations inside the CANDU feeder pipes has been verified as it showed a good agreement between the investigation results for the failed feedwater pipe at Surry unit 2 plant in the U.S. and the CFD calculation. Sensitivity studies of the three geometrical parameters, such as angle of the first and second bends, length of the first span between the grayloc hub and the first bend, and length of the second span between the first and the second bends have been performed. CFD analysis reveals that the local regions of feeder pipes of Wolsung unit 1 in Korea, on which wall thickness measurements have been performed so far, are not coincident with the worst regions predicted by the present CFD analysis located in the connection region of straight and bend pipe near the inlet part of the bend intrados. Finally, based on the results of the present CFD analysis, a guide to the selection of the weakest local positions where the measurement of wall thickness should be performed with higher priority has been provided.

저장 온도와 저장 기간에 따른 즉석 우럭(Sebastes schlegeli) 미역국 동결건조 블록의 품질 특성 변화 및 유통기한 추정 (Effects of Different Storing Temperature and Period on Quality and Shelf-life of Freeze Dried-block Type of Convenience Food for Rockfish Sebastes schlegeli Seaweed Soup)

  • 정성목;이상민
    • 한국수산과학회지
    • /
    • 제55권4호
    • /
    • pp.425-430
    • /
    • 2022
  • This study was designed to verify the shelf-life of a freeze dried-block type of convenience food for rockfish Sebastes schlegeli seaweed soup product stored at different storing temperatures (25, 35, and 45℃) for 5 months. The polyunsaturated:saturated fatty acid ratio of the product stored at 25℃ was higher than that of products stored at 35℃ and 45℃ for 5 months. The colorimetric assessment indicated a noticeable decrease in the brightness of product color after 5months of storage at 35℃ and 45℃. Increased storage temperature and time negatively affected the product color. The products stored at 35℃ and/or 45℃ for more than 3 months tended to be more yellowish-red in color than those stored at 25℃ for shorter periods. No disease-causing microorganisms, including Escherichia coli and Staphylococcus aureus, posing health hazards to the human, were detected on food safety evaluation, regardless of storage conditions. Based on food visual shelf life simulator the shelf life of the rockfish seaweed soup was estimated approximately 22 months, considering the data from yellowness the safety factor of 0.7.