• Title/Summary/Keyword: SV30

Search Result 189, Processing Time 0.031 seconds

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

Comparative evaluation of radiation exposure in radiation-related workers (방사선 작업종사자의 피폭선량 비교 평가)

  • Baek, Seong-Min;Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.195-200
    • /
    • 2011
  • The purpose of this study is to investigate the dose of radiation exposure to radiation-related workers in a hospital setting, thus increasing awareness of the health risk to the radiation-related workers. The result of the analysis showed the average dose of radiation exposure to radiation-related workers in hospital K was $0.75{\pm}0.26mSv$ in 2008, $0.67{\pm}0.30mSv$ in 2009, and $0.92{\pm}0.33mSv$ in 2010. The average dose of radiation exposure in hospital P was $0.43{\pm}0.13mSv$ in 2008, $0.43{\pm}0.20mSv$ in 2009, and $0.33{\pm}0.85mSv$ in 2010. The average dose of radiation exposure in hospital K by age group was 13.39mSv for age 20 to 29, 8.37mSv for age 30 to 39, 1.19mSv for age 40 to 49, 0.28mSv for age 50 to 59, and 0.32mSv for age 60 to 69 The average dose of radiation exposure in hospital P by age group was 0.33mSv for age 20 to 29, 1.41mSv for age 30 to 39, 0.83mSv for age 40 to 49, 1.66mSv for age 50 to 59, and 1.12mSv for age 60 to 69. Moreover, the average radiation exposure to radiation-related workers over 3 year period by gender group in hospital K was $2.92{\pm}1.03mSv$ for male group and $0.94{\pm}0.93mSv$ for female group. The average radiation exposure over 3 year period by gender group in hospital P was $0.66{\pm}0.18mSv$ for male group and $1.80{\pm}0.60mSv$ for female group. Persons working in diagnostic radiology department received mean of $1.65{\pm}1.54mSv/year$, mean $1.17{\pm}0.82mSv/year$ in radiation oncology, mean $1.79{\pm}1.42mSv/year$ at nuclear medicine department and mean $0.99{\pm}0.51mSv/year$ at other departments. Radiation exposure was higher than that of other departments(p<0.05). Doctors and technologists received higher radiation exposure (mean $1.75{\pm}1.17mSv/year$, $1.60{\pm}1.39mSv/year$ each) than other workers(p<0.05). Measurement and evaluation of radiation exposure in radiation-related workers should be widely conducted accurately and consistently in the radiation-related occupational setting so that people in these occupational settings are more aware of the risk from radiation exposure, and thus give more attention and caution to decrease radiation exposure. It would be essential to minimize accumulated radiation dose in the radiation-related occupational setting in order to maintain and improve the health of radiation-related workers.

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.

Change of the Scattered Dose by Field Size in X-ray Radiography (X선 촬영에서 조사야 크기에 따른 산란선량의 변화)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • The purpose of this study is to investigate the scattered dose of X-ray at a distance of 30cm from the area to be examined when X-ray field is the most optimized and maximized when X-ray is performed on hand, skull and abdomen. As a result of scattered dose of X-ray on hand, skull and abdomen, first, when X-ray field was the most optimized upon adult X-ray examination, it was $0.08{\mu}Sv$, $4.39{\mu}Sv$ and $5.56{\mu}Sv$, respectively. When x-ray field was maximized, it was $0.58{\mu}Sv$, $33.47{\mu}Sv$ and $35.93{\mu}Sv$, respectively. Second, when X-ray field was the most optimized upon pediatric X-ray examination, it was $0.40{\mu}Sv$, $14.51{\mu}Sv$ and $18.86{\mu}Sv$, respectively. When x-ray field was maximized, it was $2.78{\mu}Sv$, $107.40{\mu}Sv$ and $117.52{\mu}Sv$, respectively(P<0.001). As a result, when the size of X-ray field was decreased down to be necessary and optimal upon X-ray examination, emission of scattered X-ray around specimen is reduced approximately 6-7 times as much as that when it was maximized.

Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine (이동형 구내 방사선촬영기로 촬영한 치근단 방사선사진의 흡수선량 및 유효선량 평가)

  • Cho, Jeong-Yeon;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.149-156
    • /
    • 2007
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. Materials and Methods: 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. Results: On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Conclusion: Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines.

  • PDF

Inhibitory Effects of Toxic Materials on Activation of Microorganisms in Coke Plant Wastewater (코크스폐수에 함유된 $S^{-2}$$SCN^-$이 미생물 활성에 미치는 영향)

  • Kim, Sang-Sik;Lee, Kisay
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.423-427
    • /
    • 2013
  • This research was carried out to identify the characteristics of the wastewater from coke oven gas (COG) purification process of the coke plant, and derive optimal operating conditions for the treatment of wastewater. The coke plant wastewater contains highly concentrated $S^{-2}$ and $SCN^-$ that are harmful to microorganisms, and their concentrations were 6.8~11.2 mg/L and 190~320 mg/L, respectively. When the $S^{-2}$ ion concentration was lower than 10 mg/L, $SV_{30}$ of active sludge was 280~ 340 mL and the sludge sedimentation velocity was very fast. But, when the $S^{-2}$ ion concentration was higher than 15 mg/L, $SV_{30}$ of the active sludge was 560~680 mL and the sludge sedimentation velocity was very slow. Also when the $SCN^-$ ion concentration was lower than 300 mg/L, $SV_{30}$ of the active sludge was 245~320 mL and the sludge sedimentation velocity was very fast. But, when the $SCN^-$ ion concentration was higher than 400 mg/L, $SV_{30}$ of the active sludge was 470~ 567 mL and the sludge sedimentation velocity was slow. To treat the wastewater generated by COG purification process of the coke plant effectively and to maintain microorganism activities in good conditions, the ion concentration of $S^{-2}$ and $SCN^-$ should be lower than 15 mg/L and 400 mg/L, respectively.

Investigations of the External Dose Rate (${\mu}Sv/h$), the Residual Activity (mCi) and the Excretion Rate (%) of Thyroid Cancer Patients Hospitalized for 3700 MBq (100 mCi) $^{131}I$ Radioiodine Treatment ($^{131}I$ 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(${\mu}Sv/h$), 잔류량(mCi), 배설률(%) 측정)

  • Bae, Gi-Han;Kim, Hwa-Joong;Choi, Jae-Jin;Lee, Won-Guk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2009
  • Purpose: As Korean nuclear law doesn't have any clear guideline about the dose and the external dose rate(uSv/h) requiring hospitalization in radioactive iodine treated patients, the patients are discharged when they meet the guideline of IAEA Basic Safety Standards(BSS). We measured external dose rate(${\mu}Sv/h$) of inpatient underwent 3700MBq (100 mCi) $^{131}I$ radioiodine treatment and considering external dose rate(${\mu}Sv/h$), residual activity(mCi) and excretion rate(%) we found the time for RA to be lowered from 3700MBq (100 mCi) to 1110 MBq (30 mCi) to give reference to set a guideline for discharge. Materials and Methods: Forty-two patients underwent thyroidectomy and scheduled for radioiodine treatment, who received 3700MBq (100 mCi) of $^{131}I$ orally and had no renal disease were examined. After 1, 2, 4, 8, and 20, 24, 40 hours iodine uptake and before/after the urination, the external dose rate(${\mu}Sv/h$) measured using FH40G-L(Thermo Fisher Scientific Inc., MA) at a distance and a height of 1 m for 20 sec on the average. Results and Conclusions: At 20 hours, the external dose rate was decreased to $49{\pm}13\;{\mu}Sv$/h, namely, 78% of administrated radioactivity was excreted and 814 MBq (30 mCi) was residual, and it met the accepted limit for discharge of (IAEA, BSS) under 1110 MBq (30 mCi) (1 m at 66 uSv/h).

  • PDF

Occupational Radiation Exposure in Korea: 2002 (2002년 국내 방사선 작업종사자의 직업군별 피폭선량)

  • Jeong, Je-Ho;Kwon, Jeong-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • Dose distribution of Korean radiation workers classified by occupational categories was analyzed. Statistics of the occupational radiation exposure(ORE) in 2002 of the radiation workers in diagnostic and dental radiology were obtained from the Korea Food and Drug Agency(KFDA) who maintains the database for individual radiation dose records. Corresponding statistics for the rest of radiation workers were obtained by processing the individual annual doses provided by the Korea Radioisotope Association(KRIA) after deletion of individual information. The ORE distribution was classified in term of 28 occupational categories, annual individual dose levels, age groups and gender of 52733 radiation workers as of the year of 2002. The total collective dose was 66.4 man-Sv and resulting average individual ORE was 1.26 mSv. Around 80% of the workers were exposed to minimal doses less than 1.2 mSv. However, it appeared that the recorded doses exceeded 20 mSv for 43 workers in the industrial radiography and for 147 workers in the field of radiology. Particularly, recorded doses of 23 workers in radiology exceeded the annual dose limits of 50 mSv, which is extraordinary when the working environment is considered. It is uncertain whether those doses are real or caused by careless placing of dosimeters in the imaging rooms while the X-ray units are in operation. No one in the workforce of 16 operating nuclear power plant units was exposed over 20 mSv in 2002. Number of workers was the largest in their 30's of age and the mean individual dose was the highest in their 20's. Women were around 20% of the radiation workers and their average dose was around one half of that of man workers.

An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station (방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석)

  • Han, Jae-Jin;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

Delivery of Hypoxia Inducible Heme Oxygenase-1 Gene Using Dexamethasone Conjugated Polyethylenimine for Protection of Cardiomyocytes under Hypoxia

  • Kim, Hyun-Jung;Kim, Hyun-Ah;Choi, Joon-Sig;Lee, Min-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.897-901
    • /
    • 2009
  • Heme oxygenase-1 (HO-1) is an anti-inflammatory and anti-apoptotic protein and has been applied to various gene therapy researches. However, constitutive expression of HO-1 may induce deleterious side effects. In this research, hypoxia inducible HO-1 expression plasmid, pEpo-SV-HO-1, was constructed with the erythropoietin (epo) enhancer and simian virus 40 (SV40) promoter to avoid these unwanted side effects. Dexamethasone conjugated polyethylenimine (PEI-Dexa) was used as a gene carrier. It was previously reported that dexamethasone protected cardiomyocytes from apoptosis under hypoxia. In this research, PEI-Dexa reduced the caspase-3 level in hypoxic H9C2 cardiomyocytes as a derivative of dexamethasone, suggesting that PEI-Dexa is an anti-apoptotic reagent as well as a gene carrier. pEpo-SV-HO-1 was transfected to H9C2 cardiomyocytes using PEI-Dexa and the cells were incubated under normoxia or hypoxia. HO-1 expression was induced in the pEpo-SV-HO-1 transfected cells under hypoxia. In addition, cell viability under hypoxia was higher in the pEpo-SV-HO-1 transfected cells than the pEpo-SV-Luc transfected cells. Also, caspase-3 level was reduced in the pEpo-SV-HO-1 transfected cells under hypoxia. In addition to the anti-apoptotic effect of PEI-Dexa, hypoxia inducible HO-1 expression by pEpo-SVHO- 1 may be helpful to protect cardiomyocytes under hypoxia. Therefore, pEpo-SV-HO-1/PEI-Dexa complex may be useful for ischemic heart disease gene therapy.