• Title/Summary/Keyword: SUV

Search Result 337, Processing Time 0.025 seconds

The Imaging Features of Desmoid Tumors: the Usefulness of Diffusion Weighted Imaging to Differentiate between Desmoid and Malignant Soft Tissue Tumors

  • Lee, Seung Baek;Oh, Soon Nam;Choi, Moon Hyung;Rha, Sung Eun;Jung, Seung Eun;Byun, Jae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.162-170
    • /
    • 2017
  • Purpose: To evaluate the imaging findings of desmoid tumors using various imaging modalities and to evaluate whether diffusion-weighted imaging (DWI) can help differentiate between desmoid and malignant tumors. Materials and Methods: The study included 27 patients with pathologically confirmed desmoid tumors. Two radiologists reviewed 23 computed tomography (CT), 12 magnetic resonance imaging (MRI) and 8 positron emission tomography-computed tomography (PET-CT) scans of desmoid tumors and recorded data regarding the shape, multiplicity, size, location, degree of enhancement, and presence or absence of calcification or hemorrhage. The signal intensity of masses on T1- and T2-weighted imaging and the presence or absence of whirling or band-like low signal intensity on T2-weighted imaging were recorded. The apparent diffusion coefficient (ADC) values of the desmoid tumors in nine patients with DWIs were compared with the ADC values of 32 malignant tumors. The maximum standardized uptake value ($SUV_{max}$) on PET-CT images was measured in 8 patients who underwent a PET-CT. Results: The mean size of the 27 tumors was 6.77 cm (range, 2.5-26 cm) and four tumors exhibited multiplicity. The desmoid tumors were classified by shape as either mass forming (n = 18), infiltrative (n = 4), or combined (n = 5). The location of the tumors was either intra-abdominal (n = 15), within the abdominal wall (n = 8) or extra-abdominal (n = 4). Among the 27 tumors, 21 showed moderate to marked enhancement and 22 showed homogeneous enhancement. Two tumors showed calcifications and one displayed hemorrhage. Eleven of the 12 MR T2-weighted images showed whirling or band-like low signal intensity areas in the mass. The mean ADC value of the desmoid tumors ($1493{\times}10^{-6}mm^2/s$) was significantly higher than the mean of the malignant soft tissue tumors ($873{\times}10^{-6}mm^2/s$, P < 0.001). On the PET-CT images, all tumors exhibited an intermediate $SUV_{max}$ (mean, 3.7; range, 2.3-4.5). Conclusion: Desmoids tumors showed homogenous, moderate to marked enhancement on CT and MRI scans and a characteristic whirling or band-like pattern on T2-weighted images. DWI can be useful for the differentiation of desmoid tumors from malignant soft tissue tumors.

Sensibility Evaluation for Car Navigation System based on Vehicle-type Preference (선호 차종별 자동차 네비게이션 시스템의 감성평가)

  • Park Sung Joon;Kim Sung Hoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.9 no.3
    • /
    • pp.71-79
    • /
    • 2004
  • Owing to the rapid increase of the number of automobiles, the traffic is being heavily crippled as time goes by. To provide drivers with better safety and convenience, a variety of CNSs(Car Navigation System) are being installed more and more specially for the vehicles which are produced in recent days. As the CNS has gained the public popularity, it has been playing a role as a component of the multimedia system in a vehicle in addition to providing the capability of route guidance service. It is, therefore, now recognized as an important unit of the vehicle interior system. As the situation has been changed as formerly described, it is necessary that not only the functions but also the usability and exterior features are to be designed to suit customers' tastes. This paper is an attempt to find out what the major sensibility factors which customers want as far as a CNS is concerned are. Because these factors can differ from a vehicle type to another that customers prefer, the analysis is based on the vehicle preference. It is proved that MDS(Multi Dimensional Scaling) is an effective method to analyze the sensibility factors for the different types of vehicles. The result shows that for the people who prefer the sedan-type vehicles, luxuriousness, harmoniousness, and texture are major factors. For people who like sports car, faminism, salience, and dynamics are major factors. For people who prefer SUV's(Sports Utility Vehicle) or MPV's(Multi Purpose Vehicle), solidity, dynamics, and convenience are important.

  • PDF

Effect of Glucose Level on Brain FDG-PET Images (FDG를 이용한 Brain PET에서 Glucose Level이 영상에 미치는 영향)

  • Kim, In-Yeong;Lee, Yong-ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.275-280
    • /
    • 2017
  • In addition to tumors, normal tissues, such as the brain and myocardium can intake $^{18}F$-FDG, and the amount of $^{18}F$-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting $^{18}F$-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0.84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using $^{18}F$-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients.

A Study on Proposition of The Assisting Mechanism for Wheelchair Transfer for Car (차량용 휠체어 이송을 위한 보조메커니즘의 제안에 관한 연구)

  • Lim, K.;Kim, Y.S.;Yang, S.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.251-258
    • /
    • 2014
  • A wheelchair is a typical mobility aid for the physically disabled or the old and the weak, and is the most commonly used rehabilitation aid. In general, most of users of manual wheelchair have difficulty though vocational rehabilitation and independent living is possible. The reason is that long-distance movement is always accompanied with wheelchair transfer problem because a wheelchair is used as direct means of transport. Hence, the wheelchair transfer problem should be first solved in order that a wheelchair user can independently live. Therefore, this study examined and analyzed the domestic and overseas launched products and patented technologies of wheelchair transfer system for vehicle, and proposed a wheelchair transfer mechanism of a new system for vehicle. This study proposed a wheelchair transfer mechanism for vehicle in order to remove the disadvantage of wheelchair transfer system for vehicle to support the conventional wheelchair user's movement, and in order to conform with the structure of domestic welfare vehicle for the disabled. Because a difference between storage space installed in the roof of vehicle and storage space for leisure, which is generally utilized, gets to disappear by applying this proposed mechanism, popularity among users can be increased. And storage space that has become smaller like this will be capable of decreasing the disadvantage of air resistance in traveling. Besides, because of getting to conform with the structure of welfare vehicle, restrictions on the application range will disappear from small sedan to SUV. Therefore, users can have more choices.

  • PDF

A Study of Diabetic Control for Diabetic Patient in $^{18}F$-FDG PET ($^{18}F$-FDG PET 검사를 위한 당뇨 환자의 혈당 조절에 관한 연구)

  • Cha, Min-Kyeong;Nam, Ki-Pyo;Lee, Young-Hee;Choi, Jae-Min;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Purpose: $^{18}F$-FDG PET is to evaluate the tumor using glucose metabolism. Blood Glucose Level (BGL) is important factor that affects on a result of examination. But it often appears the distort result on diabetic patient due to a failure of BGL control. The aim of this study is to make a effective guideline for diabetic patient prescribed $^{18}F$-FDG PET and improve accuracy and reliability of examination. Materials and methods: A subject of study is 69 diabetic patients and divided them into 3 groups; 1) BGL is less than 120 mg/dl & performed PET, 2) BGL is over than 120 mg/dl & performed PET, 3) BGL is over than 120 mg/dl & not performed PET. And we investigated the type of diabetic medications and the time of dosage, whether they have meal or not. And we analyzed SUV of liver and mediastinum to recognize the effect of BGL on PET images. Results: As a methods to diabetic control, Amalyl showed high percentage of 27.5% in oral medication and Humulin R showed 14.5% in insulin. Their peak time was 2-3 hrs, 2-4 hrs and duration time was 24 hrs, 5-7 hrs. The number of that had a breakfast was 16, 7 mens (43.8%) couldn't perform PET as over 120 mg/dl and 5 mens (31.3%) performed PET as less than 120 mg/dl after they took a medication. When we set the SUV of normal for 1.5-2.0, 1.0-1.5 on liver and mediastinum, the percentage out of the range was 31.8%, 52.9%, 62.5% in 120-139 mg/dl, 140-159 mg/dl, 160-200 mg/dl respectively. Conclusions: We completed standardized guideline for diabetic patients. As a result of this study, improved customer satisfaction and increased economic benefits. It is expect to be a effective model in other PET centers.

  • PDF

Physical Properties and Skin Penetration of Niosome Formulations Containing Minoxidil and Diaminopyrimidine Oxide (미녹시딜과 다이아미노피리미딘옥사이드 성분을 함유하는 니오좀 제형의 물성 및 피부투과)

  • Bo Kyung Kim;Won Hyung Kim;Kyung-Sup Yoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.2
    • /
    • pp.127-139
    • /
    • 2023
  • In this study, minoxidil, which is well known as a pharmaceutical raw material, and diaminopyrimidine oxide (DAO), which is a cosmetic raw material, were used as active ingredients to evaluate the physical properties of niosomes and compare the skin penetrations of artificial skin. To prepare niosomes of the size of nanoparticles, a high pressure homogenization method was used, and physical properties were evaluated with a zetasizer. The particle size of the noisome including the active ingredient was measured to be 99 to 123 nm according to HLB, and the zeta potential was measured in the range of -60 to -81 mV. Through DSC (differential scanning colorimetry), it was confirmed that minoxidil, a crystalline component, was uniformly dissolved in an amorphous state in niosomes. In order to confirm and compare skin penetration, it was measured by the in vitro Franz diffusion cell method, and the niosome formulation showed 3.4 times higher penetration for minoxidil and 11.1 times higher penetration for DAO than the control gel formulation. In addition, when comparing the skin penetration of minoxidil niosome and DAO niosome, a similar trend was shown, and the penetration amount of DAO was relatively high. The shapes of the niosome formulations with different HLB values were observed using Cryo-TEM, and it was confirmed that vesicles were formed in all of them and that they were intermediate between SUV (small unilamella vesicle) and LUV (large unilamella vesicle). Through this study, minoxidil, an effective drug for hair loss, and DAO, a cosmetic raw material, can be effectively delivered to the skin by encapsulating them in a noisome formulation.

Optimization of Flushing through Correlation Analysis between the Number of Flushing and Residual Activity in PET/CT (PET/CT에서 최적의 플러싱횟수를 위한 잔류방사능과의 상관분석)

  • Woo-Yeong Choi;Yeong-Sik Jee;Chang-Yong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.701-707
    • /
    • 2023
  • In PET/CT, the injection volume of 18F-FDG directly affects the SUV(standard uptake value), which can affect the reading results. Therefore, it is important to inject the correct dose value of 18F-FDG. In this study, we performed the correlation between the residual radioactivity remaining in the syringe and catheter insertion device according to the number of flushing during 18F-FDG injection. CRC-25R dose calibrator, catheter insertion devices, 3 cc syringes and 50 cc physiological saline were used in this study, and the results were statistically analyzed. As a result, the total residual radioactivity of the syringe and catheter insertion device remained the highest at 5.84% after two flushing, and the least remained at 1.49% after five flushing. The correlation analysis results showed that the number of flushing had a negative correlation with the residual radioactivity of the syringe at -0.436 and the catheter insertion device at -0.300. As a result of one-way distributed analysis of the average according to the number of flushing, the syringe showed a significant decrease at 4 times, and the catheter insertion device showed a significant decrease at 5 times. However, considering that an average of 0.8% remains in the case of catheter insertion devices, four time flushing seems to be the most appropriate.

Role of Chemical Exchange Saturation Transfer and Magnetization Transfer MRI in Detecting Metabolic and Structural Changes of Renal Fibrosis in an Animal Model at 3T

  • Anqin Li;Chuou Xu;Ping Liang;Yao Hu;Yaqi Shen;Daoyu Hu;Zhen Li;Ihab R. Kamel
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.588-597
    • /
    • 2020
  • Objective: To investigate the value of combined chemical exchange saturation transfer (CEST) and conventional magnetization transfer imaging (MT) in detecting metabolic and structural changes of renal fibrosis in rats with unilateral ureteral obstruction (UUO) at 3T MRI. Materials and Methods: Thirty-five Sprague-Dawley rats underwent UUO surgery (n = 25) or sham surgery (n = 10). The obstructed and contralateral kidneys were evaluated on days 1, 3, 5, and 7 after surgery. After CEST and MT examinations, 18F-labeled fluoro-2-deoxyglucose positron emission tomography was performed to quantify glucose metabolism. Fibrosis was measured by histology and western blots. Correlations were compared between asymmetrical magnetization transfer ratio at 1.2 ppm (MTRasym(1.2ppm)) derived from CEST and maximum standard uptake value (SUVmax) and between magnetization transfer ratio (MTR) derived from MT and alpha-smooth muscle actin (α-SMA). Results: On days 3 and 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of contralateral kidneys (p < 0.05). On day 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of sham-operated kidneys (p < 0.05). The MTRasym(1.2ppm) of UUO renal medulla was fairly negatively correlated with SUVmax (r = -0.350, p = 0.021), whereas MTR of UUO renal medulla was strongly negatively correlated with α-SMA (r = -0.744, p < 0.001). Conclusion: CEST and MT could provide metabolic and structural information for comprehensive assessment of renal fibrosis in UUO rats in 3T MRI and may aid in clinical monitoring of renal fibrosis in patients with chronic kidney disease.

Brain Metabolic Network Redistribution in Patients with White Matter Hyperintensities on MRI Analyzed with an Individualized Index Derived from 18F-FDG-PET/MRI

  • Jie Ma;Xu-Yun Hua;Mou-Xiong Zheng;Jia-Jia Wu;Bei-Bei Huo;Xiang-Xin Xing;Xin Gao;Han Zhang;Jian-Guang Xu
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.986-997
    • /
    • 2022
  • Objective: Whether metabolic redistribution occurs in patients with white matter hyperintensities (WMHs) on magnetic resonance imaging (MRI) is unknown. This study aimed 1) to propose a measure of the brain metabolic network for an individual patient and preliminarily apply it to identify impaired metabolic networks in patients with WMHs, and 2) to explore the clinical and imaging features of metabolic redistribution in patients with WMHs. Materials and Methods: This study included 50 patients with WMHs and 70 healthy controls (HCs) who underwent 18F-fluorodeoxyglucose-positron emission tomography/MRI. Various global property parameters according to graph theory and an individual parameter of brain metabolic network called "individual contribution index" were obtained. Parameter values were compared between the WMH and HC groups. The performance of the parameters in discriminating between the two groups was assessed using the area under the receiver operating characteristic curve (AUC). The correlation between the individual contribution index and Fazekas score was assessed, and the interaction between age and individual contribution index was determined. A generalized linear model was fitted with the individual contribution index as the dependent variable and the mean standardized uptake value (SUVmean) of nodes in the whole-brain network or seven classic functional networks as independent variables to determine their association. Results: The means ± standard deviations of the individual contribution index were (0.697 ± 10.9) × 10-3 and (0.0967 ± 0.0545) × 10-3 in the WMH and HC groups, respectively (p < 0.001). The AUC of the individual contribution index was 0.864 (95% confidence interval, 0.785-0.943). A positive correlation was identified between the individual contribution index and the Fazekas scores in patients with WMHs (r = 0.57, p < 0.001). Age and individual contribution index demonstrated a significant interaction effect on the Fazekas score. A significant direct association was observed between the individual contribution index and the SUVmean of the limbic network (p < 0.001). Conclusion: The individual contribution index may demonstrate the redistribution of the brain metabolic network in patients with WMHs.

A Novel Melanin-Targeted 18F-PFPN Positron Emission Tomography Imaging for Diagnosing Ocular and Orbital Melanoma

  • Yiyan Wang;Xinghua Wang;Jie Zhang;Xiao Zhang;Yang Cheng;Fagang Jiang
    • Korean Journal of Radiology
    • /
    • v.25 no.8
    • /
    • pp.742-748
    • /
    • 2024
  • Objective: 18F-N-(2-(Diethylamino)ethyl)-5-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy) picolinamide (18F-PFPN) is a novel positron emission tomography (PET) probe designed to specifically targets melanin. This study aimed to evaluate the diagnostic feasibility of 18F-PFPN in patients with ocular or orbital melanoma. Materials and Methods: Three patients with pathologically confirmed ocular or orbital melanoma (one male, two females; age 41-59 years) were retrospectively reviewed. Each patient underwent comprehensive 18F-PFPN and 18F-fluorodeoxyglucose (18F-FDG) PET scans. The maximum standardized uptake value (SUVmax) of the lesion and the interference caused by background tissue were compared between 18F-PFPN and 18F-FDG PET imaging. In addition, the effect of intrinsic pigments in the uvea and retina on the interpretation of the results was examined. The contralateral non-tumorous eye of each patient served as a control. Results: All primary tumors (3/3) were detected using 18F-PFPN PET, while only two primary tumors were detected using 18F-FDG PET. Within each lesion, the SUVmax of 18F-PFPN was 2.6 to 8.3 times higher than that of 18F-FDG. Regarding the quality of PET imaging, the physiological uptake of 18F-FDG PET in the brain and periocular tissues limited the imaging of tumors. However, 18F-PFPN PET minimized this interference. Notably, intrinsic pigments in the uvea and retina did not cause abnormal concentrations of 18F-PFPN, as no anomalous uptake of 18F-PFPN was detected in the healthy contralateral eyes. Conclusion: Compared to 18F-FDG, 18F-PFPN demonstrated higher detection rates for ocular and orbital melanomas with minimal interference from surrounding tissues. This suggests that 18F-PFPN could be a promising clinical diagnostic tool for distinguishing malignant melanoma from benign pigmentation in ocular and orbital melanomas.