• 제목/요약/키워드: SUPER Concrete

검색결과 291건 처리시간 0.026초

레일 매립궤도의 특성과 노면철도에 적용 가능성에 관한 연구 (Embedded Rail Track on the LRT(Tram))

  • 이기승;김성칠;백진기;고동춘
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.394-399
    • /
    • 2005
  • Embedded rail track can be described as a track structure that is completely covered within pavement. Rail supported continually on a concrete slab or concrete plinth. There are many kinds of types such as non-resilient track and resilient track, super resilient embedded track (floating slab). Embedded rail track is generally the standard for light rail transit routes because this track has many advantages such as reducing noise, maintenance cost and weight of track. In this paper, decision of track profile is restricted by the optimum levels of the flangeway and the gap between the rail head and the pavement surface of depressing tread zone. By result of this study, embedded rail track can reduce corrosion of rail, internal stress and rail deflection.

  • PDF

강섬유 특성이 숏크리트 품질에 미치는 영향 (Quality Evaluation of shotcrete due to Properties of Steel Fiber)

  • 류종현;김동원;전현규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.673-676
    • /
    • 2006
  • Steel FibreReinforced Shotcrete(SFRS) is one of the main tunnel support along with the rock bolt during the excavation and after the completion of the tunnel. In the standard qualification of the SFRS defined by Korea Highway Corporation, 28 day core specimen has to meet the compressive strength of 19.6 MPa and over 90 % fibre contents. Furthermore, for the 28 days brick shaped specimen made by shooting, flexural strength should be over 4.4 MPa and flexural toughness ratio which can be calculated from flexural toughness factor has to meet more than 68% of flexural strength. In shotcrete, accelerating agent is added for the rapid strength development. Silicate and aluminate type agents are known to develop shotcrete strength rapidly, however, has such problem to degrade the middle and long term strength. Hence, using poly carboxylic super plasticizer, it was aimed to enhance the quality of the shotcrete with the lower water-cement ratio and the same level of workability. The present paper shows the part of the field test result and its analysis.

  • PDF

CGS를 잔골재로 활용하는 FA치환 콘크리트의 응결시간 추정시 개량형 듀로미터 사용 가능성 분석 (Utilization of Improved Durometer when Estimating Setting Time of FA Replacement Concrete Using CGS for Fine Aggregate)

  • 이혁주;신용섭;서항구;한인덕;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.81-82
    • /
    • 2019
  • In this study, the Proctor penetration resistance test value and the hardness value of the improved Durometer were compared and analyzed for the change in the FA replacement rate of the concrete using CGS fine aggregate. The results are summarized as follows. It is. 1) The Proctor penetration resistance test value and the hardness value of the improved Durometer showed a high correlation in the form of a curve. 2) About surface finish Super-resolution with the improved Durometer is considered to be useful when using about 50 HD and about 80 HD in the end to determine the surface finishing work time.

  • PDF

등가재령을 활용한 초고성능 콘크리트의 압축강도 예측식 제안 (A Proposal for Predicting the Compressive Strength of Ultra-high Performance Concrete Using Equivalent Age)

  • 백성진;박재웅;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.149-150
    • /
    • 2023
  • This study proposes the most suitable strength prediction model equation for UHPC by calculating the apparent activation energy of UHPC according to the curing temperature and deriving the integrated temperature and compressive strength prediction equation. The results are summarized as follows. The apparent activation energy was calculated using the Arrhenius function, which was calculated as 21.09 KJ/mol. A model equation suitable for UHPC was calculated, and when the Flowman model equation was used, it was confirmed that it was suitable for the properties of UHPC using a condensation promoting super plasticizing agent.

  • PDF

기후변화의 온도와 습도 양생조건에 따른 콘크리트 재료특성의 성능중심평가 (Performance Based Evaluation of Concrete Material Properties from Climate Change Effect on Temperature and Humidity Curing Conditions)

  • 김태균;신재호;신동우;심현보;김장호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.114-122
    • /
    • 2014
  • 현재 전 세계적으로 석탄, 석유 등 화석연료의 사용으로 지구 온난화가 진행되고 있다. 이러한 원인으로 폭염, 폭설, 폭우 및 슈퍼태풍 등과 같은 이상기후, 극한기후 현상이 지속적으로 증가 하고 있다. 또한 심각한 자연재해로 콘크리트 구조물 및 사회기반시설의 심각한 손상과 붕괴가 발생한다. 이러한 문제들을 해결하기 위해서는 기후변화에 적합한 기준 및 시공 기술 등이 필요한 실정이므로 본 연구에서는 다양한 온도와 습도 양생조건이 콘크리트 배합에 미치는 영향을 검토해 보았다. 다양한 온도와 습도 조건에서 양생된 콘크리트의 압축강도와 할렬인장강도 실험을 수행하였다. 또한 성능중심평가 (performance based evaluation (PBE))방법을 사용하여 다양한 양생조건에서 경화된 콘크리트 강도의 만족도확률을 평가하였다. 또한 콘크리트의 성능중심평가로부터 얻는 결과 값을 바탕으로 기후변화가 배합에 미치는 영향을 고려하여 배합설계에 적용할 수 있다.

전기로 산화 슬래그 잔골재 치환율 변화가 석회암 기반 초고강도 모르타르의 기초적 특성에 미치는 영향 (Influence of Various Replacement Ratio of Electric Arc Furnace Fine Aggregate on Fundamental Properties of Limestone Based High Strength Mortar)

  • 문병룡;송원루;이제현;김민상;한인덕;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2016
  • As the demand for super tall buildings is currently increased in domestic and foreign countries, some kinds of ultra-high strength concretes are being developed actively. Since the cross section of concrete becomes smaller thanks to such kinds of ultra-high strength concretes, the concrete structures can be much bigger, more gigantic and much ultra-high. And as another benefit which is generated thanks to the enhancement of the durability performance, the maintenance expenses are also saved. However, since low W/B ultra-high concrete has a high possibility that many cracks can occur in the initial period due to the self-shrinkage caused by the self-desiccation as one of the blending characteristics, the problem becomes bigger by influencing the safety of a structure. Therefore, in this study, it is intended to analyze the effects of substituting some limestone-based ultra-high strength mortar with electric arc furnace oxidizing slag fine aggregates on the self-shrinkage of mortar.

  • PDF

프리믹스 시멘트의 물리적 특성에 미치는 결합재조합 및 실리카퓸 종류의 영향 (Effect of the Various Combinations of the Binders and the Silica Fume Types to the Physical Properties of the Pre-Mix Cement)

  • 김성일;김기훈;배장춘;이해일;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.37-40
    • /
    • 2007
  • This study investigates the effect of the pre-mix cement to the physical properties of the concrete according to the various combinations of the binders and the silica fume types. The results are summarized as following. For the properties of the fresh, the fluidity in the case that OPC+cilica fume-blast-furnace slag is appropriate compared to OPC+cilica fume+fly ash. Expecially, it is favorable when pre-mix is used. The fluidity time of the A, B depending on silica fume types is favorable, but it is decreased on C. The air content depending on silica fume types is low when the fly ash is used. Specially, the air content in the case that pre-mix is used is low caused by the dispersion of the silica fume. For the properties of the hardened concrete, the compressive and flexible strength when the blast-furnace slag is pre-mixed are high, and they exceed OPC. The strength depending on the silica fume types is high on B, and the strength of the others is similar.

  • PDF

지하식 LNG 저장탱크 구조물의 온도균열 제어에 관한 연구 (A Study on the Thermal Crack Control of the In-Ground LNG Storage Tank as Super Massive Structures)

  • 권영호
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.773-780
    • /
    • 2011
  • 이 연구는 초대형 매스 구조물인 지하식 LNG 저장탱크의 바닥슬래브 및 측벽에 타설되는 매스 콘크리트의 재료특성, 배합조건, 양생조건 및 콘크리트의 타설시기와 초기온도, 외기온 등을 고려한 온도응력 해석 결과를 기술하였다. 해석 결과를 토대로 유해한 균열의 발생 가능성을 예측하고, 이를 방지하기 위한 방안을 제시하였다. 이 연구에서는 콘크리트의 단열온도 상승시험을 통하여 수화열 관리에 유리하다고 평가된 2종류(벨라이트 시멘트+석회석 미분말)의 최적배합조건을 선정하였다. 온도응력 해석의 결과에 따르면, 바닥슬래브 2단을 제외한 대부분의 분할타설 블록에서 관통균열지수가 1.2이상을 만족하였다. 바닥슬래브 2단의 경우 균열방지 대책으로 선행냉각 방안을 제시하였으며, 콘크리트의 초기온도를 $25^{\circ}C$ 범위에서 관리할 경우에는 대부분의 타설블록에서 관통균열지수 1.2이상을 만족하는 것으로 나타났다. 또한, 바닥슬래브의 경우, 표면균열지수가 1.2이상이기 때문에 양생조건을 준수하면 표면균열을 제어할 수 있으며, 측벽의 경우에도 표면균열지수가 1.0이상을 만족하기 때문에 균열의 수 및 폭을 제어할 수 있는 것으로 나타났다.

개구부가 있는 벽식구조물의 3차원해석을 위한 슈퍼요소와 부분구조의 이용 (Use of Super Elements and Substructures for Three Dimensional Analysis of the Box System with Openings)

  • 이동근;김현수;남궁계홍
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.3-10
    • /
    • 2001
  • The box system that is composed only of reinforced concrete walls and slabs are adopted on many high-rise apartment buildings recently constructed in Korea. And the framed structure with shear wall core that can effectively resist horizontal forces is frequently adopted for the structural system for high-rise building structures. In these structures, a shear wall may have one or more openings for functional reasons. It is necessary to use subdivided finite elements for accurate analysis of the shear wall with openings. But it would take tremendous amount of computational time and memory if the entire building structure is subdivided into a finer mesh . An efficient analysis method that can be used regardless of the number, size and location of openings is proposed in this study, The analysis method uses super element, substructure, matrix condensation technique and fictitious beam technique. Three-dimensional analyses of the box system and the framed structure with shear wall core having various types of openings were performed to verify the efficiency of the proposed method. It was confirmed that the proposed method have outstanding accuracy with drastically reduced time and computer memory from the analyses of example structures.

  • PDF

The Structural Design of Tianjin Goldin Finance 117 Tower

  • Liu, Peng;Ho, Goman;Lee, Alexis;Yin, Chao;Lee, Kevin;Liu, Guang-lei;Huang, Xiao-yun
    • 국제초고층학회논문집
    • /
    • 제1권4호
    • /
    • pp.271-281
    • /
    • 2012
  • Tianjin Goldin Finance 117 tower has an architectural height of 597 m, total of 117 stories, and the coronation of having the highest structural roof of all the buildings under construction in China. Structural height-width ratio is approximately 9.5, exceeding the existing regulation code significantly. In order to satisfy earthquake and wind-resisting requirements, a structure consisting of a perimeter frame composed of mega composite columns, mega braces and transfer trusses and reinforced concrete core containing composite steel plate wall is adopted. Complemented by some of the new requirements from the latest Chinese building seismic design codes, design of the super high-rise building in high-intensity seismic area exhibits a number of new features and solutions to professional requirements in response spectrum selection, overall stiffness control, material and component type selection, seismic performance based design, mega-column design, anti-collapse and stability analysis as well as elastic-plastic time-history analysis. Furthermore, under the prerequisite of economic viability and a series of technical requirements prescribed by the expert review panel for high-rise buildings exceeding code limits, the design manages to overcome various structural challenges and realizes the intentions of the architect and the client.