• Title/Summary/Keyword: STL Data

Search Result 133, Processing Time 0.024 seconds

A Study on Virtual Machine Design Simulator (가상 기구설계 시뮬레이터에 관한 연구)

  • Yim, Hong-Jae;Ju, Jae-Hwan;Sung, Sang-Jun;Jang, Si-Youl;Lee, Kee-Sung;Shin, Dong-Hoon;Jeong, Jae-Il;Lim, Si-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1559-1563
    • /
    • 2007
  • This paper presents a virtual machine design simulation program. Kinematics of various mechanisms can be modeled with 3 dimensional geometry and actuators. CAD data for any machine component can be easily imported in STL format. Machine components are assembled with kinematic joints simply by drag and drop function in virtual graphic simulator. Interference and collision of any component with other components can be identified during the motion simulation. Graphic user interface program is developed using Microsoft Direct X code. A precision micro stage system is demonstrated with the proposed virtual machine design simulator.

  • PDF

Development of conversion software from 3D model data to G-code (3D 모델 데이터의 G-code 변환 소프트웨어 개발)

  • Joo, Woosung;Mo, Junseo;Kim, Sungsuk;Yang, Sun-Ok;Gil, Jun-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.430-432
    • /
    • 2016
  • 최근 3D 프린터의 활용 분야가 확대되면서 이와 관련된 다양한 연구가 활발하게 진행되고 있다. 본 연구에서는 3D 프린팅 될 3D 모델 데이터를 3D 프린터가 이해할 수 있는 G-code로 변환할 수 있는 소프트웨어를 개발하고자 한다. 일반적으로 STL 파일 형식으로 저장된 3D 모델은 특별한 규칙없이 저장된 여러 facet들로 구성되어 있다. 본 연구에서는 우선 이러한 facet들의 Z축 좌표 값을 기준으로 정렬을 수행한 후, 이를 순차적으로 G-code로 변환하는 소프트웨어를 개발하였다.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Making Human Phantom for X-ray Practice with 3D Printing (3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • General phantom for practical X-ray photography Practical phantom is an indispensable textbook for radiology, but it is difficult for existing commercially available phantom to be equipped with various kinds of phantom because it is an expensive import. Using 3D printing technology, I would like to make the general phantom for practical X-ray photography less expensive and easier. We would like to use a skeleton model that was produced based on CT image data using a 3D printer of FDM (Fused Deposition Modeling) method as a phantom for general X-ray imaging. 3D slicer 4.7.0 program is used to convert CT DICOM image data into STL file, convert it to G-code conversion process, output it to 3D printer, and create skeleton model. The phantom of the completed phantom was photographed by X - ray and CT, and compared with actual medical images and phantoms on the market, there was a detailed difference between actual medical images and bone density, but it could be utilized as a practical phantom. 3D phonemes that can be used for general X-ray practice can be manufactured at low cost by utilizing 3D printers which are low cost and distributed and free 3D slicer program for research. According to the future diversification and research of 3D printing technology, it will be possible to apply to various fields such as health education and medical service.

Development of Design Support Tool for Building 3D printing (건축물 3D 프린팅 설계지원도구 개발)

  • Lee, Dongyoun;Seo, Myoung-Bae;Ju, Ki-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.94-105
    • /
    • 2020
  • Recently, most studies of 3D printing in construction have focused on the development of 3D printers and materials suitable for construction 3D printers. In comparison, there has been little research on design support tools that enable representative BIM data of building modeling tools to be applied to 3D printing. In addition, existing 3D printing slicing programs are commercialized around manufacturing, showing that they are unsuitable for construction 3D printing. Therefore, this research aims to develop a design support tool for 3D printing for buildings. The developed design support tool was validated based on arbitrary BIM data. Verification showed that wall pattern generation was modeled accurately without errors, and a calculation of the construction period showed that the formula presented in this study was valid. Furthermore, the maximum length of the mesh split was set to 100mm to minimize errors when converting to STL files.

STUDY ON AUTOMATIC 3D WING SHAPE MODELING AND GRID GENERATION (3차원 날개 모델링 및 격자 생성 자동화에 대한 연구)

  • Ryu, G.Y.;Kim, B.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.125-129
    • /
    • 2009
  • In this paper automatic 3D wing shape modeling program is introduced. The program is developed in Visual Basic based on Net Framework 3.5 environment by using CATIA COM Library, and it is used together with CATIA system to model 3D wings with or without flaps. With this program users can easily construct wing models by specifying geometry parameters which are usually design variables with the aid of easy-to-use GUI environment, and specifying sectional airfoil data is done either by using analytic shape functions such as NACA series airfoils or by providing input files with point data describing the airfoil shape. When all the input parameters are provided, users can either work further with the model in the CATIA system which would be automatically started by the program or save the resultant model in the format of users choice. Unstructured grid generation program is also briefly described which can make grid generation task for a 3D wing easy and efficient one when used together with the wing modeling program by choosing STL format as the model's output format.

  • PDF

The Automatic Determination of the Optimal Build-Direction in Rapid Prototyping (고속적층조형법에서 최적 적층방향의 자동결정)

  • 채희창
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.150-155
    • /
    • 1997
  • Rapid Prototyping(RP) is the technique which is used to make prototypes or functional parts directly using the 3-D solid data. Before building the prototype, several processes such as transfering 3D data from CAD system(STL) determination of build-direction, adding support structure and slicing are required. Among the above processes. determination of build-direction is the target of this study. The build direction is determined by many factors according to the objective of the user, like part accuracy, number of support structure, build time, amount of trapped volume, etc, But it is not easy to determine the build-direction because there are many factors and some factors have dependent properties with one another. So, in this study the part accuracy, the number of support structures and build time are considered as the main factor to determine the optimal build-direction. To determine the optimal build-direction for increasing part accuracy, sum of projected area which caused stairstepping effect was considered. The less the projected area is the better part accuracy is About the optimal build-direction to minimize the amount of support structure, sum of projected area of facets that require support structures was considered. About the build time, we considered the minimum height of part we intended. About the build time, we considered the minimun height of part we intended to make.

  • PDF

Concurrent Engineering Approach to the Die Design of Metal Forming Process using Rapid Prototyping and Finite Element Analysis (쾌속 3차원 조형법과 유한요소해석을 연계한 소성가공 금형설계의 동시공학적 접근방법)

  • Part, K.;Yoon, J.W.;Cho, J.R.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.146-154
    • /
    • 1996
  • In this work, rapid prototyping and three-dimensional finite element analysis are simultaneously applied to the die design of metal forming processes. Rapid prototyping is a new prototyping technology which produces three-dimensional part models directly from CAD data and has been extensively applied to various manufacturing processes. There are many types of rapid prototyping systems due to their building principles and materials. In this work, Stereolithography Apparatus(SLA), which is the most widely used rapidprototyping system, is introduced to manufacture the die set. For general preparation of STL file, which is the standard input file of rapid prototyping system, mesh data which are used in describing the die surface in finite element analysis are translated so that rapid prototyping and finite element analysis are dffectively connected. A die set for spider forging and a clover punch for deep drawing section are manufactured effciently using SLA prototypes, and metal forming experiments are carried out using them. Comparing the result of experiments with that of analyses, the processes can be predicted and designed successfully.

  • PDF

Liquid-Liquid Equilibrium and Physical Properties of Aqueous Mixtures of Poly (Ethylene Glycol) 3000 with Tri-Potassium Citrate at Different pH: Experiment, Correlation and Thermodynamic Modeling

  • Ketabi, Mahnam;Pirdashti, Mohsen;Mobalegholeslam, Poorya
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.1
    • /
    • pp.12-23
    • /
    • 2019
  • The new experimental data of liquid-liquid equilibrium (LLE) of aqueous two-phase system (ATPS) consisting of poly(ethylene glycol) 3000 + tri-potassium citrate at different pH were presented. It was found that an increase in pH resulted in the expansion of the two-phase region. The TLL and STL increased with increasing the pH values. The Merchuk equation can be appropriately employed to correlate the binodal curves and also the tie-line compositions were adjusted to both the Othmer-Tobias and Bancroft equations. In order to calculate the compositions of the phase and the ends of the tie-lines, density and refractive indices as two physical properties were used. Finally, the extended UNIQUAC, UNIFAC, Virial-(Mobalegholeslam & Bakhshi) and modified UNIQUAC-FV were used to measure the phase equilibria at different pH. The results of the models suggested that it can be used quite well to correlate the LLE in an aqueous solution of polymer-salt.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.