• Title/Summary/Keyword: STEL concentration

Search Result 19, Processing Time 0.022 seconds

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

Effect of STEL-toluene on Metabolism of Benzene in Rats (단시간 허용농도의 toluene이 benzene대사에 미치는 영향)

  • Roh, Jae-Hoon;Shin, Dong-Chun;Park, Jung-Gyun;Moon, Young-Hahn;Chung, Ho-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.152-162
    • /
    • 1988
  • Benzene and toluene, which are widely used aromatic hydrocarbons in workplace, are recently proved to cause health hazards due to their toxic effects. This study investigated the influence of toluene on the urinary excretion of benzene metabolite by administering short term exposure limit(STEL) of these compounds(i.e., 13.8mg/kg of benzene and 108.8 mg/kg of toluene) intraperitoneally into Sprague-Dawley rats. After administration, urinary phenol concentration of rat was measured by gas chromatography for every three hours. Data were analyzed by non-parametric statistical methods using Kruskal-Wallis multi-sample test and Mann-Whitney U test. The following results were obtained : 1. Administration of STEL-benzene increased urinary phenol concentration in lats. 2. Urinary phenol concentration was increased logarithmically according to the dosage of benzene. 3. Excretion of phenol in urine was decreased when benzene and toluene were administered simultaneously compared with administering benzene alone. In summary, these results reveal that administration of STEL of toluene has antagonistic effect of urinary excretion of benzene metabolite in rats.

  • PDF

A Study on Worker-Exposure to Formaldehyde in Some Histological Laboratories of Hospitals (일부 종합병원 조직검사실에서의 포름알데히드 노출에 관한 연구)

  • Park, Jiyoung;Zong, Moonshik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.95-104
    • /
    • 1998
  • This Study was conducted at nine Histological Laboratories in the hospitals located in Seoul from August 20 to October 10, 1996. The main purpose of this study was to assess the TWA & STEL exposure to formaldehyde and to evaluate factors affecting formaldehyde concentration in Histological Laboratory. With evaluated factors, proper improvement strategy to minimize exposure was suggested. The results are summarized as follows ; 1. The TWA concentrations of the personal samples ranged from 0.02 to 3.86 ppm and that of one laboratory out of nine was exceeding 0.75 ppm, USA OSHA standard. The TWA concentrations of the area samples ranged from 0.08 ppm to 1.49 ppm and those of three laboratories out of nine were exceeding OSHA standard. 2. When measurement was conducted on the working tables. around Formaldehyde vessel, fixation container and storage cabinet, the geometric means of TWA concentrations were 0.62 ppm, 0.64 ppm. 0.58 ppm and 0.37 ppm respectively. 3. When overnight fixed specimens were examined, the STEL concentrations of personal samples ranged from 0.59 ppm to 5.01 ppm, those of three laboratories out of nine were exceeding 2 ppm, OSHA standard and the STEL concentrations of area samples ranged from 0.31 ppm to 3.08 ppm, those of four laboratories from nine were exceeding OSHA standard. 4. Factors affecting Formaldehyde exposure level were sanitation state of laboratory, volume of the room and opening state of fixation container & formaldehyde vessel(p<0.05).

  • PDF

A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers (테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구)

  • Chio, Ho Chun;Hong, Jwa Ryung;Lee, Gye Young;Kim, Doo Ho;Park, Chung Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

A Study on the Necessity in Establishment of STEL of Dimethylformamide (DMF) - on the focus of the exposure in synthetic leather factories - (디메틸포름아미드(DMF)에 대한 단시간 노출기준 설정의 필요성에 관한 연구 -합성피혁사업장 중심으로-)

  • Lee, Sun Woo;Kim, Tae Hyeung;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.80-90
    • /
    • 2008
  • This study was carried out to investigate the correlation of urinary NMF concentration in workers exposed to DMF and concentration of DMF in the workplace. Samples were collected in workers exposed to high dose solvent in the synthetic leather factory by using silicagel tubes for 5-15 minutes, and were analyzed by GC. Geometric mean concentrations of DMF in the workplaces were 4.67 ppm in normal operation and 63.95 ppm in high exposure operation. The concentration of case uppers and machine cleaning process were more than 100 ppm in short time. The correlation of urinary NMF in workers and DMF in workplace was statistically significant in normal operation and high exposure operation. Correlation coefficient are 0.215(p<0.05) and 0.263(p<0.05). The result implied that STEL of DMF should be established in normal operation processes as well as high exposure operation processes.

Study on the Short Term Exposure Level (STEL) of the Benzene for the Tank Lorry Truck Drivers during Loading Process

  • Park Doo Yong
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 2004
  • Some of the petroleum products contain benzene which is well known as a confirmed human carcinogen. For example, gasoline products contain benzene ranging up to several percents by weight. High exposures to the benzene and other organic solvents would be likely to occur during intermittent tasks and or processes rather than continuous jobs such as sampling, repair, inspection, and loading/unloading jobs. The work time for these jobs is various. However, most of work time is very short and the representative time interval is 15 minutes. Thus, it is preferable to do exposure assessment for 15 minute time weighted average which is known as a short time exposure level(STEL) by ACGIH rather than for 8-hours TWA. It is particularly significant to the exposure monitoring for benzene since it has been known that the exposure rate plays an important role to provoke the leukemia. Due to the large variations, a number of processes/tasks, the traditional sampling technique for organic solvents with the use of the charcoal and sampling pumps is not appropriate. Limited number of samples can be obtained due to the shortage of sampling pumps. Passive samplers can eliminate these limitations. However, low sampling rates resulted in collection of small amount of the target analysts in the passive samplers. This is originated the nature of passive samplers. Field applications were made with use of passive samplers to compare with the charcoal tube methods for 15 minutes. Gasoline loading processes to the tank lorry trucks at the loading stations in the petroleum products storage area. Good agreements between the results of passive samplers and those of the charcoal tubes were achieved. However, it was found that special cautions were necessary during the analysis at very low concentration levels.

Consequence Modeling Methodology for Prediction of Hazard Distance for Two-phase Flow Release from the Pressurized Chlorine Saturated Liquid Storage Tank (가압 염소포화액체 저장탱크의 2상 흐름 누출에 대한 유해위험거리의 예측을 위한 결과영향 모델링 방법론)

  • Song D. M.;Park Y. S.;Park J. K.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.7-17
    • /
    • 1998
  • This study is to develop the consequence modeling methodology for quantitative prediction of the hazard distance(or toxic buffer distance) for two-phase flow continuous releases from the pressurized chlorine saturated liquid storage tank of the chemical plant facilities. The source term modeling was peformed by the refined analysis method based on USEPA's guideline and SuperChems model self-calculation, respectively. The hazard distance was predicted for STEL, IDLH and ERPGs(ERPG-2 and ERPG-3) concentrations being used as the toxic regultaion concentration in hazard estimation. To use as hazard estimation guideline for the establishment of the emergency response planning, the effects of source characteristics and meteorological vaiations on the hazard distance was especially considered for ERPG-2 concentration.

  • PDF

A Study on Worker Exposure to Ethylene Oxide in Central Supply Sterilizing Room of Hospital (일부 종합병원 중앙공급실에서의 Ethylene Oxide 노출에 관한 연구)

  • Seo, Sang Ok;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.68-86
    • /
    • 1995
  • This study was conducted at five Ethylene Oxide(EO) sterilizing processes in hospitals located in Seoul from August 8 to August 30, 1994. The main purposes of this study were to assess the TWA(Time Weighted Average) and short term exposures to EO and to evaluate factors affecting EO concentrations in sterilizing room. Results are summarized as follows. 1. The TWA concentrations of the sterilizing operators ranged from <0.005ppm to 3.04ppm and those of two sterilizing rooms out of five exceeded 1ppm, the Korean and ACGIH standards. 2. When the door of the sterilizer is opened at the end of the sterilization cycle, the short term concentrations of operators ranged from <0.005ppm to 11.4ppm, and those of three sterilizing room out of five exceeded 5ppm, the ACGIH short term exposure limit(STEL). The short term concentrations of area samples ranged from 0.24ppm to 49.2ppm and those of four sterilizing room out of five exceeded 5ppm. 3. Factors affecting EO exposure level were aeration type, the location of storage site for sterilized item, amount of gas, use period of sterilizer(p<0.005). 4. Following recommendations are suggested to minimize exposure to EO. The use of EO gas should be reduced by using another available sterilization methods, and the sterilizers and gas tank storage site should be isolated from, other work areas. Combination of local and general ventilation system should be installed. Metal carts or baskets for sterilization load should be used, and work environment and medical monitoring should be performed regularly.

  • PDF

Combustion Emission Gas Analysis and Health Hazard Assessment about P. densiflora and Q. variabilis Surface Fuel Beds (소나무, 굴참나무 낙엽의 연소 방출가스 분석 및 건강 위험성 평가)

  • Kim, Dong-Hyun;Kim, Eung-Sik;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.24-31
    • /
    • 2009
  • Based on fallen leaves of major Korean conifer species 'Pinus densiflora' and major Korean broadleaved species 'Quercus variabilis', this study sought to identify combustion emission gas types and measure their concentration by means of FTIR (Fourier Transform Infrared) spectrometer. As a result, it was found that there were total 13 types of combustion gas detected from fallen leaves of Pinus densiflora and Quercus variabilis, such as carbon monoxide, carbon dioxide, acetic acid, butyl acetate, ethylene, methane, methanol, nitrogen dioxide, ammonia, hydrogen fluoride, sulfur dioxide and hydrogen bromide. Notably, nitrogen monoxide was additionally detected from fallen leaves of Quercus variabilis. It was found that the overall concentration of combustion gas emitted from the fallen leaves of Pinus densiflora was 4.5 times higher than that from fallen leaves of Quercus variabilis. Particularly, it was found that emission concentration of some combustion emission gas types like carbon monoxide, carbon dioxide and butyl acetate exceeded the upper limit of their time-weighted average (TWA, ppm), while the emission concentration of carbon monoxide and carbon dioxide exceeded their short-term exposure limit (STEL, ppm) for both species. Thus, it was found that carbon monoxide and carbon dioxide have higher hazard to health than other gas types, because these two gas types account for higher than 99% of overall gas emission due to combustion of surface fire starting from litter layer in forest.

Study on the Chemical Management - 1. Chemical Characteristics and Occupational Exposure Limits under Occupational Safety and Health Act of Korea (화학물질 관리 연구-1. 산업안전보건법상 관리 화학물질의 특성과 노출기준 비교)

  • Park, Jihoon;Ham, Seunghon;Kim, Sunju;Lee, Kwonseob;Ha, Kwonchul;Park, Donguk;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.45-57
    • /
    • 2015
  • Objectives: This study aims to compare the physicochemical characteristics, toxicological data with Occupational Exposure Limits (OELs) of chemicals under the Occupational Safety and Health Act(OSHA) regulated by the Ministry of Employment and Labor of Korea. Methods: Information on chemicals which have OELs on physicochemical characteristics and toxicological data was collected using Material Safety Data Sheet(MSDS) from Korea Occupational Safety and Health Agency(KOSHA) and the Korea Information System for Chemical Safety Management(KISChem) in 2014. Statistical analyses including correlation and simple regression were performed to compare the OELs with chemical characteristics including molecular weight, boiling point, odor threshold, vapor pressure, vapor density, solubility and octanol-water partition coefficient(OWPC) and toxicological data such as median lethal dose($LD_{50}$) and median lethal concentration($LC_{50}$). Results: A total of 656 chemicals have OELs under OSHA in Korea. The numbers of chemicals which have eight-hour time weighted average(TWA) and short term exposure limits(STEL) are 618 and 190, respectively. TWA was significantly correlated with boiling point and STEL was only correlated with vapor pressure among physicochemical characteristics. Solubility and OWPC between "skin" and "no skin" substances which indicate skin penetration were not significantly different. Both $LD_{50}$ and $LC_{50}$ were correlated with TWA, while the $LC_{50}$ was not with STEL. As health indicators, health rating and Emergency Response Planning Guidelines(ERPG) rating as recommended by the National Fire Protection Association(NFPA) and American Industrial Hygiene Association(AIHA) were associated with OELs and reflect the chemical hazards. Conclusions: We found relationships between OEL and chemical information including physicochemical characteristics and toxicological data. The study has an important meaning for understanding present regulatory OELs.