• Title/Summary/Keyword: STATCOM power system

Search Result 147, Processing Time 0.028 seconds

Voltage fluctuation compensation method for power supply system of high-speed rail using Fuzzy controller (퍼지제어기를 적용한 고속철도 급전 계통의 전압 변동 보상기법)

  • Kim, Jong-Kyu;Yang, Hyun-Suk;Lee, Dong-Myung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.491-492
    • /
    • 2013
  • 본 연구는 STATCOM을 이용하여 고속철도 급전 계통의 전압 변화를 보상하는 기법에 관한 것이다. 기존의 PI 제어기를 이용한 제어기법를 대신하여 본 연구에서는 퍼지제어기(FLC) 적용을 제안하며, 퍼지제어기와 PI제어기의 제어결과를 비교한다. 퍼지제어기를 통해 내부 파라미터 변동이나 외부의 환경 변화 등 계통의 변화시에 정상상태 편차, 정상상태 도달 시간 등을 최소화 시킬 수 있음을 보인다.

  • PDF

Dynamic Characteristic Analysis of 3-Level Half-bridge SSSC (3-레벨 반브리지로 구성된 SSSC의 동특성 분석)

  • 박상호;하요철;백승택;김희중;한병문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2001
  • This paper proposes a SSSC based on 3-level half-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-but power system. The proposed SSC has six 3-level half-bridge inverters per phase, which operates in PWM mode. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction (무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC)

  • Pyo, Soo-Han;Park, Jang-Hyun;Oh, Jeong-Sik;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This paper propose a new form of UPQC (Unified Power Quality Compensator) to compensate the current and voltage quality problems of nonlinear loads. The conventional UPQC system consists of a series inverter, a parallel inverter, and a common DC link. A new type of UPQC proposed is a parallel compensator with SVC (Static Var Compensator) added to compensate for the wide compensation range and low DC link voltage. The parallel inverter compensates the reactive power generated by the nonlinear load, and the series inverter compensates the sag and swell generated at the power supply side.

Optimal Coordination and Penetration of Distributed Generation with Shunt FACTS Using GA/Fuzzy Rules

  • Mahdad, Belkacem;Srairi, Kamel;Bouktir, Tarek
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • In recent years, integration of new distributed generation (DG) technology in distribution networks has become one of the major management concerns for professional engineers. This paper presents a dynamic methodology of optimal allocation and sizing of DG units for a given practical distribution network, so that the cost of active power can be minimized. The approach proposed is based on a combined Genetic/Fuzzy Rules. The genetic algorithm generates and optimizes combinations of distributed power generation for integration into the network in order to minimize power losses, and in second step simple fuzzy rules designs based upon practical expertise rules to control the reactive power of a multi dynamic shunt FACTS Compensator (SVC, STATCOM) in order to improve the system loadability. This proposed approach is implemented with the Matlab program and is applied to small case studies, IEEE 25-Bus and IEEE 30-Bus. The results obtained confirm the effectiveness in sizing and integration of an assigned number of DG units.

A Modelling and Analysis of SSSC and UPFC in Static Analysis of Power Systems (IPLAN을 사용한 SSSC와 UPFC의 모델링과 정태해석에 미치는 영향 분석)

  • 김덕영;조언중;이군재;이지열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.15-19
    • /
    • 2001
  • This paper presents an modelling and analysis of SSSC and UPFC in static analysis of power systems. SSSC is used to control active power flow in transmission lines by controlling the phase angle of the injected voltage source which is in rectangular to the line current. UPEC is used to control the magnitude and phase of the injected voltage sources which are connected both in series and in parallel with the transmission line to control power flow and bus voltage. To compare the effect of SSSC and UPFC in power system static analysis, the PSS/E simulation program is used. As the FACTS device model such as SSSC and UPFC is not provided in PSS/E yet, an equivalent load model is used. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to improve bus voltage than SSSC in power system static analysis.

  • PDF

Simulator Development and Performance Analysis of Wind Power System Interconnected with Induction Generator (농형유도발전기로 연계된 풍력발전시스템의 시뮬레이터 개발)

  • Lee, Dong-Geun;Lee, Doo-Young;Han, Byung-Moon;Ko, Jong-Sun;Choi, Nam-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.173-176
    • /
    • 2007
  • 본 논문에서는 풍속이 가변하는 상황에서 풍력 발전 시스템의 동작을 모의 할 수 있는 풍력 터빈 시뮬레이터를 설계 구현하였다. 실제 풍속과 회전 속도를 실시간으로 입력받으며, 토크 계산에 필요한 블레이드의 효율을 주속비에 관한 함수로 처리하여 사용함으로써 복잡한 조작 없이 가변 풍속조건에서 블레이드에 의한 토크입력을 모의할 수 있게 하였다. 또한 풍력터빈 시뮬레이터를 이용하여 농형 유도발전기식 풍력발전시스템을 구성하여 계통에 연계하였을 경우 발생되는 무효전력을 보상하기 위해 펄스 다중화 보조브리지회로를 이용한 새로운 구조의 36-펄스 전압원 컨버터방식의 실시간 무효전력보상기(STATCOM)를 적용하였다. 그리고 동작특성을 분석하고 제어시스템의 성능해석을 위하여 시뮬레이션 프로그램인 EMTDC/PSCAD를 이용한 시뮬레이션을 실시하였으며, 축소모형 하드웨어 실험을 통해 실험을 통한 분석을 실시하였다.

  • PDF

Development of All-In-One Type Energy Storage System(ESS) for Distribution Network (배전용 일체형 에너지저장장치(ESS) 개발)

  • Park, Minjun;Seo, Jungwon;Hwang, Kwangkyu;Park, Juhyun;Jang, Jeahoon;Kim, Heejung
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.302-303
    • /
    • 2017
  • 본 논문에는 250KW급 에너지저장장치(ESS)를 이용한 일체형 배전용 계통연계 전력변환 장치를 제안한다. ESS는 전력 불안정에 따른 전력 손실을 줄이고 여름과 겨울, 낮과 심야시간의 전력수요 차이로 인한 전력수습의 불안정을 조절할 수 있는 최적의 수단이다. 제안된 배전용 일체형 ESS란 수용가 및 분산형 전원이 연계된 배전선로에 연결되어 조화롭고 안정적으로 운전될 수 있는 전력변환 장치이다. 충전된 전력을 효율적으로 계통으로 보내기 위하여 배전선로 전압제어기술(Statcom) 개발과 분산형 전원의 유 무효 전력제어, 역률 보상기(PF) 등의 기능을 적용하여 시뮬레이션, 프로토 타입 및 현장 시험을 이용하여 성능을 검증하였다.

  • PDF