• Title/Summary/Keyword: SS removal

Search Result 475, Processing Time 0.027 seconds

The study of chemical treatment of pulp mill bleaching waste liquor using sea water (해수를 이용한 펄프공장 폐액의 화학적 처리에 관한 연구)

  • 정병곤;이헌모;윤종호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.1
    • /
    • pp.39-48
    • /
    • 1997
  • The study was conducted to know the possibility that the removal efficiency of organic and suspended solids(SS) could be increased by suppling of sea water and the optimum amount of sea water to be supplied treat bleaching waste water by lime coagulation settlement at pulp mill process. When the lime dosage was increased, the removal efficiency of COD and SS in the waste water was increased based on the removal efficiency of COD and SS. The lime dosage and removal efficiency was increased proportionally with the lime concentration of 4,000 mg/l, but the increase of removal efficiency was presented slightly above the 4,000mg/l. It was evaluated that the removal efficiencies of COD and SS could be increased and the requirement of lime dosage could be decreased by the sea water supplement. The removal efficiency of SS was most increased when the sea water supplement was 10% or more in the waste water. The removal efficiencies of COD was the best at 4% sea water excepting the dilution efficiency by sea water supplement.

  • PDF

Analysis of Temperature Effect on Activated Sludge Process at Cheong-Gye Cheon Sewage Treatment Plant (활성오니공법에 있어서 수온이 처리효율에 미치는 영향에 관한 분석 -청계천 하수종말처리장에 대하여-)

  • 이은경
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.9-20
    • /
    • 1981
  • This study was performed to determine the correlationship between temperature and overall removals of BOD, SS and to demonstrate the effect of temperature on treatment performance. These data for a period from February 1, 1977 to January 31, 1980 were obtained from the Cheong-Gye Cheon Sewage Treatment plant. The results of correlation and stepwise multiple regression analysis were as follows. 1) Secondary effluent BOD and SS showed negative correlationship with water temperature, with correlation coefficient of -0.1710, and -0.1654 respectively. 2) Correlation coefficient of BOD, SS removal rate and water temperature were 0.1823 and 0.0429 respectively. 3) Regresion equation for estimate of BOD removal rate was as follows $\widehat{Y}_1$ (BOD removal rate)=63.9994+0.5442X(water temperature). And BOD removal rate showed non significant change according to the water temperature. 4) Regression equation for estimate of SS removal rate was as follows $\widehat{Y}_2$ (SS removal rate)=61.6881+0.1514X(Water temperature). And SS removal rate showed non significant change according to the water temperature. 5) According to the Stepwise Multiple Regression analysis, water temperature ranked second order in the BOD removal rate estimation and the equation was as follows $\widehat{Y}_1$ (BOD removal rate)=69.7398+0.2665 $X_1$ (Primary effluent BOD)+0.3562 $X_2$ (Water temperature)-0.0122 $X_3(Flow)+4413.271X_4$ (Organic Loading).

  • PDF

Effects of Plant on Pollutant Removal Rate n Surface-flow Constructed Wetlands (자유수면형 인공습지에서 식물식재 유무가 처리효율에 미치는 영향)

  • Ham, Jong-Hwa;Kim, Hyung-Joong;Kim, Dong-Hwan;Hong, Dae-Byuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.85-91
    • /
    • 2011
  • Three different types of wetlands (unplanted wetland, reed planted wetland, cattail planted wetland) were constructed at the mouth of Seokmoon reservoir with 910 $m^2$ each to examine the effects of wetland plant on pollutant removal rate in constructed wetland, and operated for 9 years (2002~2010). Water depth of the wetland was maintained at 0.3~0.5 m, flow rate was about 40~200 $m^3$/day, and retention time was managed at about 1~5 days. There was no difference in removal rate of SS, TN, and TP between reed wetland and cattail wetland. Removal rate of SS and TN in planted wetland with reed and cattail were higher than unplanted wetland, whereas removal rate of TP in unplanted wetland was higher then planted wetland. The monthly variation of removal rate in planted wetlands was high compared with unplanted wetland. From the long term monitoring results, SS and TN removal rates of period3 (2008~2010) were higher than period1 (2002~2004) in planted wetland, whereas TP removal rate was decreased as time goes on. Overall, pollutant removal rate in constructed wetland was more influenced by existence of plants than by plant species. Although constructed wetland is operated long term period, SS, TN, and TP removal rate (SS 90 %, TN 60 %, TP 40 %) can be maintained high values.

A Study on the Removal of Grease and Oill in the Treatment Plant (하수처리장의 유지제거에 대한 연구)

  • 박재효
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media (여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감)

  • Kim, Seongbeom;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.214-219
    • /
    • 2017
  • We analyzed the water quality of first flush and rainfall runoff from a building rooftop, and investigated the removal of suspended solids (SS) in first flush using various media to develop a first flush filtration system. Particle size distribution exhibited most of particles in first flush from the rooftop ranged from 10 to 30 ${\mu}m$. SS concentrations maxed in 10~20 min and decreased afterwards. Dissolved organics and inorganic materials in runoff also showed highest levels in first flush (10 min). Filtration tests using anthracite (AC), polyurethane (PU), polypropylene (PP) showed about 50% of SS removal during the first 10 min operation, but the removal rates dramatically decreased after 20 min of filtration. Based upon the results from rinse and run cycle tests, only AC could achieve nice cycles without distinct decease of SS removal. SS removal rates increased with higher depth of media bed and lower flowrate. The system achieved over 50% of SS removal with a media depth of 30 cm and flowrate < 12 L/min.

COD, SS and Turbidity Removal of Paper Wastewater Using DAE(Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 제지폐수의 COD, SS 및 탁도 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.246-253
    • /
    • 2005
  • The supernatant treatment of recovery process of raw materials of paper plant was studied using DAF (Dissolved Air Flotation) system. We investigated the removal efficiency (COD, SS and turbidity) of the DAF process. The effects of parameters such as A/S ratio, pressure, flotation conditions, coagulant concentration, mixing conditions, size and ratio of packing and nozzle type were examined. The results showed that the optimum A/S ratio and pressure were 0.058 and 4.5-5 atm, respectively. Injection times of pressurized water around 30 s and flotation times around 10 min appeared to be optimal for the DAF operation. Anion polymer addition improved the removal of COD, SS and turbidity. The smaller size and the more packing ratio were enhanced the removal efficiencies. The order of performance of nozzle was full cone > flat > assemble type.

Suspended Solids Removal Performance of a Foam Fractionator with Different Operating Conditions in Seawater (해수 환경에서 포말분리기 운전 조건에 따른 고형물 제거 특성)

  • Seo, Junhyuk;Lee, Jaeman;Kim, Bongjae;Kim, Pyongkih;Kim, Youhee;Park, Jeonghwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.3
    • /
    • pp.328-337
    • /
    • 2022
  • This study investigated the removal performance of a foam fractionator under seawater conditions. The foam fractionator was tested using a 3×3×3 factorial design for operating conditions by combining different solids concentrations (SS; 1, 5, and 10 mg·L-1), surface air velocities (SAV; 1.1, 1.5, and 2.1 cm·sec-1), and hydraulic residence times (HRT; 1, 3, and 6 min) at 16℃. Performance parameters such as daily solids removal rate and efficiency were measured, and a multi-regression model equation was developed accordingly. The daily solids removal rate and removal efficiency varied with the experimental conditions and ranged from 0.14-2.33 g-solids·m-3-air·day-1 and 8.9-96.7 %, respectively. Overall, the daily solids removal rate increased with increasing SS and SAV and decreasing HRT, whereas the removal efficiency increased with increasing SAV and HRT and decreasing SS. The daily solids removal rate (g-solids·m-3-air·day-1) of the foam fractionator for SAV (cm·sec-1), SS (mg·L-1) and HRT (min) were described by the following multi-regression model: Daily solids removal rate [f(z)]=-0.118+0.422SAV+0.094HRT+0.141SS (r2=0.873).

SS Removal-rate Efficiency of Storm-water Detention Storage Tank Depending upon Length, Inside Training Wall and Gravel Filling (우수저류조의 형상과 도류벽 및 자갈채움에 따른 SS 제거효율)

  • Lee, Jong Tae;Seo, Hong Joon;Seo, Kyung A
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.655-667
    • /
    • 2009
  • An experimental study is performed on reducing the pollutants supplied by storm water through enhancing efficiency of SS from the detention storage tank where CSOs are kept temporarily before discharge to the receiving water system. SS removal efficiency is investigated in accordance with various conditions of the detention pond-such as its length, the existence of training wall, and the use of gravel filling. The removal efficiency is strongly affected by the detention pond's length until the critical falling distance of the suspended solids is reached. For cases where the tank has a length longer than this critical condition, the removal rate shows less sensitivity. To enhance the SS removal efficiency of tanks of shorter than the critical length, we studied alternative types of tank in which inside training walls are installed. The results showed improvement of 14 to 37% in removal efficiency in 2hours detention(2 training walls). The important factor in achieving a high SS removal rate is ensuring the critical length of the detention pond, but for the cases where the basin length cannot be guaranteed, baffles or a gravel filling scheme may be introduced to attain considerable efficiency. The results of studying and comparing different storage tank conditions show that, in terms of elimination efficiency, a storage tank with gravel filling and training walls > a storage tank with gravel filling > a storage tank with training walls > an empty tank. The experimental results should contribute to development of related further research, by empirically verifying the already assumed importance of critical falling distance, training walls, and gravel filling schemes.

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

Advanced Wastewater Treatment Using Biofilter System with Floating Media under Alternative Flow (유로변경식 부상여재 생물여과시스템을 이용한 하수고도처리)

  • Ryu, Hong-Duck;Lee, Jeong-Hun;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.250-257
    • /
    • 2006
  • The objective of this study is to propose an alternative process for the small sewage treatment plants in rural communities. A biofilter has been used for biological wastewater treatment, which is becoming the alternative to the conventional activated sludge system. The proposed process used in this study, which is packed with floating media (i.e. expanded polystylene), has advantages of biofilter system and alternative flow system and they are incorporated into one process. Pilot and bench scale studies were performed using domestic wastewater. In the results of pilot plant study, it was observed that the stable effluent water quality was achieved and it met the present effluent criteria of suspended solid (SS), organic matters, T-N and T-P. In the study for determination of the cycle of backwashing, it was observed that the cycle of backwashing depended on BOD loading rates of influents. In the BOD loading rates of $0.5kg\;BOD/m^3{\cdot}day$ and $1.0kg\;BOD/m^3{\cdot}day$, the backwashing cycle of 28 hour and 16 hour were needed, respectively. The optimum backwashing time was 120~80 seconds at the media expansion rate of 50%. In the removal of SS, organic matters, T-N and T-P, SS removal was rather achieved by physical filtration than biological mechanism and the removal of organic matters except for SS, T-N and T-P were mainly rather achieved by biological mechanism than physical filtration. In bench-scale study, the effects of recirculation rate was investigated on removal of SS, TCOD, T-N and T-P. It was observed that the recirculation made removal efficiencies of SS, TCOD, T-N and T-P increased. Especially, in T-N removal, the increase of T-N removal efficiency of 40% was observed in the reicirculation rate of 1Q compared with 0Q.