• 제목/요약/키워드: SS

검색결과 3,791건 처리시간 0.03초

DAF(Dissolved Air Flotation)를 이용한 제지폐수의 COD, SS 및 탁도 제거 (COD, SS and Turbidity Removal of Paper Wastewater Using DAE(Dissolved Air Flotation))

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.246-253
    • /
    • 2005
  • The supernatant treatment of recovery process of raw materials of paper plant was studied using DAF (Dissolved Air Flotation) system. We investigated the removal efficiency (COD, SS and turbidity) of the DAF process. The effects of parameters such as A/S ratio, pressure, flotation conditions, coagulant concentration, mixing conditions, size and ratio of packing and nozzle type were examined. The results showed that the optimum A/S ratio and pressure were 0.058 and 4.5-5 atm, respectively. Injection times of pressurized water around 30 s and flotation times around 10 min appeared to be optimal for the DAF operation. Anion polymer addition improved the removal of COD, SS and turbidity. The smaller size and the more packing ratio were enhanced the removal efficiencies. The order of performance of nozzle was full cone > flat > assemble type.

SS-OCT용 정현파 및 트리거 펄스 발생기 (Sine-wave and Trigger Pulse Generator for SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

해양환경 중에서 SS400강재의 간극부식방지 특성에 관한 연구 (Study on the Characteristics of Crevice Corrosion Prevention of SS 400 in Marine Environment)

  • 임우조;정기철;구영필;윤병두
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.152-157
    • /
    • 2001
  • This paper was studied on the characteristics of crevice corrosion prevention of SS 400 in marine environment. In NaCl solution, polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 applied cathodic protection and non cathodic protection was measured according to the NaCl concentration. The main results obtained are as follows : The weight loss rate of Al-alloy galvanic anode was increased as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of Al-alloy galvanic anode become decreased. The protective potential of SS 400 used Al-alloy galvanic anode becomes more cathodic polarization with increasing concentration of NaCl solution. Effects of oxygen on the weight loss rate of Al-alloy sacrificial anode for cathodic protection as the concentration of 3.5% NaCl solution become sensitive than that of 0% NaCl solution.

  • PDF

Molecular Dynamic Study of A Polymeric Solution (II). Solvent Effect

  • Oh In-Joon;Lee Young-Seek;Ree Tai-Kyue
    • Bulletin of the Korean Chemical Society
    • /
    • 제4권2호
    • /
    • pp.87-91
    • /
    • 1983
  • Molecular dynamic method has been applied to a single polymer chain immersed in a solvent. The interactions for the pairs, of two solvent molecules (SS), of a chain element and a solvent molecules (CS), and of two non-neighbor chain elements (CC) are given by the Lennard-Jones potential, and the interaction between two bonded chain elements is given by a harmonic potential. We changed the CS interaction parameter ${\varepsilon}_{CS}$ to 0.5, 1.0 and 2.0 times of the SS interaction ${\varepsilon}_{SS}$. We calculated the pair correlation functions for the SS, CS, and CC pairs, end-to-end distance and radius of gyration with the varying ${\varepsilon}_{CS}$ parameters. The results showed that a phase separation occurs between the polymer and solvent in the 0.5 system where ${\varepsilon}_{CS}$ = 0.5 {\varepsilon}_{SS}$. The autocorrelation functions for end-to-end distance and radius of gyration were also calculated.

활성오니공법에 있어서 수온이 처리효율에 미치는 영향에 관한 분석 -청계천 하수종말처리장에 대하여- (Analysis of Temperature Effect on Activated Sludge Process at Cheong-Gye Cheon Sewage Treatment Plant)

  • 이은경
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.9-20
    • /
    • 1981
  • This study was performed to determine the correlationship between temperature and overall removals of BOD, SS and to demonstrate the effect of temperature on treatment performance. These data for a period from February 1, 1977 to January 31, 1980 were obtained from the Cheong-Gye Cheon Sewage Treatment plant. The results of correlation and stepwise multiple regression analysis were as follows. 1) Secondary effluent BOD and SS showed negative correlationship with water temperature, with correlation coefficient of -0.1710, and -0.1654 respectively. 2) Correlation coefficient of BOD, SS removal rate and water temperature were 0.1823 and 0.0429 respectively. 3) Regresion equation for estimate of BOD removal rate was as follows $\widehat{Y}_1$ (BOD removal rate)=63.9994+0.5442X(water temperature). And BOD removal rate showed non significant change according to the water temperature. 4) Regression equation for estimate of SS removal rate was as follows $\widehat{Y}_2$ (SS removal rate)=61.6881+0.1514X(Water temperature). And SS removal rate showed non significant change according to the water temperature. 5) According to the Stepwise Multiple Regression analysis, water temperature ranked second order in the BOD removal rate estimation and the equation was as follows $\widehat{Y}_1$ (BOD removal rate)=69.7398+0.2665 $X_1$ (Primary effluent BOD)+0.3562 $X_2$ (Water temperature)-0.0122 $X_3(Flow)+4413.271X_4$ (Organic Loading).

  • PDF

하수처리장의 유지제거에 대한 연구 (A Study on the Removal of Grease and Oill in the Treatment Plant)

  • 박재효
    • 한국환경보건학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

겹치기 마찰교반접합된 Inconel 600/SS 400 합금의 미세조직과 기계적 특성 평가 (Evaluation of Microstructure and Mechanical Properties of Friction Stir Lap Jointed Inconel 600/SS 400)

  • 송국현
    • 한국재료학회지
    • /
    • 제22권3호
    • /
    • pp.123-129
    • /
    • 2012
  • The microstructures and mechanical properties of friction stir welded lap joints of Inconel 600 and SS 400 were evaluated; friction stir welding was carried out at a tool rotation speed of 200 rpm and welding speed of 100 mm/min. Electron back-scattering diffraction and transmission electron microscopy were introduced to analyze the grain boundary characteristics and the precipitates, respectively. Application of friction stir welding was notably effective at reducing the grain size of the stir zone. As a result, the reduced average grain size of Inconel 600 ranged from $20{\mu}m$ in the base material to $8.5{\mu}m$ in the stir zone. The joint interface between Inconel 600 and SS 400 showed a sound weld without voids and cracks, and MC carbides with a size of around 50 nm were partially formed at the Inconel 600 area of lap joint interface. However, the intermetallic compounds that lead to mechanical property degradation of the welds were not formed at the joint interface. Also, a hook, along the Inconel 600 alloy from SS 400, was formed at the advancing side, which directly brought about an increase in the peel strength. In this study, we systematically discussed the evolution of microstructures and mechanical properties of the friction stir lap joint between Inconel 600 and SS 400.

접촉산화법에 의한 소각로 배출폐액의 처리에 관한 연구 (A Study on the Treatment of Incinerator Wastewater with Biofilm Reactor)

  • 신대윤;서동우
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.92-97
    • /
    • 2000
  • The treatment of the washout from small scale incinerator was performed physically, chemically and biologically. The results are as follows. 1. SS, FS removal efficiency of washout wastewater from incinerator was 67.4%, 37.4%, while SS, FS of sewage wastewater was removed 63.2% 35.4% respectively. 2. The optimal conditions for chemical coagulation turned out to be pH 7.5, alum(Al2O3 10%) 30ml/ι and polyelectrolyte(A-601P 0.1%) 4ml/ι. SS 86%, FS 89.5%, BOD 42.5% and CODMn, 63.5% was removed and the removal efficiency of some metals are shown as Pb 93.5%, Zn 86.5% and Fe 80.6%. The concentration of the effluent was SS 9mg/ι, BOD 98.4mg/ι, and CODMn 138.4mg/ι. 3. The removal efficiency in treating washout wastewater of incinerator through HBC-briquet media was getting higher with increasing HRT, and mixed wastewater with 1:1, 1:2 ratio could be met up to the standard limit with higher HRT than 12hr. Under the condition of 1:2 mix ratio and HRT 24 hr, removal efficiency of SS, BOD, CODMn, T-N and T-P was 92.1%, 90%, 87%, 48.2% and 48%, respectively, and the concentration of treated wastewater was SS 2.9 mg/ι, BOD 10.3mg/ι, CODMn 14.1mg/ι, T-N 11.6 mg/ι and T-P 1.3 mg/ι, respectively.

  • PDF

SS400 용접부의 피로강도에 미치는 쇼트 피닝의 영향 (Effect of Shot Peening on the Fatigue of SS400 Weldments)

  • 김진헌;구병춘;김현규;정성균
    • 한국철도학회논문집
    • /
    • 제12권6호
    • /
    • pp.895-901
    • /
    • 2009
  • 철도 차량 대차 프레임은 주로 용접을 이용하여 제작되고 있는데 용접부에서의 피로파괴는 늘 문제가 되어왔다. 용접부의 피로강도를 향상시키기 위한 여러 방법 중 본 연구에서는 쇼트 피닝을 적용하였다. 철도 구조물에 많이 사용되는 소재의 하나인 SS400 판재를 이용하여 용접시편을 만들어 쇼트 피닝과 후열처리 유무에 따른 피로특성을 분석하였다. 피로시험결과에 의하면 쇼트 피닝은 피로강도를 향상시키는데 매우 효과적이었고 후열처리는 피로강도를 도리어 저하시키는 것으로 나타났다.

페이스북 활용 수업에서 대학생이 인식한 실재감이 학습몰입경험에 미치는 영향 (A Study on the Effects of Presence and Learning Flow Experience at University Classes Using Facebook)

  • 박혜진;유병민;차승봉
    • 농촌지도와개발
    • /
    • 제22권3호
    • /
    • pp.321-332
    • /
    • 2015
  • For the purpose of enhancing the use of social service in classrooms, this research focuses on the relationships between presence and learning flow, key words in the analysis of college classes using Facebook. The results of this study are as follow. First, social presence(${\ss}=.33$, p=.000), emotional presence(${\ss}=.29$, p= .000), cognitive presence(${\ss}=.20$, p= .010) were found to be significant according to cognitive flow experience the result of analysis of multiple regression. all regression coefficients were positive. Second, emotional presence(${\ss}=.42$, p=.000) and social presence(${\ss}=.27$, p=.000), cognitive, presence(${\ss}=.17$, p=.015) were found to be significant according to emotional flow experience the result of analysis of multiple regression. all regression coefficients were positive. Third, social presence(${\ss}=.37$, p=.000) of the three variables were found to be significant according to behavioral flow experience the result of analysis of multiple regression.