• Title/Summary/Keyword: SQUARE

Search Result 15,958, Processing Time 0.043 seconds

Design-based Properties of Least Square Estimators in Panel Regression Model (패널회귀모형에서 회귀계수 추정량의 설계기반 성질)

  • Kim, Kyu-Seong
    • Survey Research
    • /
    • v.12 no.3
    • /
    • pp.49-62
    • /
    • 2011
  • In this paper we investigate design-based properties of both the ordinary least square estimator and the weighted least square estimator for regression coefficients in panel regression model. We derive formulas of approximate bias, variance and mean square error for the ordinary least square estimator and approximate variance for the weighted least square estimator after linearization of least square estimators. Also we compare their magnitudes each other numerically through a simulation study. We consider a three years data of Korean Welfare Panel Study as a finite population and take household income as a dependent variable and choose 7 exploratory variables related household as independent variables in panel regression model. Then we calculate approximate bias, variance, mean square error for the ordinary least square estimator and approximate variance for the weighted least square estimator based on several sample sizes from 50 to 1,000 by 50. Through the simulation study we found some tendencies as follows. First, the mean square error of the ordinary least square estimator is getting larger than the variance of the weighted least square estimator as sample sizes increase. Next, the magnitude of mean square error of the ordinary least square estimator is depending on the magnitude of the bias of the estimator, which is large when the bias is large. Finally, with regard to approximate variance, variances of the ordinary least square estimator are smaller than those of the weighted least square estimator in many cases in the simulation.

  • PDF

Clinical Study on Wrist Ganglion by Newly Transformed Centro-Square Acupuncture·Moxibustion (완관절(腕關節) 결정종(結節腫)에 대한 배담(排痰)·양자침구치료(揚刺鍼灸治療)의 임상적(臨床的) 관찰(觀察))

  • Kim, Kee-Hyun
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • Objectives : Wrist ganglion is one of the most common diseases on the wrist joint. So far acupuncture, medication, drainage and local anesthetic excision therapy have been used for this disease, but the development of more effective treatment method is being expected because of frequent recurrence and side effect. Considered that most ganglion is polycystic, on the basis of classic centro-square acupuncture, newly transformed centro-square acupuncture was applied to this report. Methods : All the patients with wrist ganglion was divided into two groups. Newly transformed centro-square acupuncture was app(ied to one group composed of 11 patients and classic centro-square acupuncture to the other group with 19 patients. Classic centro-square acupuncture is made up of slanting and straight insertion. the former is a method that tips of 4 needles are inserted from the outersurface of wrist ganglion oriented to the center of the ganglion, the latter is that tip of one needle is inserted on the center of the ganglion straightly. In the newly transformed centro-square acupuncture, straight insertion of dry needle was taken place of by syringe needle in order to drain phlegm. In this report, classic and newly transformed centro-square acupuncture were used somewhat differently from original ones. Moxibustion was applied after removing all the needles. In newly transformed centro-square acupuncture, moxibustion was also applied after drainage of phlegm and slanting insertion. Results : 1. Wrist ganglion was frequently developed around the acupoint of Tae-Yeon(Tai Yuan, LU9) and Yang-Ji(Yang Chi, TE4) and the difference between occurrence of development on the left and right hand had no significancy. 2. The mean number of treatment for recovery : The newly transformed centro-square acupuncture had fewer treatment than classic one. 3. The newly transformed centro-square acupuncture was more effective than classic one. 4. As a result of following up 6 to 72 months after wrist ganglion had been eliminated, there was no recurrence. Conclusion : In the treatment of wrist ganglion, newly transformed centro-square acupuncture can be regarded as more useful method in the clinical practice, because it has comparatiely shorter duration of treatment and is more effective.

  • PDF

Revision Volume of Square-inch-spoon, Jeon-bi and Firmiana-Seed-sized Pill Preparations in 『Treatise on Cold Damage Diseases』 (『상한론』에서 산제의 방촌비와 전비, 환제의 오동자대 크기 수정치)

  • Kim, In-Rak
    • The Korea Journal of Herbology
    • /
    • v.37 no.5
    • /
    • pp.75-81
    • /
    • 2022
  • Objectives : In 『Treatise on Cold Damage Diseases』, the volume of preparation dosage measured in Hap was 6.5mL. This study aimed to confirm that a square-inch-spoon, which measures powder preparation dosage, was 1/3 Hap, and that Jeon-bi was 1/8 square-inch-spoon. Based on these values, this study also aimed to adjust the diameter of Firmiana-Seed-sized pill preparation, currently known as 6.5mm, so that one square-inch-spoon of powder preparation creates 16 pills. Methods : Calculated the ratio between the floor areas of square-inch-spoon and Jeon-bi and measured the ratio of volume; assumed that powder preparations were stacked as much as possible in the shape of a square pyramid when scooped comfortably, then calculated the slopes of 1/3 Hap and 1/4 Hap; measured the volumes of powdered Oryeongsan and Lijungwhan in square-inch-spoon and Jeon-bi; created the powders into Firmiana-Seed-sized pill preparation; adjusted the diameter of Firmiana Seed so that 16 pills could be created. Results : Inferring from the floor areas, the volume of square-inch-spoon is 9.2 times that of Jeon-bi; one square-inch-spoon should be 1/3 Hap for the powder to reach its maximum slope of 47° and, according to actual measurement of powder preparations, reach its maximum volume; when created into Firmiana-Seed-sized pill preparations, one square-inch-spoon should be 1/3 Hap so that approximately 16 pills were created. Conclusions : One square-inch-spoon of powder preparation was 1/3 Hap(2.17mL), Jeon-bi was 1/8 square-inch-spoon(0.27mL), and the diameter of Firmiana-Seed-sized pill preparation was 5.5mm.

국내 바이러스 매개 식중독의 발생추이 및 안전관리

  • Ji, Yeong-Mi
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2006.05a
    • /
    • pp.73-96
    • /
    • 2006
  • $\square$ A nationwide surveillance including 17 provincial labs has been established $\square$ Noroviruses are involved in recent viral gastroenteritis outbreaks and sproradic viral gastroenteritis cases in Korea $\square$ Analysis of RDRP and capsid regions of norovirus strains shows that various genotypes were circulated in Korea $\square$ Early detection of outbreaks cases (2004 Jeju-cause of epidemic) $\square$ New variant or emerging strain detection: variant GII4 and GIIb $\square$ Detection of Sapoviruses from AGE patients in 2003-4

  • PDF

A study on the manufacture of extrusion square dies (평금형 CNC 가공 S/W 개발에 관한 연구)

  • 조승래
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.280-283
    • /
    • 1999
  • Square dies are widely used for hot extrusion processes with high production rate. However the design and manufacture of square dies mainly relies on experience of industrial engineers To overcome such difficulty this study develops a method of automatic generation of NC-codes for the manufacture of extrusion square dies. The result shows that the method can reduce the lead time for the design and manufacture of square dies as well as eliminating engineers ow experience.

  • PDF

A Study on the Manufacture of Extrusion Square Die (평금형 CNC 가공 S/W 개발에 관한 연구)

  • 박태원;조승래;이춘만
    • Transactions of Materials Processing
    • /
    • v.9 no.2
    • /
    • pp.179-185
    • /
    • 2000
  • Square dies are widely used for hot extrusion processes with high production rate, however, the design and manufacture of square dies mainly relies on experience of industrial engineers. To overcome such difficulty, this study presents a method of automatic generation of NC-codes for the manufacture of extrusion square dies. The result shows that the method can reduce the lead-time for the design and manufacture of square dies.

  • PDF

SQUARE CONGRUENCE GRAPHS

  • Janardhanan Suresh Kumar;Sarika M. Nair
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.3
    • /
    • pp.937-941
    • /
    • 2023
  • For each positive integer n, a square congruence graph S(n) is the graph with vertex set H = {1, 2, 3,...., n} and two vertices a, b are adjacent if they are distinct and a2 ≡ b2 (mod n). In this paper we investigate some structural properties of square congruence graph and we obtain the relationship between clique number, chromatic number and maximum degree of square congruence graph. Also we study square congruence graph with p vertices or 2p vertices for any prime number p.

FREE VIBRATION ANALYSIS OF PERFORATED PLATE WITH SQUARE PENETRATION PATTERN USING EQUIVALENT MATERIAL PROPERTIES

  • JHUNG, MYUNG JO;JEONG, KYEONG HOON
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.500-511
    • /
    • 2015
  • In this study, the natural frequencies of the perforated square plate with a square penetration pattern are obtained as a function of ligament efficiency using the commercial finite-element analysis code ANSYS. In addition, they are used to extract the effective modulus of elasticity under an assumption of a constant Poisson's ratio. The effective modulus of elasticity of the fully perforated square plate is applied to the modal analysis of a partially perforated square plate using a homogeneous finite-element analysis model. The natural frequencies and the corresponding mode shapes of the homogeneous model are compared with the results of the detailed finite-element analysis model of the partially perforated square plate to check the validity of the effective modulus of elasticity. In addition, the theoretical method to calculate the natural frequencies of a partially perforated square plate with fixed edges is suggested according to the Rayleigh-Ritz method.

An Evaluation of Bending Performance of Welded Square Tube Structures for Drive Shaft Sub Frame of BIMODAL Tram (바이모달 트램 구동축 서브프레임에 적용된 용접 사각관의 굽힘 특성 평가)

  • Ko, Hee-Young;Shin, Kwang-Bok;Lee, Jong-Hwa;Kim, Han-Su
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2200-2206
    • /
    • 2008
  • This paper describes the results of experiments on the bending behavior of welded square tube structures for drive shaft sub frame of BIMODAL Tram. The used specimens to test were two different type made of ATOS60 and ST52-3. The square tube made of ST52-3 is the non-welded structure, while the square tube made of ATOS60 is the welded structure. The welded square tube made of ATOS60 will be applied for drive shaft sub frame of BIMODAL Tram. This welded square tube could reduce the manufacturing cost in comparison of non-welded square tube. The results showed that the bending performance of welded square tube made of ATOS60 was proven, and the bending behavior was in an good agreement with that of nonlinear finite element analysis.

  • PDF

A DECOMPOSITION THEOREM FOR UTUMI AND DUAL-UTUMI MODULES

  • Ibrahim, Yasser;Yousif, Mohamed
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.6
    • /
    • pp.1563-1567
    • /
    • 2021
  • We show that if M is a Utumi module, in particular if M is quasi-continuous, then M = Q ⊕ K, where Q is quasi-injective that is both a square-full as well as a dual-square-full module, K is a square-free module, and Q & K are orthogonal. Dually, we also show that if M is a dual-Utumi module whose local summands are summands, in particular if M is quasi-discrete, then M = P ⊕ K where P is quasi-projective that is both a square-full as well as a dual-square-full module, K is a dual-square-free module, and P & K are factor-orthogonal.