• 제목/요약/키워드: SPOT-5 영상

검색결과 110건 처리시간 0.024초

투시 검사 시 체위 변화에 따른 입사표면선량의 평가 연구 (An Evaluative Study on ESD(Entrance Surface Dose) by Posture Changes for Fluoroscopy)

  • 양해두;홍선숙;박은성;성민숙;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.177-183
    • /
    • 2011
  • This study intends to investigate patients' exact exposure doses by comparatively measuring ESD (Entrance Surface Dose) with the DAP meter, which excludes scattered rays, and ESD with the Xi multifunction meter, which includes scattered rays, by posture changes for Esophagography test and UGI test. The materialwere examined through Sonialvision-SafireII SPEC overtube system. ESD was measured by using the DAP meter, and as a tool to measure ESD including scattered rays on the plane of incidence of human phantom, the Xi multifunction meter was used. The average fluoroscopic time of Esophagography test was 4.192 minutes and the average number of images was 47.7, while the average fluoroscopic time of UGI test was 6.881 minutes and the average number of images was 37.8. The ratios of the incident dose of DAP meter and the ESD of Xi meter were calculated bydividing the fluoroscopic time and the number of images by each posture change. As for Esophagography test, the dose increased by 21.6~55.5% in the fluoroscopic test and by 4.8~24.7% in the spot test. In the front spot test, however, the does increased by as little as 5.3%. As for UGI test, the dose increased by 21.1~49.5% in the fluoroscopic test and by 10.1~34.9% in the spot test. It is expected that measuring doses in consideration of scattered rays by posture changes will be an important index in evaluating and managing patients' exact exposure doses for each test above. Furthermore, it is judged that this sort of study is inevitable and desirable to reduce patients' exposure doses after all.

  • PDF

비접근 지역에 대한 SPOT 위성영상의 Pseudo영상 구성 및 센서모델 분석 (Pseudo Image Composition and Sensor Models Analysis of SPOT Satellite Imagery of Non-Accessible Area)

  • 방기인;조우석
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2001년도 춘계 학술대회 논문집 통권 4호 Proceedings of the 2001 KSRS Spring Meeting
    • /
    • pp.140-148
    • /
    • 2001
  • 일반적으로 위성영상의 센서에 대한 모델은 촬영대상지역의 지상기준점을 이용하여 결정하며, 이와 같은 지상기준점은 기존 지형도를 이용하거나 또는 지상측량에 의하여 획득한다. 그러나 지구관측위성에서 얻어진 영상의 촬영지역이 비접근 지역인 경우에는 지상측량에 의하여 지상기준점을 획득하기 어려우며, 또한 대상지역의 지형도가 제작되어 있지 않은 경우에는 실질적으로 위성영상을 이용하여 지형정보를 추출하기 어려운 실정이다. 본 논문은 지상기준점의 취득이 어려운 비접근 지역에 대한 위성영상에서 지형정보를 획득하기 위한 방법을 제시하였다. 먼저, 공선조건식을 기반으로 10개의 위성센서모델을 개발하고, 개발된센서모델의 거동을 분석하기 위하여 Space Resection 및 Space Inetersection을 통해 각각의 센서모델에 대한 적합성을 실험하였다. 이를 바탕으로 비접근 지역에 대한 지형정보를 취득하기 위하여 영상을 재구성하거나 Pseudo 영상을 제작하고, 이에 대한 센서모델의 거동 및 정확도를 분석.제시하였다. 공선조건식을 이용한 Pushbroom 위성영상의 센서모델은 투영 중심의 위치와 회전요소에 대한 6개의 외부표정요소와 상관도가 높은 회전요소($\omega$, $\phi$)를 고정된 값으로 사용하는 센서모델을 개발하였다. 비접근 지역의 영상으로부터 Pseudo 영상을 임의로 제작하여 패스내에서 중복영역을 갖도록 구성하였다. 본 연구에서 이용한 인공위성 데이터는 서로 다른 패스에서 동일한 지역을 촬영한 SPOT 영상이며, 각각의 패스에서 두 장의 연속된 영상을 이용하였다. 개발된 10개의 센서모델과 5가지의 영상 재구성 방법에 따라 비접근 지역에서의 정확도는 다르게 나타났으며, 그 중 투영중심의 위치 및 회전요소 k를 1차 함수로 표현하고 회전요소 $\omega$, $\phi$를 고정시킨 센서모델과 Pseudo 영상을 이용한 방법이 비접근 지역 60km 지점의 검사점에서 최대오차 60m의 결과를 보였다.

  • PDF

레이다 간섭기법에서 고도민감도를 활용한 지형정보 복원 (The Reconstruction of topographical data using Height Sensitivity in SAR Interferometry)

  • 김병국;정도찬
    • Spatial Information Research
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2001
  • 위성영상을 이용하여 지형도를 제작하는 새로운 방법으로 레이다 간섭기법에 관한 연구가 활발히 진행되고 있다. 레이다 간섭기법은 동일한 지역을 촬영한 두 장의 SAR 영상의 위상정보를 이용하여 표고값을 추출하는 기법으로, 기존의 SPOT과 같은 광학영상에 비하여 날씨나 시간의 제약을 받지 않고 지형정보를 얻을 수 있다는 장점을 가지고 있다. 즉, 영상취득의 유연성이 뛰어나며 광범위한 면적에 대하여 저렴한 표고데이터 추출이 가능하여 GIS에서의 활용 가능성 또한 밝다고 할 수 있다. 그러나 레이다 간섭기법은 SAR 시스템에 따라 발생하는 기하학적 왜곡으로 인해 일부지역에 대해서는 위상불구속화 알고리즘에 따라 표고값이 잘못 추정되거나 아예 그값을 얻지 못하는 단점을 가지고 있다. 본 연구에서 사용한 ERS 텐덤자료의 경우에는 산악지형에서의 수직위치 정확도가 가장 부정확했으며, 기하학적 왜곡으로는 ERS 위성의 짧은 입사각으로 인한 layover 현상이 주로 발행하였다. 위상불고속화 기법별로는 경로추적방식 알고리즘을 사용했을 경우, 산출된 표고값의 정확도는 최소제곱방식을 수행했을 경우보다 2∼5m 가량 우수하였으나 기하학적 왜곡이 발생한 지역에서의 데이터를 얻지 못하는 결과를 보였다. 이 지역에 대하여 고도민감도를 이용하여 표고값을 추정한 결과 경로추적방식의 정확도를 유지하면서 전체 영상에 대하여 표고값을 갖는 DEM을 제작할 수 있었다.

  • PDF

비점오염원 수문유출모형에 적용 가능한 위성영상의 토지피복 분류항목 설정 (Categorizing the Landcover Classes of the Satellite Imagery for the Management of the Nonpoint Source Pollutions)

  • 서동조
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.465-474
    • /
    • 2009
  • 비점오염원의 유출량을 파악하기 위하여 대상지의 토지피복 현황을 잘 파악할 수 있는 위성영상자료를 사용하려는 시도가 이루어지고 있다. 그러나 수문 유출모형에 사용되는 인자와 부합되는 토지피복 분류항목이 되지 못한 채 단순한 분류항목으로만 사용되거나, 육안 해석용으로만 적용되는 한계가 있다. 이 같은 상황에서 위성영상으로부터 수문유출 모형에 실질적으로 적용할 수 있는 토지피복 분류항목을 설정하여, 위성영상을 통한 효과적인 비점오염원 관리가 이루어질 수 있도록 하였다. 수문유출 모형에서 사용하고 있는 토지피복 항목을 파악하기 위하여 비점오염원 유출모델의 주요 인자, 선행연구에서 사용된 토지피복 항목, 그리고 국내외 각 기관에서 제시하고 있는 토지피복 분류체계에 대한 내용을 조사하였다. 이를 통해 비점오염원에 의한 원단위, 유출곡선지수의 토지피복 계수, 토양유실량 예측공식의 식생인자, Manning의 조도계수 등의 인자들이 위성영상으로부터 추출하여 적용할 수 있는 토지피복 정보임을 파악할 수 있었다. 이러한 과정을 거쳐 위성영상으로부터 수문유출모형에 적용할 수 있는 토지피복 분류항목을 설정하였다. 또한 이 결과가 우리나라의 환경에 적절한 것인지를 검증하기 위하여 국내 수문유출모형 관련 기관의 전문가로부터 토지피복 분류항목의 적정성에 대한 자문 과정을 거쳐 결정하였다. 연구대상지는 우리나라의 대표적인 습지로 비점오염원 관리체계가 필요한 우포늪의 토평천 유역을 대상지로 하였다. 토지피복 분류항목을 적용할 위성영상으로는 분광 해상도가 높은 Landsat ETM Plus 영상과 공간 해상도가 높은 SPOT-5 영상을 사용하였다.

자궁난관 조영술 검사 시 Speculum 재질에 따른 흡수선량의 변화에 관한 연구 (Research about the absorbed dose with speculum material-related in Hysterosalpingography)

  • 김연민
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • The purpose of our study was to determine the entrance surface dose and absorbed dose in ovary when using the metal speculum and plastic speculum in hysterosalpingography respectively. The examinations was performed in anthropomorphic phantom into which calibrated photoluminescence glass dosimeter were placed on symphysis pubis level surface and ovary area. We checked average fluoroscopy time and spot expose times during the hysterosalpingography. It was average fluoroscopy time 58 sec, spot expose 5 times. We divided the subjects into two different groups to used metal and plastic speculum. We measured 10 times of absorbed dose in the same condition of the anthropomorphic phantom. We compared two groups adsorbed dose on ovary with speculum material-related. The entrance surface dose on of plastic Speculum using group was average 17.23 mGy, absorbed dose on ovary was average 3.51 mGy. The entrance surface dose on ovary of metal Speculum using group was average 19.95 mGy, absorbed dose on ovary was average 4.14 mGy. Plastic speculum using group shows a decrease absorbed dose(17.9%) as compared with metal speculum using group. The method of plastic speculum using in hysterosalpingography. might provide us with lower radiation dose, especially in patients with childbearing stage.

  • PDF

3 Spot DR를 이용한 척추 전장 촬영 시 모형 왜곡도 비교를 통한 유용성 연구 (The Study of Effectiveness of 3 Spot DR for the Whole Spine Radiography with Comparison of Phantom Distortions)

  • 김상현;이미화
    • 디지털융복합연구
    • /
    • 제12권10호
    • /
    • pp.345-351
    • /
    • 2014
  • 본 연구의 목적은 평면 모형의 가로, 세로 비율과 가상 cobb의 각도를 측정하는 등의 화상의 왜곡에 대한 비교 연구를 통해 3 spot DR 척추 전장 촬영 방법의 정확한 정보를 제공하는 것이다. 팬텀은 $H(40cm){\times}V(116cm){\times}D(2.3cm)$ 크기로 납판이 삽입 된 격자형 아크릴로 만들었다. 제작 모형을 사용하여 각 장비에 각각 3회, OFD를 변경하여 총 9회 촬영하였고 납 격자의 가로, 세로 길이와 비율을 측정하였다. 또한 모형에서 임의의 지점을 지정하여 Cobb 각도를 측정하였다. 가로 세로 비율은 CR은 0.98~1.01, scan DR은 0.96~0.97, 3 spot DR은 0.99~1.01로 측정되었다. Cobb 각도는 각각 $52.5{\sim}53.3^{\circ}$, $52.1{\sim}54.3^{\circ}$, $52.8{\sim}53.2^{\circ}$로 측정되었다. 실험 결과에 의해 평면 모형을 이용한 본 연구에서 척추 전장 촬영을 위한 3 spot DR 촬영 방식의 영상은 왜곡이 없는 정확한 방법이다.

북한 산림황폐지의 질감특성을 고려한 분할영상 기반 토지피복분류 (Segment-based land Cover Classification using Texture Information in Degraded Forest land of North Korea)

  • 김은숙;이승호;조현국
    • 대한원격탐사학회지
    • /
    • 제26권5호
    • /
    • pp.477-487
    • /
    • 2010
  • 북한의 산림은 1970년대부터 산지개간과 땔나무 채취, 벌목 등에 의해 대규모로 황폐화되었으며, 이러한 산림황폐지는 경제적, 환경적, 재해발생 측면에서 반드시 복구되어야 한다. 본 연구의 목적은 산림황폐지가 대규모로 발견되고 있는 북한 혜산 지역에 대해 산림복구사업 (A/R CDM 사업)을 계획할 수 있는 잠재적 대상지를 추출하기 위한 목적으로, 입목지와 산림황폐지(무립목지, 개간산지, 산간나지)를 보다 정확하게 분류하지 위한 고해상도 영상 기반의 영상분류기법을 개발하고자 한다. 북한의 산림황폐지 유형은 분광특성뿐 아니라 질감특성에 따라 구분될 수 있다. 따라서 본 연구에서는 2.5m SPOT Pan-Sharpened 영상을 이용해 분할영상을 제작하고 이 과정에서 생성된 질감(texture) 정보를 산림피복 분류 시 분광정보와 함께 활용했다. 분할영상의 제작 시 Scale factor 40/Shape Factor 0.3을 적용하였을 떼 각 산림피복 항목을 분리할 수 있는 적절한 규모의 분할조각이 생성되었다. 또한 산림 피복을 가장 잘 분류해내는 최적밴드를 선정한 결과 기존의 분광밴드 1/2/3 에 질감밴드인 GLCM_dissimilarity (밴드2), GLCM homogeneity (밴드2), GLCM_standard deviation (밴드3)를 추가 하였을 때 산림황폐지 유형간 분리도가 가장 커지는 것으로 나타났다. 질감특성을 이용한 분할영상기반 분류결과기법에 따른 분류결과(80.4%)는 분광정보만을 이용하는 방법의 분류결과(70.3%) 보다 정확도가 높았으며, 특히 입목지와 무립목지의 분리에 있어서 약 23~25%의 정확도 향상 효과를 보였다. 결론적으로 본 연구에서는 직접 현지조사를 하기 어려운 북한지역에 대해 고해상도 위성영상이 효과적인 산림피복분류의 근거를 제공했으며 영상의 분류 시 질감특성을 함께 활용하는 것이 상세한 산림피복 분류에 있어서 정확도 향상에 기여를 할 수 있다는 것을 확인할 수 있었다.

고해상도 위성영상에서의 동종센서 스테레오 모델과 이종센서 스테레오 모델의 비교 (Comparison of Single-Sensor Stereo Model and Dual-Sensor Stereo Model with High-Resolution Satellite Imagery)

  • 정재훈
    • 대한원격탐사학회지
    • /
    • 제31권5호
    • /
    • pp.421-432
    • /
    • 2015
  • 동일 센서 내의 스테레오 취득 원리에 기반하여 얻어진 동종센서 스테레오와 서로 다른 센서에서 얻어진 영상간에 임의로 결합된 이종센서 스테레오는 기하 특성과 스테레오 모델 정확도 측면에서 많은 차이를 보이게 된다. 이 논문에서는 고해상도 위성영상에서의 얻어진 동종센서 스테레오 모델과 이종센서 스테레오 모델을 비교한다. 실험을 위해 동일 지역을 촬영한 SPOT-5 스테레오와 KOMPSAT-2 스테레오 영상을 활용하여 총 2쌍의 동종센서 스테레오와 4쌍의 이종센서 스테레오 영상을 이용하였다. 동종센서 스테레오 모델의 경우 모두 안정적인 스테레오 기하를 형성한 반면, 이종센서 스테레오 모델의 경우 2조합은 비교적 안정적인 기하를 다른 2조합은 매우 불안정한 기하를 형성하였다. 그리고 불안정한 기하를 형성한 이종센서 스테레오의 경우 3차원 위치 정확도가 크게 감소하였다. 안정적인 스테레오 기하를 형성하는 이종센서 스테레오의 경우에도 동종센서 스테레오와는 차이점이 있었다. 전반적으로 수직 정확도 측면에서는 동종센서 스테레오 모델이 더 높은 정확도를 보인 반면, 수평 정확도 측면에서는 이종센서 스테레오 모델이 더 높은 정확도를 보여주었다. 논문에서는 두 가지 스테레오 모델이 가지는 기하 특성과 3차원 모델 정확도의 차이를 잘 드러내며, 고해상도 스테레오 영상 특히 이종위성 스테레오 자료를 효과적으로 활용하는데 있어 고려되어야 할 중요한 분석 결과들을 제시한다.

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

위성영상과 삼각점조서를 이용한 비접근지역의 영상지도작성 가능성 분석 (Possibility study of Image Mapping using Triangulation Summaries in Inaccessible Area)

  • 이준혁;이승현;이영진
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.133-138
    • /
    • 2006
  • Currently high resolution satellite imagery has been used in lots of fields of terrain analysis, ocean development, change detection, cartography, classification, environmental monitoring, earth resource observation, meteorological observation as well as military The accuracy of the 3-D modeling of SPOT-5 stereopair images using these ground control points is about 5m in planimetric distance error and about 2m in height error. This study demonstrates the available ground control points for North Korea, of which accuracy is as good as to generate the digital map at the scale of 1:25,000.

  • PDF