• Title/Summary/Keyword: SPEC-78

Search Result 10, Processing Time 0.027 seconds

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Development of the Bias-Cut Dress Pattern Making Method by Applying Fabric Draping Ratio

  • Park, Chan-Ho;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.4
    • /
    • pp.594-603
    • /
    • 2012
  • This study aimed to investigate a bias pattern making method with geometrical approach. The bias-cut dress has soft silhouette of drape in the garment. However, the bias cut dress has problem of satisfying the intended garment size spec. This problem occurs from various sources. The main reason is that the bias-cut fabric tends to stretch on longitudinal direction and to shrink horizontal direction when it was hung on the body. The goal of this study was to develop a bias-cut dress pattern making method satisfying the intended garment size spec. The researchers developed the geometrical method of measuring dimensional change by calculating the compensation ratio of the fabric in true bias direction. The compensation ratio was calculated by applying draping ratio of the fabric. Three types of fabrics were used in the experiment. The warp and weft crossing angle of fabric was ranged from $78^{\circ}$ to $82^{\circ}$. The fabrics stretched longitudinally 6.9~9.9% and shrank horizontally 7.2~11.0%. The compensation ratio of the bias-cut pattern for sample dress was calculated for each fabric type. Two types of experimental bias-cut dress patterns were developed for each fabric. One pattern was made with applying full compensation ratio and the other one made with applying partial ratio of the fabric. Experimental dresses were made with these patterns. The results of the evaluation showed that the bias-cut dress pattern applying the partial compensation ratio was more appropriate than the pattern applying the full compensation ratio.

Effect of optimal sodium stearoyl-2-lactylate supplementation on growth performance and blood and carcass characteristics in Hanwoo steers during the early fattening period

  • Lee, Shin Ja;Lee, Sang Suk;Kim, Eun Tae;Jeong, Jin Suk;Lee, Ji Hoon;Jeong, Joon;Park, Joong Kook;Park, Beom Young;Jeong, Ha Yeon;Ki, Kwang Seok;Kim, Chang Hyun;Lee, Sung Sill
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.9
    • /
    • pp.1442-1448
    • /
    • 2018
  • Objective: This study was conducted to evaluate the effect of different levels of total digestible nutrients (TDN) and sodium stearoyl-2-lactylate (SSL) supplementation on growth performance and blood and carcass characteristics in Hanwoo steers during the early fattening period. Methods: Sixty Hanwoo steers (average body weight, $333{\pm}36.4kg$) were randomly allotted to 3 treatments, with twenty steers per treatment, and ten steers per pen with a size of $80m^2$. Dietary treatments were as follows: CON, basal diet; treatment (TRT) 0.5, 0.5% down-spec of TDN with 0.1% SSL; TRT 1.0, 1.0% down-spec of TDN with 0.1% SSL. Results: The results demonstrated that average daily gain and feed efficiency increased with TRT 0.5 (0.85 kg and 11.68) vs CON (0.82 kg and 11.27) or TRT 1.0 (0.78 kg and 10.74), indicating that 0.1% SSL supplementation in the feed of early fattening steers may result in a saving of 0.5% TDN. No significant differences were observed amongst all treatments (p>0.05) for blood metabolite concentration and blood corpuscle values, which were all within the normally accepted range for healthy steers. Conclusion: Our study suggests that a TDN 0.5% down spec with 0.1% SSL supplemented feed may be effective and profitable for the early fattening period of Hanwoo steers without causing adverse effects.

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

Performance Comparison of Implementation Technologies for Image Quality Enhancement Operations on Android Platforms (Android 플랫폼에서 구현 기술에 따른 화질 개선 연산 성능 비교)

  • Lee, Ju-Ho;Lee, Goo-Yeon;Jeong, Choong-Kyo
    • Journal of Digital Contents Society
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • As mobiles devices with high-spec camera built in are used widely, the visual quality enhancement of the high-resolution images turns out to be one of the key capabilities of the mobile devices. Due to the limited computational resources of the mobile devices and the size of the high-resolution images, we should choose an image processing algorithm not too complex and use an efficient implementation technology. One of the simple and widely used image quality enhancement algorithms is contrast stretching. Java libraries running on a virtual machine, JNI (Java Native Interface) based native C/C++, and NEONTM SIMD (Single Instruction Multiple Data) are common implementation technologies in the case of Android smartphones. Using these three implementation technologies, we have implemented two image contrast stretching algorithms - linear and equalized, and compared the computation times. The native C/C++ and the NEONTM SIMD outperformed the native C/C++ implementation by 56-78 and 50-76 time faster respectively.

A comparison with Result of Normalized image to Different Template image on Statistical Parametric Mapping of ADHD children patients (과잉행동장애 어린이의 SPM(Statistical Parametric Mapping)분석에서 서로 다른 Template image로 규격화된 SPEC 영상의 결과 비교)

  • Shin, Dong-Ho;Park, Soung-Ock;Kwon, Soo-Il;Joh, Chol-Woo;Yoon, Seok-Nam
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.71-78
    • /
    • 2003
  • We studied 64 ADHD children patients group($4{\sim}15\;ys$, mean age : $8{\pm}2.6\;ys$. M/F:52/12) and 12 normal group($6{\sim}7\;ys$, mean age : $9.4{\pm}3.4\;ys$, M/F:8/4) of the brain has been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In increase of blood flow(P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

  • PDF

A Study on Field and Laboratory Test Methods to Obtain Non-linear Deformation Characteristics of Soft Rocks (퇴적연암의 비선형특성 조사.시험기법에 관한 연구)

  • 김유성
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.63-78
    • /
    • 1996
  • Various type of in-situ and laboratary tests were performed in order to evaluate the stiffness of sedimentary soft rock. In triaxial compression tests of sedimentary soft rocks, axial strains from the axial displacement of the loading piston or specimen cap conventionally were considerably larger than those measured. tocally on the lateral surfaces of specimen, due to the bedding errors at the top and bottom ends of a specimen. A local deformation transducer was used to measure axial strains free from the bedding error ranging from 0.001% to about 1%. In ultra-sonic wave tests, the elastic modulus of unconfined spec imens was smaller than that of confined specimens, due probably to microfracks. Young's modulus Ed from ultra-sonic wave tests and those at small local strains from triaxial tests were similar, both of which agreed very well with Young's modulus Er from field shear wave velocities. Young'a modulus from the field behaviour was virtually similar to that obtained by reducing Er based on the strain level-dependency of stiffness evaluated by the triaxial tests.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Effects of Supplemented PROSOL® as an Emulsifier on Growth Performance and Carcass Characteristics in Hanwoo Steers of Final Fattening Period (수용성 지방유화제 첨가가 비육후기 한우거세우의 발육과 도체성적에 미치는 영향)

  • Jeong, Joon;Hwang, Jeong-Mi;Seong, Nak-Il;Kim, Jeong-Bae;Hwang, Il-Ki;Kim, Yong-Chul
    • Journal of Animal Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.395-406
    • /
    • 2009
  • Fifty four Hanwoo steers in final fattening period were assigned to 3 groups control, top dressed $PROSOL^{(R)}$ as an emulsifier (TP) and DSP group (experimental diet made to down spec of nutrients with $PROSOL^{(R)}$, which is sodium stearoyl-2-lactylate), based on the body weight (647.96${\pm}$41.31 kg) and months of age (27.3${\pm}$0.8 mo), and the experiment was conducted to establish the reasonable fattening method of Hanwoo steers for 91 days. Average daily body gains during trial were 0.94, 0.84 and 0.98 kg in control, TP and DSP, respectively (P=0.011). DDMI/ADG of TP group tend to lightly improving compared to control and DSP group (P=0.692). There was no effect of supplementation of the $PROSOL^{(R)}$ in concentrates on growth rate, feed efficiency and shrinkage in Hanwoo steers during the short final fattening period. MQI from TP and DSP was not different based on the rib-eye area and carcass weight in carcass than that from control. Back fat thickness tended to be thicker than control (P>0.05). Marbling score, texture and maturity for TP and DSP was abundantly to increase compared to control (P<0.003). There was significantly increment in supplemented $PROSOL^{(R)}$ (P<0.0001). The meat quality grade of control, TP and DSP were 2.94, 3.78 and 4.50, respectively. Related to this result, the auction price (carcass/kg) were gained significantly (P<0.003) from control (17,560), TP (18,586) and DSP (19,266 won) so which the monetary return was the highest in DSP and the differences was recognized between TP and DSP. Percentage over 1st grade appeared in control, TP and DSP were 55.4, 88.9 and 100.0%, respectively. These results supported the hypothesis that supplementation of emulsifier improve the marbling score and the carcass quality grade by increased digestibilities of the feed fat in Hanwoo steers in fattening period.