• Title/Summary/Keyword: SNR gain

Search Result 263, Processing Time 0.028 seconds

Design and Implementation of Depolarized FOG based on Digital Signal Processing (All DSP 기반의 비편광 FOG 설계 및 제작)

  • Yoon, Yeong-Gyoo;Kim, Jae-Hyung;Lee, Sang-Hyuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.8
    • /
    • pp.1776-1782
    • /
    • 2010
  • The interferometric fiber optic gyroscopes (FOGs) are well known as sensors of rotation, which are based on Sagnac effect, and have been under development for a number of years to meet a wide range of performance requirements. This paper describes the development of open-loop FOG and digital signal processing techniques implemented on FPGA. Our primary goal was to obtain intermediate accuracy (pointing grade) with a good bias stability (0.22deg) and scale factor stability, extremely low angle random walk (0.07deg) and significant cost savings by using a single mode fiber. A secondary goal is to design all digital FOG signal processing algorithms with which the SNR at the digital demodulator output is enhanced substantially due to processing gain. The Cascaded integrator bomb(CIC) type of decimation filter only requires adders and shift registers, low cost processors which has low computing power still can used in this all digital FOG processor.

Multiple Node Flip Fast-SSC Decoding Algorithm for Polar Codes Based on Node Reliability

  • Rui, Guo;Pei, Yang;Na, Ying;Lixin, Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.658-675
    • /
    • 2022
  • This paper presents a fast-simplified successive cancellation (SC) flipping (Fast-SSC-Flip) decoding algorithm for polar code. Firstly, by researching the probability distribution of the number of error bits in a node caused by channel noise in simplified-SC (SSC) decoder, a measurement criterion of node reliability is proposed. Under the guidance of the criterion, the most unreliable nodes are firstly located, then the unreliable bits are selected for flipping, so as to realize Fast-SSC-Flip decoding algorithm based on node reliability (NR-Fast-SSC-Flip). Secondly, we extended the proposed NR-Fast-SSC-Flip to multiple node (NR-Fast-SSC-Flip-ω) by considering dynamic update to measure node reliability, where ω is the order of flip-nodes set. The extended algorithm can correct the error bits in multiple nodes, and get good performance at medium and high signal-to-noise (SNR) region. Simulation results show that the proposed NR-Fast-SSC-Flip decoder can obtain 0.27dB and 0.17dB gains, respectively, compared with the traditional Fast-SSC-Flip [14] and the newly proposed two-bit-flipping Fast-SSC (Fast-SSC-2Flip-E2) [18] under the same conditions. Compared with the newly proposed partitioned Fast-SSC-Flip (PA-Fast-SSC-Flip) (s=4) [18], the proposed NR-Fast-SSC-Flip-ω (ω=2) decoder can obtain about 0.21dB gain, and the FER performance exceeds the cyclic-redundancy-check (CRC) aided SC-list (CRC-SCL) decoder (L=4).

The Clinical Usefulness Evaluation of Normal Saline Injection in Coronary Artery Computed Tomography Angiography(Coronary CTA) (관상동맥 전산화단층촬영 조영검사에서 생리식염수 투여를 통한 임상 유용성 평가)

  • Jung, Kang-Kyo;Lee, Mi-Hwa;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.307-313
    • /
    • 2014
  • The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about $4.8{\pm}0.3bpm$ (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less $6.0{\pm}1.0mSv$ (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.