An Experimental Study on the Ventilation velocity of the Variation of Burning rate in Tunnel Fires - Heptane pool fire case (터널 화재시 배연속도가 연소율변화에 미치는 실험적 연구 - Heptane 풀화재 경우)

  • Ryou, Hong-Sun;Yang, Seung-Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.109-117
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the ventilation velocity of the variation of burning rate in tunnel fires. The heptane square pool fire with heat release rate ranging from 3.71~15.6 kW were used. The burning rate of fuel was obtained by measuring mass using load cell and temperature distributions were measured by K-type theomocouples in order to investigate smoke movement. The ventilation velocity in the tested tunnel was controlled by inverter of the wind tunnel. In heptane pool fire case, the increase in ventilation velocity incresed the burning rate due to the direct supply of oxygen to the fire plume. For the same dimensionless velocity($\bar{V}$), burning rate increased as the size of pool fire decreased.

  • PDF

Factors Related Smoking Cessation Attempts among Teenage Smokers (청소년 흡연자의 금연시도 관련 요인)

  • Park, Hye-rin;Wang, Yeon-ju;Kim, Kyoung-Beom;Kim, Bomgyeol;Kwon, Ohwi;Noh, Jin-won
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.7
    • /
    • pp.118-126
    • /
    • 2020
  • The purpose of the study is to analyze the relationship between the warning picture on a cigarette pack and non-smoking attempt, which is expected to contribute to the negative perception of smoking as a research subject about smoking adolescents. An online survey data of the Youth Health Behavior in 2018 has been used, and 3,722 adolescents who are currently smokers were selected for the study. For the measurement of variables, demographic sociology, health-related, and smoking-related factors have been revised, and multivariate binomial logistic regression analysis has been performed. The perception rate of cigarette warning pictures among adolescents who smoke currently is 84.7%, and among them, the attempt rate to quit smoking is 72.8%. As a result of the multivariate binomial logistic regression analysis, there is a meaningful relationship between adolescent smokers' attempts to quit smoking and whether they perceived cigarette pack warning pictures, and school grade year, academic performance, stress perception, and ease of purchasing cigarettes have been also expressed as meaningful variables. To be based on the result, it is necessary to manufacture to design a cigarette pack warning picture that can be easily recognized by smoking adolescents in the future.

A study of Stability of Emulsion Fuel (에멀젼 연료의 안정성에 대한 연구)

  • Kim, Moon-Chan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1330-1343
    • /
    • 2020
  • In this study, emulsion fuel which contained water of 10 ~ 20% was prepared mixed with water and MDO(Marine Diesel Oil) which largely used in near sea. Diffusion stability of emulsion fuel was measured. Diffusion stability was measured at 30℃, 45℃, and 60℃ for 10 days respectively. The stability of the emulsion fuel was stabilized in the order of MDO-10 > MDO-13 > MDO-16 > MDO-20 and it means that the stability of the emulsion fuel was found to be stable in the order of low water content. Meanwhile, an engine dynamo-meter was used to test whether the manufactured emulsion fuel was actually available in the engine. The emulsified MDO emulsion fuel could be used as fuel for ships. For samples with more than 16% water added emulsion fuel, smoke was reduced by more than 50% in the load area of more than 50%, and nitrogen oxides were reduced by 20%.

Fire test procedures for flammability of bulkhead, ceiling and deck finish materials (선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법)

  • Kim, S.Y.;Kim, D.S.;Ahn, B.H.;Kwark, J.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.117-119
    • /
    • 2008
  • It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead, ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper, we investigated the positive expected by fire test procedures for flammability of bulkhead, ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.

  • PDF

The Study on the Effect of Passenger Coach temperature When Aircurtains Installed At Electrical Rolling Stock At Entrance Door (전동차 출입문에 에어커튼 설치시 객실 온도 변화 연구)

  • Ahn Jong-Kon;Kim Chul-Ho;Park Duk-Sin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.489-496
    • /
    • 2004
  • The effect of airconditioning and heating system when aircurtains installed in subway electrical rolling stock at entrance door. It blocks cold/hot air of outside. It is good for health with its blocking effect against dusts exhaust fumes, odor bugs and smoke from outside. It always maintains clean and pleasant atmosphere inside. It helps you to have health with its ever-equal temperature distribution at inside. It saves lots of maintenance cost for heating/cooling (about 86$\%$) since it cuts the loss of hot air under heating as well as of cold air under air-conditionin. Customers can feel pleasant go in and out (better than before) with the door. It is an indispensable product for the employers to cut the cost. It makes customers feel pleasant near doors, since it isnt influenced by temperature difference of cold/hot air when the door opens/closes. In electrical rolling stock passenger temperature is a lot different from that the door opens/closes. One of the main aims is to create an acceptable thermal environment without draught problem. Temperature, gradients when aircurtains installed in subway electrical rolling stock at entrance door have been studied. And the temperature measured at 0.1, 0.5, 1.3, 1.7m above the floor. It has been found that temperature, with large fluctuations caused more draught influence.

  • PDF

Automobile Engine Information Display Device Using CAN Communication (캔 통신을 이용한 자동차 엔진 정보 표시장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.203-210
    • /
    • 2019
  • Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.

Recognition of Fire Levels based on Fuzzy Inference System using by FCM (Fuzzy Clustering 기반의 화재 상황 인식 모델)

  • Song, Jae-Won;An, Tae-Ki;Kim, Moon-Hyun;Hong, You-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.125-132
    • /
    • 2011
  • Fire monitoring system detects a fire based on the values of various sensors, such as smoke, CO, temperature, or change of temperature. It detects a fire by comparing sensed values with predefined threshold values for each sensor. However, to prevent a fire it is required to predict a situation which has a possibility of fire occurrence. In this work, we propose a fire recognition system using a fuzzy inference method. The rule base is constructed as a combination of fuzzy variables derived from various sensed values. In addition, in order to solve generalization and formalization problems of rule base construction from expert knowledge, we analyze features of fire patterns. The constructed rule base results in an improvement of the recognition accuracy. A fire possibility is predicted as one of 3 levels(normal, caution, danger). The training data of each level is converted to fuzzy rules by FCM(fuzzy C-means clustering) and those rules are used in the inference engine. The performance of the proposed approach is evaluated by using forest fire data from the UCI repository.

Assessment on the Flame Retardancy for Polyethylene/Montmorillonite Nanocomposite (Polyethylene/Montmorillonite Nanocomposite의 난연성 평가)

  • Song, Young-Ho;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.72-76
    • /
    • 2006
  • Polymer/clay nanocomposites have generated considerable interests in the past decade because adding just tiny amount of clay to the polymer matrix could produce a dramatic enhancement in physical, thermal and mechanical properties. Smectite clays, such as montmorillonite (MMT), are of great industrial value because of their high aspect ratio, plate morphology, intercalative capacity, natural abundance and low cost. In this study, PE/MMT nanocomposites were directly prepared by melt intercalating PE and the modified clay. The nanostructure was verified by X-ray diffraction (XRD) and transmission electron microscopy (TEM), and their flame retardant properties were measured and discussed by limiting oxygen index (LOI), char yield and smoke mass concentration. And their thermal stabilities were measured by differential thermogravimetric (DTG) and thermogravimetric analysis (TGA). The PE/MMT nanocomposites proved more effective the conventional composites in reinforcement. Two functions in the thermal stability of the PE/MMT nanocomposite, one is the barrier effect to improve the thermal stability, and another is catalysis, leading to a decrease of the thermal stability. The flammability was greatly decreased due to the formation of the clay-enriched protective char during the combustion.

A Study on Characteristics of Roof 'Jucsim' Structure Combustion Real Scale Fire Test on Wooden Structure Heritage Building (목조 건축 문화재 적심부 실물화재 실험을 통한 연소 특성 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.95-102
    • /
    • 2010
  • The combustion characteristics of roof 'Jucsim' structure was analysed using real scale fire test on wooden structure heritage building. the fire test model was made to consider roof timberling internal structure for a Sunglemun. Structure of test body layed lime, soil, 'Jucsin' and ceiling board excepting roof tile to find heat propagation process by setting thermocouples. The first test to find fire growth and heat propagation process in the part of ceiling. The second test organized to find the efficiency of fire proof paint between ceiling board and inside of Jucsim structure. The third test try to get the performance level of fire proof fabric with the same manner. The result showed from the test proof the heavy smoke exposure with limited effect of fire proof paint however, reliable fire resistance effect showed in case of fire proof fabric.

An Experimental Study on the Comparison of Operating Temperatures in Thermal Detector due to Tunnel Fire (터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구)

  • Roh, Hyeong-Ki;Park, Kwang-Young;Im, Seok-Been
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were and are being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical factors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tunnel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable to measure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor by performing fire simulations under the same condition as a real fire test. From the results, it has been found that the temperature sensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire simulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the currents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishing activities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directions of the fires correctly.