Drying Performance Simulation for the Basic Design of a Heat Pump Dryer (열펌프 건조기의 기본 설계를 위한 건조 성능 해석)

  • Lee, Kong-Roon;Kim, Ook-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.860-867
    • /
    • 2007
  • Heat pump drying has a great potential for energy saving due to its high energy efficiency in comparison with conventional air drying. In the present study, the performance simulation for the basic design of a heat pump dryer has been carried out. The simulation includes one-stage heat pump cycle, simple drying process using the drying efficiency. As an example, the heat pump cycle with Refrigerant 134a has been investigated. For the operating conditions such as the average temperature of the condenser, the heat rate released in the condenser, the flow rate of drying air, and drying efficiency, the simulation has been carried out to figure out the performance of the dryer. The parameters considered in the design of the dryer are COP, MER, SMER, the rate of dehumidification, the temperature and humidity of drying air and those parameters are compared for different conditions after carrying out the simulation.

Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer (순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석)

  • Lee, Kong-Hoon;Kim, Oak-Joong;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.

Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers (전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교)

  • Yang, Won Suk;Kim, Young Il;Park, Seung Tae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

Energy Performance Analysis of Electric Heater and Heat Pump Food Dryers (전기히터식 및 히트펌프식 식품 건조기의 에너지 성능 비교)

  • Yu, Young Woo;Kim, Young Il;Park, Seungtae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, energy performance of two types of food dryers which are electric heater and heat pump is studied experimentally. With drying chamber temperatures controlled at 45, 50 and $55^{\circ}C$, sliced radish is dried from an initial mass of 90 to final 7 kg. Moisture content, drying time, total power consumption, MER (moisture extraction rate, kg/h) and SMER (specific moisture extraction rate, kg/kWh) are measured and analyzed. As the drying chamber temperature is increased, drying time is shortened but energy efficiency is reduced for both types. For an electric heater dryer, the effect of chamber temperature on drying time is significant but less significant on energy efficiency. For a heat pump dryer, the dependence of chamber temperature on drying time is weak but strong on energy efficiency. Temperature levels have little effect on electric heater dryer performance but strong effect on heat pump dryer which operates on a vapor compression refrigeration cycle. The energy performance of the heat pump dryer is superior with an average SMER of 2.175 kg/kWh which is 2.22 times greater than that of the electric heater dryer with SMER of 1.224 kg/kWh.

A Study on the Performance of Home Clothes Dryer using Thermoelectric Module (열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구)

  • Lee, Min-Jae;Gong, Sang-Un;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

Investigation of Experimental Results Using the Drying Model for a Heat Pump Dryer (열펌프 건조 해석 모델을 이용한 측정 결과의 분석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Kim, Jong-Ryul;Lee, Sang-Ryoul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2268-2273
    • /
    • 2008
  • The drying model has been used to obtain the fundamental information required to design the heat pump dryer with the simple thermodynamic model. In the model, the input conditions are crucial to obtain the acceptable results. The model includes one-stage heat pump cycle, simple drying process using the drying efficiency. The drying efficiency is defined with the conditions of inlet and outlet in the dryer. The experiment has been carried out in the pilot dryer with one-stage heat pump cycle. Refrigerant 134a is used in the heat pump cycle. In the dryer, some of drying air flows through the heat pump system and the rest of air bypasses the heat pump system and circulates through the drying chamber. Some operating conditions from the pilot dryer are used as input conditions of the model and the results are compared with experimental results for the validation.

  • PDF

An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a (HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구)

  • Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.3-11
    • /
    • 1997
  • In conventional heat and vent dryer, both sensible and latent heat could not be recovered from the exhaust air, but this problem could be solved by introducing a heat pump to a conventional dryer, having a connection with cooling, dehumidifying and heating of heat pump. In this work, HFC134a as a substitute refrigerant of CFC12 adopted in heat pump and a batch type is also introduced. The variables affected on the system performance are holding temperature of a drying chamber, bypass air ratio, degree of superheat and refrigerant flowrate, etc. The moisture contents were decreased curvilinearly in the range of $86{\sim}75%$ on the wet basis. Under the constant drying temperature, the face velocity plays an important role to the drying performance. The COPs are increased in accordance with the air velocity, on the other hand the SMERs are gradually decreased.

  • PDF