• Title/Summary/Keyword: SMD Sauter

Search Result 195, Processing Time 0.023 seconds

A Study on Droplet Distribution of Bio Diesel Fuels Using Immersion Sampling Method (액침법에 의한 바이오디젤유의 액적분포에 관한 연구)

  • Kim, M.S.;Doh, H.C.;Koh, D.K.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.5-10
    • /
    • 2006
  • The purpose of this study is to measure the droplet distribution and Sauter mean diameter(SMD) of biodiesel fuel, using the immersion sampling method. This method involves using an optical microscope and a CCD camera, to take an image of the droplets. These images are then measured by using a 'Sigma Scan' processing program. The results of the above experiment are summarized as followed ; (1) There can be as much as a 10% error rate when measuring the diameter of these droplets, using the image processing method and the naked eye. (2) The result of droplet size distribution test, TVO(transesterified vegetable oil) big size droplet distribution were increased at ambient pressure $6kg/cm^2$. (3) When ambient pressure increased $6kg/cm^2$ above, SMD variation of TVO and UVO(used vegetable oil) 30 are small. (4) On Rosin-Rammler analysis, droplets size distribution of UVO(used vegetable oil) 30 uniform more than TVO 20 on ambient pressure $1kg/cm^2$.

  • PDF

A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System (전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구)

  • Jang, S.H.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

Effects of Ethanol Mixing Ratio on Spray Characteristics of Triplet Impinging Injector (에탄올 혼합비에 따른 3중 충돌형 인젝터의 분무특성)

  • Lee, In-Chul;Kim, Jong-Hyun;Koo, Ja-Ye
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2007
  • Spray characteristics of a unlike triplet injector were investigated experimentally. Spray images and SMD of droplet were measured to evaluate the spray characteristics injected by liquid/gas combinations. G-L-G(Gas-Liquid-Gas), L-G-L(Liquid-Gas-Liquid) type of injector were used by changing the gas and liquid feed lines. The SMD graph shows that the droplet sizes decrease in the out of radial direction at a fixed gas Reynolds number. The SMD value of decreasing tendency shows that the more ethyl alcohol ratio increase, the more SMD value decrease.

  • PDF

Review on the Gas Turbine Combustor Sizing Methodologies using Fuel Atomization and Evaporation Characteristics (연료의 미립화 및 증발 특성 데이터를 이용한 가스터빈 연소기 사이징 기법 고찰)

  • Kim, D.;Jin, Y.I.;Hwang, K.Y.;Min, S.K.
    • Journal of ILASS-Korea
    • /
    • v.19 no.3
    • /
    • pp.101-108
    • /
    • 2014
  • The current paper reviews the main characteristics and the operating principles of major fuel atomizers used for gas turbine combustors, including various empirical SMD equations for each atomizers. We have summarized various methodologies for evaluation of the combustion efficiency and for combustor sizing from the selected SMD data. It is found that the combustor sizing as well as the combustion efficiency are totally dependent upon the SMD calculation results, which means that special cares should be taken in choosing the SMD empirical equations.

Experimental Study of Droplet Characteristics Related to Electrospray Mode (정전분무모드에 관한 액적특성의 실험적 연구)

  • Kim, Ji Yeop;Lee, Doe Hyun;Cho, Ju Hyung;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.26-35
    • /
    • 2022
  • Electrospray is a method of atomizing fluid using high voltage supply and capable of generating continuous flow and coherent size of droplets. Electrical system and properties of fluids has enabled electrospray to have various spray modes. However, its studies have been confined only in Cone jet, which is more stable and easier to manipulate droplets' size than other spraying modes. Therefore, it is necessary to investigate and compare other spraying modes based on experimental parameters and physical properties of fluids. This research paper identified nine different spray modes. It was found out that Sauter Mean Diameter (SMD) is proportional to flow rate of fluids and maximum difference among spray modes was 1.7 times. On the other hand, SMD standard deviation had low variations on specific flow rates of fluids. Pulsed jet mode recorded the largest SMD standard deviation, while Spindle recorded the lowest.

Intermittent Atomization Characteristics of Multi-Hole and Single-Hole Diesel Nozzle

  • Lee, Jeekuen;Kang, Shin-Jae;Park, Byungjoon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1693-1701
    • /
    • 2002
  • The intermittent spray characteristics of a multi-hole and a single-hole diesel nozzle were experimentally investigated. The hole number of the multi-hole nozzle was 5, and the hole diameter of the 5-hole and the single-hole nozzle was the same as d$\_$n/=0.32 ㎜ with the constant hole length to diameter ratio(l$\_$n//d$\_$n/=2.81). The droplet diameters of the spray, including the time-resolved droplet diameter, SMD (Sauter mean diameter) and AMD (arithmetic mean diameter) , injected intermittently from the two nozzles into the still ambient were measured by using a 2-D PDPA (phase Doppler particle analyzer). Through the time-resolved evolutions of the droplet diameter, it was found that the structure of the multi-hole and the single-hole nozzle spray consisted of the three main parts : (a) the leading edge affected by surrounding air. and composed of small droplets; (b) the central part surrounded by the leading edge and mixing flow region and scarcely affected by the resistance of air, (c) the trailing edge formed by the passage of the central part. The SMD decreases gradually with the increase in the radial distance, and the constant value is obtained at the outer region of the radial distance (normalized by hole diameter) of 7-8 and 6 for the 5-hole and single-hole nozzle, respectively. The SMD along the centerline of the spray decrease shapely with the increase in the axial distance after showing the maximum value near the nozzle tip. The SMD remains the constant value near the axial distance(normalized by hole diameter) of 150 and 180 for the 5-hole and the single-hole nozzle, respectively.

Assessment of Prediction Ability of Atomization and Droplet Breakup Models on Diesel Spray Dynamic (디젤분무에서 미립화 및 액적분열모델의 예측능력평가)

  • Kim, J.I.;No, S.Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.2
    • /
    • pp.35-42
    • /
    • 2000
  • A number of atomization and droplet breakup models have been developed and used to predict the diesel spray characteristics. Of the many atomization and droplet breakup models based on the breakup mechanism due to aerodynamic liquid and gas interaction, four models classified as mathematical models, such as TAB, modified TAB, DDB, WB and one of the hybrid model based on WB and TAB models were selected for the assessment of prediction ability of diesel spray dynamics. The assessment of these models by using KIVA-II code was performed by comparing with the experimental data of spray tip penetration and sauter mean diameter(SMD) from the literature. It is found that the prediction of spray tip penetration and SMD by the hybrid model was only influenced by the initial parcel number. All the atomization and droplet breakup models considered here was strongly dependent on the grid resolution. Therefore it is important to check the grid resolution to get an acceptable results in selecting the models. At low injection pressure, modified TAB model could only give the good agreement with experimental data of spray tip penetration and both of modified TAB and DDB models were recommendable for the prediction of SMD. At high injection pressure, hybrid model could only give the good agreement with the experimental data of spray tip penetration and the prediction of all of the selected models did not match the experimental data. Spray tip penetration was increased with the increase the $B_1$ and the increase of $B_1$ did not affected the prediction of SMD.

  • PDF

Optimum Design of Dual Orifice Fuel Nozzle (이중 오리피스 연료 노즐 최적설계)

  • Lim, O-Kaung;Choi, Eun-Ho;Kim, Sung-Sub
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.407-416
    • /
    • 2007
  • Fuel spray nozzle has a critical effect on combustion characteristics. Mass flow rate and SMD(sauter mean diameter) were selected as design variables by using the experiment data of various types of duplex fuel nozzles for the swirl atomizers. The sensitivity of each design variable on the mass flow rate and SMD was analyzed and the uniformity of mass flow rate was investigated through the shape optimization of duel-orifice-type swirl atomizers. The design variables that have a little effect on the optimum design were excluded using the DOE(design of experiments) method, which enabled the optimization of sensitive design variables on mass flow rate and limit tolerance. The SMD of the research spray nozzle that was used in this study was found to be most similar to that of the calculation results using the Jasuja's SMD relationship. This study showed the specific characteristics of duel orifice type swirl atomizers and the optimization of these kinds of nozzle. This study provided the optimization design of mass flow rate and its allowable tolerance.

A Effect of Fuel Properties on Spray Structure for Dual Orifice Fuel Injector (연료의 물성치 변화가 이중 오리피스 연료 노즐의 분무 구조에 미치는 영향에 관한 연구)

  • Lee, Dong-Hun;Choi, Seong-Man;Park, Jeong-Bae
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.179-188
    • /
    • 2003
  • The spray characteristics of dual orifice injector were investigated under two different fuels through measurement of SMD, number density and volume flux by using PDPA system. In this experiment, we found out that the droplet size and spray structure are strongly depend on fuel density and viscosity.

  • PDF

An experimental study on spray pattern and droplet size distribution of diesel spray (디젤 분무의 분무 형태와 입경 분포에 관한 실험적 연구)

  • 지요한;이종화;김응서
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.102-108
    • /
    • 1992
  • To clarify the structure of a diesel spray, a transient non-evaporating diesel spray injected under different ambient pressure and different injection pressure was studied. Spray tip penet- ration and spray angle were measured by taking the high speed shadowgraph of spray and Sauter mean Diameter(SMD) was also measured by light scattering technique at different positions along the spray axis and at different time from the start of injection. The effects of the operating parameters on the spray shape and SMD were investigated. By increasing the injection pressure, the spray tip penetration and the spray angle increased and the change of the ambient pressure also resulted in the considerable change in the shape of the spray. The analysis of SMD measurement showed that the atomization is a process that continues in sp- ace and time. As the injection pressure increases SMD decreases rapidly and with the increa- se of the ambient pressure the atomization process ends faster than the lower ambient press- ure and at lower pressure the atomization process continues to much farther downstream and far afterward.

  • PDF