• Title/Summary/Keyword: SMC1A

Search Result 168, Processing Time 0.028 seconds

Effect of Selenium Sources on Meat Quality of Hanwoo Steers (셀레늄 급여원에 따른 한우 채끝육의 육질 특성)

  • 박범영;조수현;성필남;하경희;이성훈;황인호;김동훈;김완영;이종문;안종남
    • Journal of Animal Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.603-610
    • /
    • 2006
  • This study was conducted to investigate the feeding effect of selenium provided by different sources on the physico-chemical properties of M. longissimus thoracis. Twenty Hanwoo steers(20~24 months, approximately 613kg) were assigned to 4 different feeding groups of each five, depending on the sources of selenium such as inorganic selenium(sodium selenite), organic selenium(Yeast, USA Sel-Plex), Se-SMC(Se-spent mushroom compost) and the control(no selenium). The selenium level in feed was 0.9 ppm for all groups except the control. Animals were fed with different feeding treatments for 12 weeks and slaughtered at National Livestock Research Institute. The inorganic selenium group had the highest cooking loss(CL. %) and followed by the Se-SMC group and organic selenium group. No significant differences in chemical composition, WB-shear forces, water-holding capacity(WHC) and sensory properties were found among the groups(P>0.05). There were 40% frequencies of grade A in the inorganic selenium group and followed by the organic selenium group(20%). Se-SMC group had 80% of frequencies for grade 1+ and followed by the inorganic selenium group(40%), whereas the organic selenium group and the control group had the 20% frequencies for grade 1+. From the results of this study showed that the selenium sources did not affect chemical composition, WHC and tenderness of Hanwoo steers. However, the inorganic selenium group had the highest cooking loss(%) and lowest pH when compared to the other groups.

The SMC Model: Identification of Artistically Gifted Students from Low Income Families (사회적 배려대상 예술영재 판별모형 개발)

  • Lee, Seon-Young
    • Journal of Gifted/Talented Education
    • /
    • v.22 no.1
    • /
    • pp.87-115
    • /
    • 2012
  • This study is about the development of an identification model for artistically gifted students from low income and/or multi-cultural families. Given that parental support at early ages is crucial for talent development, students from low income families are often dismissed in recognizing their artistic giftedness. Based on a comprehensive literature review and consultations with experts in art, the SMC model was developed to identify disadvantaged gifted students in the areas of music, visual arts, and ballet. The model consists of three steps of identification, such as review of documents and teacher recommendations, evaluations of artistic giftedness, and a summative evaluation, and involves multiple criteria for identifying giftedness in both domain general and domain specific arts. SMC is promising in discovering many unrecognized disadvantaged children of artistic potential, thereby using various quantitative and qualitative measures. Yet, issues of validity and reliability of SMC need to be substantiated by subsequent theoretical and empirical studies.

A Study on the Electrical Characteristics of Low Temperature Polycrystalline Thin Film Transistor(TFT) using Silicide Mediated Crystallization(SMC) (금속유도 결정화를 이용한 저온 다결정 실리콘 TFT 특성에 관한 연구)

  • 김강석;남영민;손송호;정영균;주상민;박원규;김동환
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.129-129
    • /
    • 2003
  • 최근에 능동 영역 액정 표시 소자(Active Matrix Liquid Crystal Display, AMLCD)에서 고해상도와 빠른 응답속도를 요구하게 되면서부터 다결정 실리콘(poly-Si) 박막 트랜지스터(Thin Film Transistor, TFT)가 쓰이게 되었다. 그리고 일반적으로 디스플레이의 기판을 상대적으로 저가의 유리를 사용하기 때문에 저온 공정이 필수적이다. 따라서 새로운 저온 결정화 방법과 부가적으로 최근 디스플레이 개발 동향 중 하나인 대화면에 적용 가능한 공정인 금속유도 결정화 (Silicide Mediated Crystallization, SMC)가 연구되고 있다. 이 소자는 top-gated coplanar구조로 설계되었다. (그림 1)(100) 실리콘 웨이퍼위에 3000$\AA$의 열산화막을 올리고, LPCVD로 55$0^{\circ}C$에서 비정질 실리콘(a-Si:H) 박막을 550$\AA$ 증착 시켰다. 그리고 시편은 SMC 방법으로 결정화 시켜 TEM(Transmission Electron Microscopy)으로 SMC 다결정 실리콘을 분석하였다. 그 위에 TFT의 게이트 산화막을 열산화막 만큼 우수한 TEOS(Tetraethoxysilane)소스로 사용하여 실리콘 산화막을 1000$\AA$ 형성하였고 게이트는 3000$\AA$ 두께로 몰리브덴을 스퍼터링을 통하여 형성하였다. 이 다결정 실리콘은 3$\times$10^15 cm^-2의 보론(B)을 도핑시켰다. 채널, 소스, 드래인을 정의하기 위해 플라즈마 식각이 이루어 졌으며, 실리콘 산화막과 실리콘 질화막으로 passivation하고, 알루미늄으로 전극을 형성하였다 그리고 마지막에 TFT의 출력특성과 전이특성을 측정함으로써 threshold voltage, the subthreshold slope 와 the field effect mobility를 계산하였다.

  • PDF

Maximum Control Force for Sliding Mode Controller with Saturation Problem (포화현상을 고려한 슬라이딩 모드제어기의 최대제어력 산정)

  • 이상현;민경원;김홍진;이영철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Sliding mode control (SMC), which is one of active control algorithms showing remarkable control performance, requires the excessive control force for control of seismically excited civil structures. Therefore, controller saturation should be considered in design of SMC. In this study, a method for determining the maximum control force is developed in terms of the fraction of the lateral restoring force using a design response spectrum. Numerical analyses of MDOF structures with one or multiple control devices verify the effectiveness of the proposed method for the control of seismically excited civil structures with saturation problem.

Clinical and molecular characteristics of Korean children with Cornelia de Lange syndrome

  • Dayun Kang;Hwa Young Kim;Jong-Hee Chae;Jung Min Ko
    • Journal of Genetic Medicine
    • /
    • v.19 no.2
    • /
    • pp.85-93
    • /
    • 2022
  • Purpose: Cornelia de Lange syndrome (CdLS) is a rare genetically heterogeneous disorder caused by genetic variants of the cohesin complex. However, the diverse genetic etiologies and their phenotypic correlations in Korean patients with CdLS are still largely unknown. Hence, this study aimed to clarify the clinical characteristics and genetic background of Korean patients with CdLS. Materials and Methods: The medical records of 15 unrelated patients (3 males and 12 females) genetically confirmed to have CdLS were retrospectively reviewed. All individuals were diagnosed with CdLS using target gene analysis, whole-exome sequencing, and/or chromosomal microarray analysis. The clinical score (CS) was calculated to assess disease severity. Results: The median age at diagnosis was 1.7 (range, 0.0-11.8) years, and median follow-up duration was 3.8 (range, 0.4-11.7) years. Eight (53.3%) patients showed classic phenotypes of CdLS, two (13.3%) showed non-classic phenotypes, and five (33.3%) had other phenotypes sharing limited signs of CdLS. Fifteen causative variants were identified: NIPBL in five (33.3%, including 3 males), SMC1A in three (20.0%), SMC3 in three (20.0%), and HDAC8 in four (26.7%) patients. The CS was significantly higher in the NIPBL group than in the non-NIPBL group (14.2±1.3 vs. 8.7±2.9, P<0.001). Conclusion: We identified the clinical and genetic heterogeneity of CdLS in Korean patients. Patients with variants of NIPBL had a more distinctive phenotype than those carrying variants of other cohesin complex genes (SMC1A, SMC3, and HDAC8). However, further studies are warranted to understand the pathogenesis of CdLS as a cohesinopathy and its genotype-phenotype correlations.

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.

Selective Musculocutaneous Neurotomy for Spastic Elbow

  • Shin, Dong-Keun;Jung, Young-Jin;Hong, Joo-Chul;Kim, Min-Su;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.236-239
    • /
    • 2010
  • Objective : The purpose of this study was to investigate the effectiveness and outcome of selective musculocutaneous neurotomy (SMcN) for spastic elbow. Methods : We retrospectively reviewed the medical records of 14 patients with spasticity of their elbows. The patients were selected using clinical and analytical scales, as well as nerve block tests, for assessment. Their mean age was 37.29 years (range, 19-63 years). SMcN was performed for these patients, and the mean follow-up period was 30.71 months (range, 19-54 months). Results : The modified Ashworth scale (MAS) scores recorded before and after the SMcN showed that the patients' mean preoperative MAS score of $3.28{\pm}0.12$ was improved to $1.71{\pm}0.12$, $1.78{\pm}0.18$, $1.92{\pm}0.16$ and $1.78{\pm}0.18$ at postoperative 3, 6, 12 months and last follow-up, respectively. On the basis of a visual analogue score ranging from 0-100, the patients' mean degree of satisfaction score was $65.00{\pm}16.52$ (range, 30-90). Conclusion : We believe that SMcN can be a good and effective treatment modality with low morbidity in appropriately selected patients who have localized spastic elbow with good antagonist muscles and without joint contracture.

Improved Sliding Mode Controller for Shunt Active Power Filter

  • Sahara, Attia;Kessal, Abdelhalim;Rahmani, Lazhar;Gaubert, Jean-Paul
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.662-669
    • /
    • 2016
  • In this work, nonlinear control of a three-phase shunt active power filter (SAPF) has been studied and compared to classical control based on proportional integral regulator. The control strategy is based on the direct current method using sliding mode control (SMC), where the aim is to regulate the average voltage across the dc bus of the inverter. Details are given for the control algorithm; the controller is comprised of a current loop which utilizes a hysteresis controller to generate the gating signals for the switching devices, and a nonlinear controller based on SMC law which is different from classical laws based on error between reference and measured output voltage of the inverter. Sliding surface applied in this work contains the whole of state variables, in order to ensure full control of the system behavior in the presence of disturbances that affect the supply source, the load parameters or the reference value. The designed controller offers advantage that it can gives the improvement of dynamic and static performances in cases of large disturbances. A comparison of the effects of PI control and SMC on the APF response in steady stat, under line variations, load variations, and different component variations is performed.

Apsidal motions of 90 eccentric binary systems in the Small Magellanic Cloud

  • Hong, Kyeongsoo;Lee, Jae Woo;Kim, Seung-Lee;Koo, Jae-Rim;Lee, Chung-Uk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.42.1-42.1
    • /
    • 2016
  • We examined thousands of light curves of stars brighter than 18.0 mag in I band and less than mean magnitude error of 0.1 mag in V band from the OGLE-III eclipsing binary catalogue, and found 90 new binary systems exhibiting apsidal motion. In this study, the samples of apsidal motion stars in the SMC were increased by 250 percent than previously known. In order to determine the period of the apsidal motion for the binaries, we analysed in detail both light curves and eclipse timings using the MACHO and OGLE photometric database obtained for about 20 yrs. For the eclipse timing diagrams of the systems, new times of minimum light were derived from the full light curve combined at intervals of one yr from the survey data. The binaries presented in this paper have apsidal motion periods in the range of 12-918 yrs. An additional short-term oscillation was detected in five systems (OGLE-SMC-ECL-1634, 1947, 3035, 4946, and 5382), which most likely arise from the existence of a third body orbiting each eclipsing binary. All of the selected systems can be used for the statistical study of the interior structure of the stars in the SMC through their apsidal motions due to the homogeneous data and consistent analysis methods.

  • PDF

Nutrition Intervention in a Gastric Cancer Patient With Gastrectomy for 12 Months: A Case Report

  • So Young Youn;Bo Eun Kim;Eun Mee Kim
    • Clinical Nutrition Research
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Gastrectomy is the most effective method of treating gastric cancer, but it is commonly associated with weight loss, nutritional deficiencies, and the increased risk of malnutrition due to post-surgery complications, including gastric stasis, dumping syndrome, malabsorption, and maldigestion. Malnutrition is a risk factor for postoperative complications and poor prognosis. To prevent it and guarantee a quick recovery after surgery, continuous and individualized nutrition intervention should be performed both before surgery and postoperatively. The Department of Dietetics at Samsung Medical Center (SMC) performed nutritional status assessment before gastrectomy, initial nutritional assessment within 24 hours of admission, description of therapeutic diet after surgery, nutrition counselling before discharge, and nutritional status assessment and individual nutrition counselling after 1, 3, 6, and 12 months from surgery. This is a case report of a patient who underwent gastrectomy as well as intensive nutrition intervention in SMC.