• 제목/요약/키워드: SLS(scanning laser source) technique

검색결과 3건 처리시간 0.016초

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

Fabrication of Microcantilever Ultrasound Sensor and Its Application to the Scanning Laser Source Technique

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.459-466
    • /
    • 2005
  • The scanning laser source (SLS) technique has been proposed recently as an effective way to investigate small surface-breaking defects, By monitoring the amplitude and frequency changes of the ultrasound generated as the SLS scans over a defect, the SLS technique has provided enhanced signal-to-noise performance compared to the traditional pitch-catch or pulse-echo ultrasonic methods, An extension of the SLS approach to map defects in microdevices is proposed by bringing both the generator and the receiver to the near-field scattering region of the defects, To facilitate near-field ultrasound measurement, silicon microcantilever probes are fabricated using microfabrication technique and their acoustical characteristics are investigated, Then, both the laser-generated ultrasonic source and the microcantilever probe are used to monitor near-field scattering by a surface-breaking defect.

배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술 (Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline)

  • 최상우;이준현;조윤호
    • 비파괴검사학회지
    • /
    • 제25권2호
    • /
    • pp.95-102
    • /
    • 2005
  • 원자력 발전소의 많은 배관부는 고온, 고압환경에서 적용되고 있어 환경적 및 기계적 요인에 의하여 부식결함이 빈번히 발생하고 있다. 이와 같은 부식 결함은 초음파 기법 등에 의하여 평가되어야 하고, 본 연구에서는 주사형 레이저 유도 초음파(SLS) 기법을 도입하여 배관부 부식결함의 영상화 기법을 적용하였다. 본 기법은 표면이 거칠거나 배관재와 같은 곡면의 표면에서 적용할 수 있는 장점이 있다. 한편 기존의 주사형 초음파 기법은 초음파 센서와 검사대상체 사이의 초음파 전달 매개체를 확보하기 위하여 시험편이 수침되거나 워터젯을 이용하였으나 주사형 레이저 초음파 기법은 광학적 기법을 이용하여 초음파를 발생시키므로 비접촉 방법에 의한 주사 이미지 획득이 가능하다. 따라서 본 주사형 레이저 초음파 기법은 복잡한 구조물의 검사, 비접촉 원격 및 고화질의 결함 이미지 탐상이 가능하다. 본 연구에서는 배관 결함의 검출능 향상을 위하여 결함 영상 획득에 있어서 다양한 조건의 레이저 유도 초음파 발생 기법을 적용하였고, 배관에 존재하는 응력부식 균열의 결함 영상을 얻게 되었다.