• 제목/요약/키워드: SLA surface

검색결과 103건 처리시간 0.028초

Bone healing dynamics associated with 3 implants with different surfaces: histologic and histomorphometric analyses in dogs

  • Lee, Jungwon;Yoo, Jung Min;Amara, Heithem Ben;Lee, Yong-Moo;Lim, Young-Jun;Kim, Haeyoung;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.25-38
    • /
    • 2019
  • Purpose: This study evaluated differences in bone healing and remodeling among 3 implants with different surfaces: sandblasting and large-grit acid etching (SLA; IS-III $Active^{(R)}$), SLA with hydroxyapatite nanocoating (IS-III $Bioactive^{(R)}$), and SLA stored in sodium chloride solution ($SLActive^{(R)}$). Methods: The mandibular second, third, and fourth premolars of 9 dogs were extracted. After 4 weeks, 9 dogs with edentulous alveolar ridges underwent surgical placement of 3 implants bilaterally and were allowed to heal for 2, 4, or 12 weeks. Histologic and histomorphometric analyses were performed on 54 stained slides based on the following parameters: vertical marginal bone loss at the buccal and lingual aspects of the implant (b-MBL and l-MBL, respectively), mineralized bone-to-implant contact (mBIC), osteoid-to-implant contact (OIC), total bone-to-implant contact (tBIC), mineralized bone area fraction occupied (mBAFO), osteoid area fraction occupied (OAFO), and total bone area fraction occupied (tBAFO) in the threads of the region of interest. Two-way analysis of variance (3 types of implant $surface{\times}3$ healing time periods) and additional analyses for simple effects were performed. Results: Statistically significant differences were observed across the implant surfaces for OIC, mBIC, tBIC, OAFO, and tBAFO. Statistically significant differences were observed over time for l-MBL, mBIC, tBIC, mBAFO, and tBAFO. In addition, an interaction effect between the implant surface and the healing time period was observed for mBIC, tBIC, and mBAFO. Conclusions: Our results suggest that implant surface wettability facilitates bone healing dynamics, which could be attributed to the improvement of early osseointegration. In addition, osteoblasts might become more activated with the use of HA-coated surface implants than with hydrophobic surface implants in the remodeling phase.

Effect of the Laser Beam Size on the Cure Properties of a Photopolymer in Stereolithography

  • Sim, Jae-Hyung;Lee, Eun-Dok;Kweon, Hyeog-Jun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권4호
    • /
    • pp.50-55
    • /
    • 2007
  • Stereolithography (SLA) is a technique using a laser beam to cure a photopolymer liquid resin with three-dimensional computer-aided design (CAD) data, The accuracy of the prototype, the build time, and the cured properties of the resins are controlled by the SLA process parameters such as the size of the laser beam, scan velocity, hatch spacing, and layer thickness, In particular, the size of the laser beam is the most important parameter in SLA, This study investigated the curing properties of photopolymers as a function of the laser beam size, The cure width and depth were measured either on a single cure line or at a single cure layer for various hatch spacings and laser beam sizes, The cure depth ranged from 0.23 to 0.34 mm and was directly proportional to the beam radius, whereas the cure width ranged from 0.42 to 1.07 mm and was inversely proportional to the beam radius, The resulting surface roughness ranged from 1.12 to $2.23{\mu}m$ for a ratio of hatch spacing to beam radius in the range 0.5-2.0 at a beam radius of 0.17 mm and a scan velocity of 125 mm/sec.

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • 제47권3호
    • /
    • pp.182-192
    • /
    • 2017
  • Purpose: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.

미세유체시스템 제작을 위한 3D 프린팅 방식 및 소재 별 표면특성 비교 (Comparison of Surface Characteristics According to 3D Printing Methods and Materials for the Fabrication of Microfluidic Systems)

  • 배서준;임도진
    • Korean Chemical Engineering Research
    • /
    • 제57권5호
    • /
    • pp.706-713
    • /
    • 2019
  • 본 연구에서는 미세유체 시스템 제작에 적합한 3D 프린팅 방식 및 소재 별 표면특성 분석을 통해 각 응용 사례에 적합한 프린터 및 소재 선정에 가이드라인을 줄 수 있는 기초 연구를 수행하였다. 가장 보편적으로 사용되는 적층 방식과 해상도가 상대적으로 높은 광경화 방식에 대해 프린팅 방식과 소재에 따른 표면 특성을 살펴보았다. 적층 방식의 프린트물은 소재에 무관하게 후처리 전에는 친수성 특성을 보이나 아세톤 증기에 의한 후처리 후에는 소수성 특성을 보임을 확인할 수 있었다. SEM을 이용한 표면 조도 관찰을 통해 이러한 접촉각의 변화가 후처리에 의한 표면의 결 구조의 제거에 기인한 것임을 확인하였다. 광경화식 프린트물은 적층식 대비 친수성의 특성을 보였으나 소수성 코팅을 이용해 표면 개질이 가능함을 실험적으로 확인하였다. 두 프린팅 방식 중 투명한 재질이 요구되는 경우, 적층 방식은 투명한 시편을 만드는 것이 불가능함을 확인하였으며 광경화 방식의 경우 충분한 투명도가 확보됨을 확인하였다. 액적 접촉충전 현상에 기반한 디지털 전기천공 시스템의 electroporation chip을 광경화 방식으로 제작하였으며 성공적으로 전기천공을 시연함으로써 미세유체 시스템에 직접 적용이 가능함 또한 확인하였다.

유전자 알고리즘을 이용한 광조형장치의 작업변수 결정 (Determining Variables of Fabrication for Stereolithograpy)

  • 전근수;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.910-913
    • /
    • 2000
  • In this research we investigate geometric issues involved while using a particular rapid prototyping system, called Stereolithography(SLA). SLA create prototypes layer by layer, each layer being formed by scanning a laser beam across the x, y surface of a vat of liquid monomer mix. The performance of SLA is influenced by orientation and layer thickness of designed fabrication. The number of layer and the area needed support is influenced by the orientation and layer thickness of designed fabrication. The step influence and volume error is influenced by slice thickness. We minimize the support are, the number of layer and cusp height. These variables of fabrication is minimized using genetic algorithm. The time for genetic algorithm is as little as we can accept. So we calculate support area and cusp height simply.

  • PDF

트랙터 트랜스미션용 후진 아이들 기어의 3D 프린팅 특성 (3D Printing Characteristics of Reverse Idle Gears for Tractor Transmissions)

  • 김해지
    • 한국기계가공학회지
    • /
    • 제16권4호
    • /
    • pp.1-8
    • /
    • 2017
  • This paper concerns the possibility of 3D printing reverse idle gears for tractor transmission. For the purposes of this experiment, idle gears were manufactured using a SLA 3D printer, FDM 3D printer, and through machining. The accuracy of the idle gears produced in these three different ways were evaluated by the properties of their outer diameter, inner diameter, roundness, concentricity, parallelism, span, backlash, and gear grade. The tooth characteristics of the idle gears were evaluated by their profile, lead, and the pitch of the gears. The results of this experiment determined that the surface conditions created by the finishing process had a significant impact on the dimensional accuracy of the gears and the characteristics of their teeth.

쾌속 조형시스템의 제작 및 성능평가에 관한 연구 (A Study on the Manufacture and the Performance Evaluation of Stereolithography System)

  • 강원주;김준안;이석희;백인환
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.19-25
    • /
    • 1999
  • This paper addresses a development work of a SLA apparatus on laboratory basis. The SLA test machine is composed of optical, movement, curing and control subsystems. Optical part is performed by a He-Cd laser with mirror combination and mechanical movement is achieved by X-Y table. The developed system is evaluated by several test runs, and shows a good precision capability in forming a basic part. The technique used in this work can be extended to replace the high technology transfer cost of commercial RP machine.

  • PDF

GENE-EXPRESSION PROFILING OF TITANIUM-CELL INTERACTION

  • Kim, Chang-Su;Hwang, Jung-Won;Ryu, Jae-Jun;Shin, Sang-Wan;Sohn, Sung-Hwa;Kim, Ki-Nam;Kim, Meyoung-Kon
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.393-408
    • /
    • 2005
  • Statement of problem. In the process of bone formation, titanium (Ti) surface roughness is an important factor modulating osteoblastic function. Purpose. This study was carried out to determine the effect of different Ti surface on biologic responses of a human osteoblast-like cell line (MG63). Materials and methods. MG63 cells were cultured on S (smooth), SLA (sandblasted largegrit & acid etching), HA (hydroxyapatite) Ti. The morphology and attachment of the cells were examined by SEM. The cDNAs prepared from total RNAs of MG63 were hybridized to a human cDNA microarray (1,152 elements). Results. The appearances of the surfaces observed with SEM were different in the three types of dental substrates. The surface of SLA and HA were shown to be rougher than S. MG63 cells cultured on SLA and HA were cell-matrix interaction. In the expression of genes involved in osseointegration, upregulated genes were bone morphogenetic protein, Villin, Integrin, Insulin-like growth factors in different surfaces. Downregulated genes were fibroblast growth factor receptor 4, Bcl 2-related protein, collagen, CD4 in different surfaces. Conclusion. The attachment and expression of key osteogenic regulatory genes were enhanced by surface roughness of the dental materials.

The histometric analysis of osseointegration in hydroxyapatite surface dental implants by ion beam-assisted deposition

  • Kim, Min-Kyung;Choi, Jung-Yoo;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Sung-Tae;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제38권sup2호
    • /
    • pp.363-372
    • /
    • 2008
  • Purpose: This study compared the effects of coating implants with hydroxyapatite (HA) using an ion beam-assisted deposition (IBAD) method prepared with machined, anodized, sandblasted and large-grit acid etched (SLA) surfaces in minipigs, and verified the excellency of coating method with HA using IBAD. Material and Methods: 4 male Minipigs(Prestige World Genetics, Korea), 18 to 24 months old and weighing approximately 35 to 40 kg, were chosen. All premolars and first molars of the maxilla were carefully extracted on each side. The implants were placed on the right side after an 8 week healing period. The implant stability was assessed by resonance frequency analysis (RFA) at the time of placement. 40 implants were divided into 5 groups; machined, anodized, anodized plus IBAD, SLA, and SLA plus IBAD surface implants. 4 weeks after implantation on the right side, the same surface implants were placed on the left side. After 4 weeks of healing, the minipigs were sacrificed and the implants were analyzed by RFA, histology and histometric. Results: RFA showed a mean implant stability quotient (ISQ) of $75.625{\pm}5.021$, $76.125{\pm}3.739$ ISQ and $77.941{\pm}2.947$ at placement, after 4 weeks healing and after 8 weeks, respectively. Histological analysis of the implants demonstrated newly formed, compact, mature cortical bone with a nearby marrow spaces. HA coating was not separated from the HA coated implant surfaces using IBAD. In particular, the SLA implants coated with HA using IBAD showed better contact osteogenesis. Statistical and histometric analysis showed no significant differences in the bone to implant contact and bone density among 5 tested surfaces. Conclusion: We can conclude that rough surface implants coated with HA by IBAD are more biocompatible, and clinical, histological, and histometric analysis showed no differences when compared with the other established implant surfaces in normal bone.