• Title/Summary/Keyword: SLA method

Search Result 115, Processing Time 0.022 seconds

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

Response Time-based Web Service Availability Measurement Method (응답시간기반 웹 서비스 가용성 측정방안)

  • Park, Sang- Kun;Choi, Deok-Jai
    • The KIPS Transactions:PartC
    • /
    • v.10C no.1
    • /
    • pp.61-70
    • /
    • 2003
  • I-Business providers and customers have chosen the service availability as the most important technical parameter which should be included in their SLA to succeed in their business. This means that web Service availability management is crucial to the web-based service providers. Application availability is originally defined as a measure of the fraction of time during a defined period when the service provided is deemed to be better than user expectation of service performance. But, because most web service availability measurement tools simply monitor disconnected state, they do not satisfy user's expectation of extended availability concept. In this paper, We propose the web service availability measurement method which supports extended availability concept. It takes account of performance degradation of web service based on response time, and determines what is the cause of unavailability of the service. We developed a measurement tool, WebSerAvail.

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

cSNP Identification and Genotyping from C4B and BAT2 Assigned to the SLA Class III Region (돼지 SLA class III 영역 내 C4B 및 BAT2의 cSNP 동정 및 이를 이용한 유전자형 분석)

  • Kim, J.H.;Lim, H.T.;Seo, B.Y.;Lee, S.H.;Lee, J.B.;Yoo, C.K.;Jung, E.J.;Jeon, J.T.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.549-558
    • /
    • 2007
  • C4B and BAT2, assigned to the SLA class III region, were recently reported on relation with human diseases. The primers for RT-PCR and RACE-PCR for CDS analysis of these genes of pig were designed by aligning the CDSs of humans and mice from GenBank. After we amplified and sequenced with these primers and cDNAs, the full-length CDSs of pig were determined. The CDS lengths of C4B and BAT2 were shown as 5226 bp and 6501 bp. In addition, the identities of nucleotide sequences with human and mouse were 76% to 87%, and the identities of amino acids were 72% to 90%. After we carried out the alignment with determined CDSs in this study and pig genomic sequences from GenBank, the primers for cSNP detection in genome were designed in intron regions that flanked one or more exons. Then, we amplified and directly sequenced with genomic DNAs of six pig breeds. Four cSNPs from C4B and three 3 cSNPs from BAT2 were identified. In addition, amino acid substitution occurred in six cSNP positions except for C4248T of C4B. By the Multiplex-ARMS method, we genotyped seven cSNPs with DNA samples used for direct sequencing. We verified that this result was the same as that analyzed using direct sequencing. To demonstrate recrudescence, we performed both direct sequencing and Multiplex-ARMS on two randomly selected DNA samples. The genotype of each sample showed the same result from both methods. Therefore, seven cSNPs were identified from C4B and BAT2 and could be used as the basic data for haplotype analysis of SLA class III region. Moreover, the Multiplex-ARMS method should be powerful for genotyping of genes assigned to the whole SLA region for the xenograft study.

Comparison of Surface Characteristics According to 3D Printing Methods and Materials for the Fabrication of Microfluidic Systems (미세유체시스템 제작을 위한 3D 프린팅 방식 및 소재 별 표면특성 비교)

  • Bae, Seo Jun;Im, Do Jin
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.706-713
    • /
    • 2019
  • In this study, basic research was conducted to provide guidelines for selecting printers and materials suitable for each application case by analyzing 3D printing method and surface characteristics of materials suitable for microfluidic system. We have studied the surface characteristics according to the materials for the two typical printing methods: The most commonly used method of Fused Deposition Modeling (FDM) printing and the relatively high resolution method of Stereolithography (SLA) printing. The FDM prints exhibited hydrophilic properties before post - treatment, regardless of the material, but showed hydrophobic properties after post - treatment with acetone vapor. It was confirmed by the observation of surface roughness using SEM that the change of the contact angle was due to the removal of the surface structure by post-treatment. SLA prints exhibited hydrophilic properties compared to FDM prints, but they were experimentally confirmed to be capable of surface modification using hydrophobic coatings. It was confirmed that it is impossible to make a transparent specimen in the FDM method. However, sufficient transparency is secured in the case of the SLA method. It is also confirmed that the electroporation chip of the digital electroporation system based on the droplet contact charging phenomenon was fabricated by the SLA method and the direct application to the microfluidic system by demonstrating the electroporation successfully.

Study on the Measurement-Based Packet Loss Rates Assuring for End-to-End Delay-Constrained Traffic Flow (지연 제한 트래픽 흐름에 대한 측정 기반 패킷 손실률 보장에 관한 연구)

  • Kim, Taejoon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1030-1037
    • /
    • 2017
  • Traffic flows of real-time multimedia services such as Internet phone and IPTV are bounded on the end-to-end delay. Packets violating their delay limits will be dropped at a router because of not useful anymore. Service providers promise the quality of their providing services in terms of SLA(Service Level Agreement), and they, especially, have to guarantee the packet loss rates listed in the SLA. This paper is about a method to guarantee the required packet loss rate of each traffic flow keeping the high network resource utilization as well. In details, it assures the required loss rate by adjusting adaptively the timestamps of packets of the flow according to the difference between the required and measured loss rates in the lossy Weighted Fair Queuing(WFQ) scheduler. The proposed method is expected to be highly applicable because of assuring the packet loss rates regardless of the fluctuations of offered traffic load in terms of quality of services and statistical characteristics.

Dimensional Characteristics of Impeller Output Using 3D Printers (3D 프린터를 이용한 임펠러 출력물의 치수 특성)

  • Kong, Jeong-Ri;Kim, Hae-Ji
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.56-62
    • /
    • 2022
  • This study analyzed the output precision of 3D printing methods. The inner impeller of the centrifugal compressor was printed in as a sheet with 100% packing density using two methods: field deposition modelling and stereolithography. Dimensional differences between the initial CAD and printed models were evaluated using a 3D scanner. To investigate the dimensional characteristics of the 3D printed impeller, 3D dimension analysis and point dimension analysis were performed. The point dimension analysis was divided into 3D and 2D for comparative analysis.

Defect Diagnostics of Gas Turbine Engine Using Support Vector Machine and Artificial Neural Network (Support Vector Machine과 인공신경망을 이용한 가스터빈 엔진의 결함 진단에 관한 연구)

  • Park Jun-Cheol;Roh Tae-Seong;Choi Dong-Whan;Lee Chang-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.102-109
    • /
    • 2006
  • In this Paper, Support Vector Machine(SVM) and Artificial Neural Network(ANN) are used for developing the defect diagnostic algorithm of the aircraft turbo-shaft engine. The system that uses the ANN falls in a local minima when it learns many nonlinear data, and its classification accuracy ratio becomes low. To make up for this risk, the Separate Learning Algorithm(SLA) of ANN has been proposed by using SVM. This is the method that ANN learns selectively after discriminating the defect position by SVM, then more improved performance estimation can be obtained than using ANN only. The proposed SLA can make the higher classification accuracy by decreasing the nonlinearity of the massive data during the training procedure.

One-to-All and All-to-all Broadcasting Algorithms of Matrix Hypercube (매트릭스 하이퍼큐브의 일-대-다 방송과 다-대-다 방송 알고리즘)

  • Kim, Jongseok;Lee, Heongok
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.8
    • /
    • pp.825-834
    • /
    • 2018
  • Broadcasting is a basic data communication method for interconnection networks. There are two types of broadcasting. One-to-all broadcasting is to transmit a message from one node to all other nodes and all-to-all broadcasting is to transmit a message from all the nodes that have messages to other nodes. And by the using way of the transmission port per unit time, there are two schemes of broadcasting. Single port telecommunication(SLA) is to transmit messages from one node that contains the messages to one adjacent node only and all port telecommunication(MLA) is to transmit messages from one node to all adjacent nodes within a time of unit. Matrix hypercube is that an interconnection network has improved network cost than that of hypercube with the same number of nodes. In this paper, we analyze broadcasting scheme of matirx hypercube. First, we propose one-to-all and all-to-all broadcasting algorithms of matrix hypercube. And we prove that one-to-all broadcasting times are 2n+1 and $2{\lceil}{\frac{n}{2}}{\rceil}+1$ based on the SLA and MLA models, respectively. Also, we show all-to-all broadcasting time using SLA model is $5{\times}2^{\frac{n}{2}}-2$ when n=even, and is $5{\times}2^{\frac{n-1}{2}}+2$ when n=odd.

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.