• Title/Summary/Keyword: SIS

Search Result 389, Processing Time 0.025 seconds

Pressure Sensitive Adhesion Performances of SIS/SBS based UV-curable Pressure Sensitive Adhesives using Thiol-ene Reaction (Thiol-ene 반응을 이용한 UV경화형 SIS/SBS계 점착제의 점착물성)

  • Lim, Dong-Hyuk;Do, Hyun-Sung;Kim, Hyun-Joong;Yoon, Goan-Hee;Bang, Jung-Suk
    • Journal of Adhesion and Interface
    • /
    • v.6 no.3
    • /
    • pp.19-25
    • /
    • 2005
  • Synthetic rubber based pressure-sensitive adhesives (PSAs) usually containing SIS or SBS block copolymer, tackifier, plasticizer, and other additives are now widely used on various applications. As these PSAs are physically crosslinked and can be applied without the use of solvent, they are thermally processable and environmentally friendly. However these PSAs cannot be used in high temperature applications and in applications where solvent and chemical resistance properties are required. We developed the PSA adding UV curable system, such as thiol-ene system, to increase adhesion properties at elevated temperature. The adhesion properties such as probe tack, peel strength, shear adhesion failure temperature (SAFT) were evaluated. The probe tack test was conducted with varying probe materials and coating thickness of PSAs. Using the contact angle, the surface property of the cured PSAs was also observed.

  • PDF

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.

The design of 85GHz-115Ghz band SIS mixer for the observing cosmic radio waves (85GHz-115Ghz 대 우주전파 관측용 초전도체 믹서 설계)

  • 한석태;김효령;이창훈;박종애;정현수;김광동;김태성;박동철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.90-98
    • /
    • 1996
  • We have evaluated the theoretical conversion loss and noise temperature of mixer using the quantum mixer theory and the method to determine the embedding impedance of waveguide-type mixer mount. At fixed backshort position of the mixer, the calculated SSB mixer conversion loss and mixer noise temperature are 5 dB and 10K within frequency range form 85 GHz to 115 GHz, respectively. The SIS mixer has been developed by using through on the calculated rsutls to observe cosmic radio waves. SIS junction of mixer is Nb/Al-AlOx/Nb and it consists of four series array. Area of each of junction is about 2.5${\mu}m^{2}$. The average receiver noise temperature of manufactured receiver with this mixer is about 30 K(DSB). The receiver noise temperature is much lower than that of receiver with a mixer using mechanical tuning backshort.

  • PDF

Improvement of Bonding Performance for Biotissue using Marine Mussel Extract Adhesive (홍합 추출 접착액을 이용한 바이오 티슈의 접합능력 향상에 관한 연구)

  • Cho, B.;Stroshine, Richard
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.115-120
    • /
    • 2007
  • The adhesive performance of marine mussel extract was compared with that of the commercial medical adhesives for fastening biotissue (SIS) bandages. Joints bonded with mussel extract showed stronger strength than those bonded with other commercial adhesives. The bonding strength was much improved when the moisture in the Joint was reduced using superporous hydrogel regardless of curing time under humid condition ($37^{\circ}C$ and 91% relative humidity). Water inflow into the SIS joint seemed to degrade the performance of mussel extracts adhesive especially for the joints of short period of curing time. The strength of SIS joints coated with surgical sealant was well maintained after being exposed to water inflow.

Ship information system: overview and research trends

  • Liu, Sheng;Xing, Bowen;Li, Bing;Gu, Mingming
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.670-684
    • /
    • 2014
  • Ship Information Systems (SISs) have been one of the main research focuses in ship design and become a multidisciplinary area. With these growing research trends, it is important to consolidate the latest knowledge and information to keep up with the research needs. In this paper, the SIS and its different forms are introduced and discussed. The beginning of this paper discusses the history and evolution of SIS. The next part of this paper focuses on different fields and research areas such as networking technology, information fusion, information decision, message display, ship control in real-time SISs. A Semi-Physical Simulation Platform (SPSIM) designed for SIS research and its running effect through a new Fuzzy-PID fusion algorithm are introduced in this paper then. A brief literature survey and possible future direction concerning each topic is included.

A Method to Compensate a Luminance Distortion of a Time-multiplexing Spatially Interlaced Stereoscopic Three-dimensional Display

  • Park, Minyoung;Choi, Hee-Jin
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.436-442
    • /
    • 2018
  • In a spatially interlaced stereoscopic (SIS) three-dimensional (3D) display to be realized by providing the observer a part of left-eye/right-eye images, a loss of information can be perceived due to the un-shown part of each image. In order to resolve that problem, an improved SIS 3D display is proposed to deliver the images without loss of information to the observer using a time-multiplexing scheme. However, that time-multiplexing SIS also has a problem of luminance distortion when the desired luminance is not shown due to an insufficient response of the liquid crystal cell. In this paper, we propose a new method by optimizing the image data to show correct luminance with minimum distortion.

DYNAMICS OF AN IMPROVED SIS EPIDEMIC MODEL

  • Reza Memarbashi;Milad Tahavor
    • The Pure and Applied Mathematics
    • /
    • v.30 no.2
    • /
    • pp.203-220
    • /
    • 2023
  • A new modification of the SIS epidemic model incorporating the adaptive host behavior is proposed. Unlike the common situation in most epidemic models, this system has two disease-free equilibrium points, and we were able to prove that as the basic reproduction number approaches the threshold of 1, these two points merge and a Bogdanov-Takens bifurcation of codimension three occurs. The occurrence of this bifurcation is a sign of the complexity of the dynamics of the system near the value 1 of basic reproduction number. Both local and global stability of disease-free and endemic equilibrium point are studied.

Analysis of Rheological Properties for Styrene Copolymers (스티렌 공중합체의 유변학적 특성 해석)

  • 한민현
    • The Korean Journal of Rheology
    • /
    • v.4 no.1
    • /
    • pp.46-51
    • /
    • 1992
  • 본 연구에서는 열가소성고무를 중심으로 한 스티렌 공중합체의 유변학적 특성을 Couette 보정치를 사용하여 해석하였다. 실험재료로는 SBS(Styrene-Butadiene-Styrene), SEBS(Styrene-Ethylene/Buthylene-Styrene), SIS(Styrene-Isoprene-Styrene)을 사용하였고 탄성체의 성격을 비교하기 위하여SBS(Styrene-Butadiene Rubber)와 IR(Isoprene Rubber)를 사용하였다, 실험결과 Couette 보정치는 온도가 증가할수록 감소하였다. 또한 열가소성 고부 (SBS, SEBS, SIS)의 보정치는 거의 비슷한 값을 나타내었으며 고무(IR, SBR)의 보정치는 열가소성고무에서보다 다소 높은 값을 나타내었다. 충진제를 첨가하였을 경우 충진제의 양 이 증가할수록 Couette 보정치는 감소하였다.

  • PDF

정보보호 전문가(SIS) 자격 검정제도 발전 방안

  • Park, Soon-Tai;Park, Jun-Hyung;Noh, Bong-Nam
    • Review of KIISC
    • /
    • v.19 no.1
    • /
    • pp.40-58
    • /
    • 2009
  • 증가하는 인터넷 해킹사고와 전자정부의 확산 등으로 정보보호에 대한 필요성이 증대하고 있으며, 산업체 또는 정부에서 정보보호를 담당하는 인력의 수요가 필요하다. 본고에서는 정보보호 인력 양성의 방법으로 정보보호 관련 정규과정에 의한 방법이 아닌 정보보호 자격 검정에 의한 방안을 다룬다. 국외의 공인정보시스템보안전문가(CISSP), 공인정보시스템 감사사(CISA) 및 국내의 정보보호전문가(SIS) 등 국내외 3개의 정보보호 자격에 대한 비교연구를 통하여 정보보호전문가 자격제도의 발전 방안을 제시하고자 한다.