• Title/Summary/Keyword: SI technique

Search Result 1,432, Processing Time 0.026 seconds

Monitoring of Landslide in Kangwondo Area using 2-Pass DInSAR Technique (2-Pass DInSAR 기술을 활용한 강원도 지역 산사태 탐측)

  • Yoo, Su Hong;Sohn, Hong Gyoo;Jung, Jae Hoon;Choi, Si Kyong
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.2
    • /
    • pp.85-90
    • /
    • 2009
  • In recent days, climatic change cause abnormal weather all over the world and we have a great loss of life and property every year. In Korea, we suffer from landslide problem because large regions of Korea Peninsula are composed of mountain. In order to detect rapidly and to take follow-up measures of disaster, the remote sensing is being used actively as conventional field survey has many restrictions in accessibility because of more time and man power requirement. In additions interferometric SAR is one of the techniques that have our attention because it can provide many kinds of accurate surface information without restriction of atmospheric and ground conditions by using L-band. In this study, we aimed to monitor the displacement of mountain area in Kangwondo and this results will be used for detecting landslide. Also we build the web system for detecting and analyzing the landslide.

  • PDF

DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask (Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구)

  • Sohn, Hyonkee;Park, Jong-Sig;Jeong, Su-Jeong;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.16 no.3
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

Comparative antigen analysis of yrichomonus vaginulis by enzyme-linked immunoelectrotransfer blot technique (효소면역 전기영동 이적법을 이용한 질트리코모나스 항원의 비교 분석)

  • 민득영;임미혜
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.4
    • /
    • pp.323-328
    • /
    • 1992
  • Analysis of siR isolates of Trichemenes veginalis was carried out with sodium dodecyl sulfate- polyacrylamide gel electrophoresis (SDS-PAGE) and enzyme-linked immunoelectrotransfer blot (EITB). Trichloroacetic acid-treated antigens of the 6 isolates revealed 25 protein profiles ranging 12~170 kDa of molecular weight in SDS-PAGE. In EITB, the specific immunogenic bands were visualized at 51 kDa and 96 kDa when HY-1 antigen was probed with difFerent mice sera immunized with 6 isolates of T. vaginalis. The banding patterns with different sera showed isolate-to-isolate variability. In EITB, homologous antigen (HY-1) did not show any enhanced response in reacting to homologous antiserum(HY-1) when 6 isolates of T. vaginalis were probed with a single serum (HY-1). It is assumed that the different banding patterns of six isolates show isolate-to-isolate variability and immunogenic common bands in 41, 47, 74 and 9:k kDa on EITB may connote the important significance on immune response in T. vaginalis infection.

  • PDF

Nonparametic Kernel Regression model for Rating curve (수위-유량곡선을 위한 비매개 변수적 Kernel 회귀모형)

  • Moon, Young-Il;Cho, Sung-Jin;Chun, Si-Young
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1025-1033
    • /
    • 2003
  • In common with workers in hydrologic fields, scientists and engineers relate one variable to two or more other variables for purposes of predication, optimization, and control. Statistics methods have improved to establish such relationships. Regression, as it is called, is indeed the most commonly used statistics technique in hydrologic fields; relationship between the monitored variable stage and the corresponding discharges(rating curve). Regression methods expressed in the form of mathematical equations which has parameters, so called parametric methods. some times, the establishment of parameters is complicated and uncertain. Many non-parametric regression methods which have not parameters, have been proposed and studied. The most popular of these are kernel regression method. Kernel regression offer a way of estimation the regression function without the specification of a parametric model. This paper conducted comparisons of some bandwidth selection methods which are using the least squares and cross-validation.

A Study on Ion Extraction Characteristics of Ceramics by Cleaning Agents (보존처리용 세척제에 대한 토기의 이온용출 특성연구)

  • Park, Dae-Woo;Kang, Hyun-Mi;Nam, Byeong-Jik;Jang, Sung-Yoon;Ham, Chul-Hee
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.43-57
    • /
    • 2010
  • This study intends to provide quantitative data about the extraction characteristics of major elements of earthenware by executing soaking test of cleaning agents. It aims at providing basic data for the stability assessment when applying the cleaning agents for conserving earthenware. The data will be extracted from the analysis of co-relationship between the physical characteristics and the ion extraction characteristics. XRD analysis displayed that AT-1, AT-2 and AT-3 which did not generate mullite were fired at lower than 1,000 whereas AT-3 and AT-5 that included mullite were higher than 1,000. The degree of absorption was AT-4 > AT-2 > AT-1 > AT-3 > AT-5 in order and the correlation between the degree of absorption and firing temperature of earthenware displayed a positive correlation. Extraction amount of oxalic acid which was used for the removing iron oxide was AT-1 > AT-2 AT-4 > AT-3 > AT-5 in order. and the ion extraction data displayed that there is a positive correlation with absorption level. However AT-1 and AT-2 which were fired at lower temperature showed that there was no correlation between the ion extraction characteristics and absorption level. Ion extraction of citric acid produced little amount compared with the one of oxalic acid, yet it caused less damage to earthenware than oxalic acid when it applied. The result of ion extraction level in the absorption test displayed that Fe had higher level than in Si, Al from the test for both oxalic acid and citric acid. Based on the regression analysis of the data from the previous studies, the physical characteristics of the earthenware and ion extraction level, further studies will be conducted on the predicting technique on the extraction characteristics of major elements of earthenware samples for the conservation in future.

  • PDF

Evaluation of the Corrosion Resistance of Steel Coated with Zinc Using a Cr-free Coating Solution as a Function of Heat Treatment Time (Cr-free 코팅액에 의한 아연도금강판의 건조시간에 따른 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.67-74
    • /
    • 2010
  • Chromate conversion coating is a coating technique used to passivate aluminum, zinc, cadmium, copper, silver, magnesium, tin, and their alloys to slow corrosion. The process uses various toxic chromium compounds, which may include hexavalent chromium. The industry is developing less toxic alternatives in order to comply with substance restriction legislation, such as RoHS. One alternative is to develop a Cr-free coating solution. In this study, eco-friendly, Cr-free solutions (urethane solution S-700, organic/inorganic solution with Si LRO-317) were used. Test specimens were dried in a drying oven at $190^{\circ}C$ for 3, 5, 7, and 9 minutes. Corrosion resistance was evaluated using a salt spray test for 72 hours. The results show that the optimum corrosion resistance was achieved at $190^{\circ}C$ for five minutes for EGI and three or five minutes for HDGI, respectively. The adhesive properties of the two types of coating solutions were superior regardless of drying time.

Thermal Elasto-Plastic Deformation Analysis of Metal Matrix Composites Considering Residual Stress and Interface Bonding Strength (잔류응력과 계면접합강도를 고려한 금속복합재료의 열탄소성 변형 해석)

  • Kang, Chung-Gil;Seo, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.227-237
    • /
    • 1999
  • As the interface bonding phenomenon between the matrix and the reinforcements has a large effect on the mechanical properties of MMCs, a sugestion of the strength analysis technique considering the residual stress and the interface bonding phenomenon is very important for the design of pans and the estimation of fatigue behavior. In this paper the three dimensional finite element anaysis is performed during the elasto-plastic deformation of the particulate reinforced metal matrix composites. It was analyzed with the volume fractions in view of microscale. Bonding strength. interface separation and matrix void growth between the matrix and the reinforcements will be predicted on deformation under tensile loading. An interface seperation is estimated by the fracture criterion which is a critical value of generalized plastic work per unit volume. The shape of the reinforcement is assumed to be a perfect sphere. And the type of the reinforcement distribution is assumed as FCC array. The thermal residual stress in MMCs is induced by the heat treatment. It is included at the simulation as an initial residual stress. The element birth and death method of the ANSYS program is used for the estimation of the interface bonding strength, void generation and propagation. It is assumed that the fracture in the matrix region begin to occur under the external loading when the plastic work per unit volume is equal to the critical value. The fracture strain will be defined. The experimental data of the extruded $SiC_p$>/606l Al composites are compared with the theoretical results.

  • PDF

Control of Size and Morphology of Particles Using CO2 Laser in a Flame (화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어)

  • Lee, Donggeun;Lee, Seonjae;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

Analysis of Contact Singular Stresses with Relief Notch by Using Dynamic Photoelasticity(II) (동적 광탄성실험에 의한 응력이완 노치부근에서의 접촉특이응력 해석 (2))

  • Lee, Eok-Seop;Hwang, Si-Won;Nah, Gyeong-Chan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2097-2107
    • /
    • 1996
  • The dynamic photoelastic technique had been utilized to investigate the possibillity of relieving the large local singular stresses induced at the corner of a right- angle- indenter. The indenter compressed a semi-infinite body dynamically with an impact load applied on the top of the indenter. The effects of the geometric changes of the indenter in terms of the diameter (d) and the location (1) of the stress relieving notch on the behavior of the dynamic contact stresses were investigated. The influence of stress relieving notches positioned along the edge of the semi-infinite body on the dynamic contact stresses were also studied by changing the diameter (D) and the location (L) of the notch. A multi-speak-high speed camera with twelve sparks were used to take photographs of full field dynamic isochromatic fringe patterns. The contact singular stresses were found to be released significantly by the stress relief notches both along the indenter and the edge of the semi-infinite body. The optimal position and geometry of the stress relieving notches were obtained with the aid of limited experimental results.

Thoracoscopic Lung Biopsy for Diffuse Interstitial Lung Disease (미만성 간질성 폐질환에서 비디오 흉강경을 이용한 폐생검)

  • 심성보;연성모
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.741-746
    • /
    • 1996
  • Diffuse interstitial lung disease due to a wide variety of conditions are amenable to diagnosis by means of clinical evaluation, bronchoalveolar lavage, transbronchial biopsy and lung biopsy. The recently introduced technique of thoracoscopic wedge biopsy provides the potential advantages of greater selection of biopsy site and reduced postoperative chest pain compared with the standard open lung biopsy Video assisted thoracoscopic lung biopsy was performed in twenty patients for diagnosis of diffuse in- terstitial lung disease during the period from January 1993 to June 1994. The ages of the patients ranged from 18 to 69 years(mean 48.5 years), and the patients consisted of 10 males and 10 females. In all twenty, thoracoscpic lung biopsy samples were obtained; 9 from left lower lobe, 7 from right lower lobe, 2 from right upper lobe, 1 from left upper lobe, and 1 from right middle lobe. All patients were correctly diagnosed. The two common diseases were usual in erstitial pneumonia(UIP)(8120) and mil- liary tuberculo si s(4120) . Mean duration of the chest drainage was 3.2 days. There was no complication.

  • PDF