• Title/Summary/Keyword: SFI-bar$^{(R)}$

Search Result 3, Processing Time 0.016 seconds

Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

  • Ha, Seung-Ryong;Kim, Sung-Hun;Song, Seung-Il;Hong, Seong-Tae;Kim, Gy-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.254-258
    • /
    • 2012
  • Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar$^{(R)}$ is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar$^{(R)}$ was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar$^{(R)}$ system in a mandibular edentulous patient.

Implant-retained overdentures with pre-fabricated bar attachment system in edentulous patients (무치악 환자에서 기성 조립식 bar를 이용한 임플란트 피개의치 증례)

  • So, Na-Young;Hong, Young-Gi;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.41-48
    • /
    • 2016
  • Edentulous patients with severe alveolar bone resorption have trouble with using traditional complete denture. In order to overcome these problems, implant-retained overdenture was developed. SFI-bar$^{(R)}$ system can save time and cost compared to other existing bar systems which need complicated laboratory procedures because it can be adjusted directly in a patient's mouth. A 55-year-old male, who had experienced a fractured lower old implant-retained overdenture, wanted a durable and painless denture. The fractured Locator$^{(R)}$ attachments were removed and edentulous mandible was restored with SFI-bar$^{(R)}$. A 77-year-old female with a medical history of the Parkinson's disease and severely absorbed alveolar bone of mandible, wanted to wear a retentive mandibular denture without pain. After placing two implants in front of mental foramen, two adaptors were connected to two implants and a tube bar was connected to the adaptors. A female part fitted to the bar was attached to the new denture. These clinical reports describe two-implant-retained overdenture using the SFI-bar$^{(R)}$ system in mandibular edentulous patients. Since the patients were satisfied esthetically and functionally during 2 years' observation, we would like to report cases.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.