• 제목/요약/키워드: SFCL

검색결과 482건 처리시간 0.026초

3차권선이 추가된 직렬연결형 초전도한류기의 전류제한 및 회복 특성 향상 (Improvement of Current Limiting and Recovery Characteristics in Series Connection Type SFCL with Added Third Winding)

  • 고석철;한태희;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.62-68
    • /
    • 2014
  • The series connection type superconducting fault current limiter (SFCL) with added third winding, which was magnetically coupled in one iron core, was proposed. The proposed SFCL was expected to be more improved by just adding third winding into the conventional series connection type SFCL with two coils. To analyze the contribution of the third winding for the current limiting and the recovery characteristics of the SFCL, the short-circuit tests for the series connection type SFCL with the added third winding were performed together with the analysis on its electrical equivalent circuit. From the comparative analysis on the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising this SFCL, the improved current limiting and recovery characteristics of the series connection type SFCL using the third winding could be confirmed.

삼상 분리형 자속구속형 전류제한기의 동작 특성 분석 (Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL)

  • 두승규;두호익;박충렬;김민주;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

시뮬레이션을 통한 자기결합을 이용한 초전도 한류기의 전류제한 특성 분석 (An Analysis on Current Limiting characteristics of an SFCL using Magnetic Coupling between Two Coils through Computer Simulation)

  • 김진석;안재민;임성훈;문종필;김재철;김철환;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, the fault current limiting characteristics for the superconducting fault current limiter(SFCL) using magnetic coupling between two coils were investigated. The SFCL consists of a high-$T_c$ superconducting(HTSC) element and two coils. This SFCL has different characteristics that depend on the connection form, the winding direction and the inductance ratio of two coils. The impedance and the operational current of the SFCL can be adjusted higher or lower than the resistance and the critical current of HTSC element. Therefore, the SFCL can change the amplitude of the limited fault current. To confirm it, the HTSC element was modeled and the fault current limiting characteristics of the SFCL were analysed through computer simulation. It was obtained from the analysis that the connection form and the winding direction of two coils of the SFCL were the important design parameters.

190 kVA급 초전도한류소자의 특성 (Characteristics of a 190 kVA Superconducting Fault current Limiting Element)

  • 마용호;이주영;박권배;오일성;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

재폐로 동작에 따른 초전도 한류기의 회복성능 분석 (Analysis of the Recovery Behavior of SFCL According to Reclosing Operation)

  • 하경훈;조용선;김덕구;최효상
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1073-1077
    • /
    • 2011
  • The breaking capacity of circuit breakers could be no more increased in the electric power system. This is because the fault current increases due to continuous increases in electric power demand and facilities. To solve the problem, it is necessary to come up with an alternative. The superconducting fault current limiter (SFCL) has received an attention among various alternatives. The SFCL effectively reduce a fault current in cooperation with a power circuit breaker. A various types of the SFCL are suggested and a study on them have been progressed. As a result of it, the SFCL can be applyed to the electric power system in the near future. But, a study on recovery behaviors of the SFCL is not enough for applying to the electric power system. If the superconducting elements do not completely recover to the superconducting state after fault operation, it might be a breakdown of the superconducting elements due to heavy power burden and it gives an bad influence on the working of other electric devices. Additionally, the distribution power system has reclosing operation such as open-0.3sec-closed/open-3min-closed/open procedure. So we need to study more about improvement of the recovery behaviors of the SFCL. In this paper, we analyzed the recovery behaviors of a flux-coupling type SFCL according to reclosing operation when a single line-to-ground fault occurred and we compared recovery behaviors of the SFCL with and without a neutral line between secondary reactors and superconducting elements. Also, the flux-coupling type SFCL has advantageous for increases of capacity by controlling the variation in turn ratios between two reactors. Consequently, when the number of turns of the secondary reactors increased, the power burden of the superconducting elements was bigger due to the increase of impedances of the secondary reactors. To distribute the power burden, two superconducting elements connected in series and the balanced quenching of the superconducting elements was induced by connecting a neutral line.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

1선 지락사고에 대한 배전급 저항형 초전도 한류기의 전류제한특성 (Current Limiting Characteristics of a Resistive SFCL for a Single-line-to-ground Fault in the 22.9 kV System)

  • 최효상;황시돌;현옥배
    • 한국전기전자재료학회논문지
    • /
    • 제14권6호
    • /
    • pp.505-510
    • /
    • 2001
  • We simulated the current limiting characteristics of a resistive superconducting fault current limiter (SFCL) for a single line-to-ground fault in the 22.9 kV system. The transient current during the fault increased to 6.33 kA, 5.80 kA and 3.71 kA without SFCL at the fault angles 0$^{\circ}$, 45$^{\circ}$ and 90$^{\circ}$, respectively, a resistive SFCL limited effectively the fault current to 2.27 kA in a half cycle without any DC components. The maximum quench resistance of an SFCL, 16Ω was suggested to be appropriate to limit the fault current in the 22.9 kV distribution system, considering the operating cooperation of a protective relay and the current limiting performance of an SFCL.

  • PDF

초전도한류기의 신뢰도 모델에 관한 연구 (A Study on the Reliability Model of Superconducting Fault Current Limiter)

  • 배인수;김형주;이상교;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.393_394
    • /
    • 2009
  • 초전도한류기(SFCL)는 고장전류에 대한 초고속 감지, 고장전류 제한이 가능하고, 정상계통에서는 무손실 운영이 가능한 신개념의 기기이다. 공급신뢰도 측면에서 SFCL은, 고장전류 저감으로 송전을 지속할 수 있는 장점이 있는 반면, 기존 계통에 직렬연결되므로 자체 고장으로 인해 공급신뢰도를 악화시킬 수도 있다. 특히, 고속스위치를 필요로 하는 하이브리드형 SFCL의 경우 계통연계 이전에 SFCL 자체의 신뢰성이나 주위 계통에 미치는 영향을 미리 검토해야 한다. 본 논문에서는 SFCL의 신뢰도 데이터를 계산하는 기법과 SFCL 인근 설비의 신뢰도 데이터를 갱신하는 방법에 대해 제시하였으며, 이는 SFCL가 연계된 배전계통의 수용가 공급신뢰도를 산출하기 위해 필요한 사전단계에 해당한다.

  • PDF

초전도소자의 저항변화에 따른 반주기내 한류형 하이브리드 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of a Hybrid SFCL with the First Half Cycle Limiting Operation Due to Resistance of Superconducting Element)

  • 김진석;임성훈;김재철;최종수
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1817-1822
    • /
    • 2011
  • The fault current has been increasing due to expansive substation facilities for meeting the increase of demand. To limit increasing fault current in a power system, among methods the superconducting fault current limiter (SFCL) has been considered to be adopted in the power grid. However, in case of adopting SFCL in the power system, most of SFCLs need to solve problems such as recovery, cost. With efforts to solve those problems, the novel fault current limiting device which is called hybrid SFCL is developed. To apply the hybrid SFCL, it has to be needed to analyze application possibility and itself operation characteristics. In this paper, the fault current limiting and operation characteristics of hybrid SFCL with first half cycle the limiting operation in case of various resistances of superconducting element were analyzed through experiment.

코일의 자기결합을 이용한 초전도 사고전류제한기의 동작특성 (Operational Characteristics of SFCL using Magnetic Coupling of Coils)

  • 임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.68-70
    • /
    • 2007
  • The operational characteristics of superconducting fault current limiter (SFCL) using magnetic coupling of coils were investigated. This SFCL consists of a high-Tc superconducting (HTSC) element and two coils with series or parallel connection on the same iron. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the resistance of HTSC element comprising this SFCL increased more than that of HTSC element's independent operation.

  • PDF