• Title/Summary/Keyword: SFC test

Search Result 34, Processing Time 0.018 seconds

An Efficient Function of Self Test in PLC Control Designed by SFC (SFC로 설계된 PLC 제어에서 효율적인 자기진단 기능)

  • You, Jeong-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.153-158
    • /
    • 2008
  • When we design the control system used Programmable Logic Controller(PLC), we program the main algorithm by Ladder Diagram(LD) in many standard language. But if we use an Sequential Function Chart(SFC), we is easy to know the sequential flow of control, to maintenance the controller and to describe a program. Even though a SFC have many merits, A SFC have some problems like a condition and a function of self test. Therefore this thesis show an efficient function of self test and we confirmed its feasibility through actual example.

Growth of Lettuce and Young Radish and Changes of Soil Chemical Properties after Application of Soldier Fly Compost (동애등에분 처리 시 상추와 무의 생육 및 토양화학성 변화)

  • Young-Sun Kim;Geung-Joo Lee
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.2
    • /
    • pp.152-158
    • /
    • 2023
  • This study was conducted to evaluate the effects on soil chemical properties and plant growth after applying soldier fly compost (SFC). Treatments were as follows. No fertilizer (NF), control, SFC1 (SFC 250 kg/10a), SFC2 (SFC 500 kg/10a) and SFC3 (SFC 1,000 kg/10a). As compared to control in the pot test, organic matter (OM) and exchangeable sodium (Ex-Na) of SFC3 treatment were increased, and growth and nutrient uptake of young radish were not significantly different. Correlation coefficient between soil chemical factors like total nitrogen (T-N), OM, and CEC and uptake of nitrogen (N) and phosphorus (P) was significantly positive (p≤0.05). Compared to control in the field test, electrical conductivity, T-N, OM, Av.-P2O5, and CEC was increased, and lettuce growth was not significantly different. Correlation coefficient between application amount of SFC and T-N, OM, and Av.-P2O5 was significant positively (p≤0.05). These results indicated that the application of SFC improved nutrient availability of soil by increasing OM and CEC.

Flexural analysis of steel fibre-reinforced concrete members

  • Chalioris, Constantin E.;Panagiotopoulos, Thomas A.
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.11-25
    • /
    • 2018
  • A numerical approach for the evaluation of the flexural response of Steel Fibrous Concrete (SFC) cross-sections with arbitrary geometry, with or without conventional steel longitudinal reinforcing bars is proposed. Resisting bending moment versus curvature curves are calculated using verified non-linear constitutive stress-strain relationships for the SFC under compression and tension which include post-peak and post-cracking softening parts. A new compressive stress-strain model for SFC is employed that has been derived from test data of 125 stress-strain curves and 257 strength values providing the overall compressive behaviour of various SFC mixtures. The proposed sectional analysis is verified using existing experimental data of 42 SFC beams, and it predicts the flexural capacity and the curvature ductility of SFC members reasonably well. The developed approach also provides rational and more accurate compressive and tensile stress-strain curves along with bending moment versus curvature curves with regards to the predictions of relevant existing models.

Routing optimization algorithm for logistics virtual monitoring based on VNF dynamic deployment

  • Qiao, Qiujuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.5
    • /
    • pp.1708-1734
    • /
    • 2022
  • In the development of logistics system, the breakthrough of important technologies such as technology platform for logistics information management and control is the key content of the study. Based on Javascript and JQuery, the logistics system realizes real-time monitoring, collection of historical status data, statistical analysis and display, intelligent recommendation and other functions. In order to strengthen the cooperation of warehouse storage, enhance the utilization rate of resources, and achieve the purpose of real-time and visual supervision of transportation equipment and cargo tracking, this paper studies the VNF dynamic deployment and SFC routing problem in the network load change scenario based on the logistics system. The BIP model is used to model the VNF dynamic deployment and routing problem. The optimization objective is to minimize the total cost overhead generated by each SFCR. Furthermore, the application of the SFC mapping algorithm in the routing topology solving problem is proposed. Based on the concept of relative cost and the idea of topology transformation, the SFC-map algorithm can efficiently complete the dynamic deployment of VNF and the routing calculation of SFC by using multi-layer graph. In the simulation platform based on the logistics system, the proposed algorithm is compared with VNF-DRA algorithm and Provision Traffic algorithm in the network receiving rate, throughput, path end-to-end delay, deployment number, running time and utilization rate. According to the test results, it is verified that the test results of the optimization algorithm in this paper are obviously improved compared with the comparison method, and it has higher practical application and promotion value.

Evaluation of Microscopic Deformation Behaviors of Metal Matrix Composite due to Heat Treatment by means of SFC Test and Acoustic Emission (음향방출과 SFC 시험법에 의한 금속복합재료의 기지재 열처리 효과에 따른 미시적 변형기구 특성 평가)

  • Kang, Moon-Phil;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.381-389
    • /
    • 2000
  • Metal matrix composite(MMCs) have been rapidly becoming one of the strongest candidates for structural materials for high temperature application. It is well recognized that MMCs always experience at least one large cool-down from processing temperature before my significant applied service loading. Due to the large difference in thermal expansion coefficient between the fiber and matrix, large thermal residual stresses generally develop in composites. It was reported from many previous studies that the effects of thermal residual stress on mechanical properties and fracture behavior were much more complex and dramatic than conventional engineering materials. Therefore it is crucial to evaluate the effect of heat treatment which changes the characteristic of distribution of thermal residual stress in MMCs. Single fiber composite(SFC) test based on the balance in a micromechanical model is a quite convenient method to evaluate interfacial shear strength(IFSS) and the failure mode of composite. In this study the effect of heat treatment on IFSS and the microscopic failure mechanism of MMC is investigated by combining acoustic emission(AE) technique with SFC test. The characteristic of AE signal, IFSS and microscopic failure mechanism due to heat treatment condition is discussed.

  • PDF

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

Earthquake resistance of structural walls confined by conventional tie hoops and steel fiber reinforced concrete

  • Eom, Taesung;Kang, Sumin;Kim, Okkyue
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.843-859
    • /
    • 2014
  • In the present study, the seismic performance of structural walls with boundary elements confined by conventional tie hoops and steel fiber concrete (SFC) was investigated. Cyclic lateral loading tests on four wall specimens under constant axial load were performed. The primary test parameters considered were the spacing of boundary element transverse reinforcement and the use of steel fiber concrete. Test results showed that the wall specimen with boundary elements complying with ACI 318-11 21.9.6 failed at a high drift ratio of 4.5% due to concrete crushing and re-bar buckling. For the specimens where SFC was selectively used in the plastic hinge region, the spalling and crushing of concrete were substantially alleviated. However, sliding shear failure occurred at the interface of SFC and plain concrete at a moderate drift ratio of 3.0% as tensile plastic strains of longitudinal bars were accumulated during cyclic loading. The behaviors of wall specimens were examined through nonlinear section analysis adopting the stress-strain relationships of confined concrete and SFC.

Multi-factors Bidding method for Job Dispatching in Hybrid Shop Floor Control System

  • Lee, Seok--Hee;Park, Kyung-Hyun;Bae, Chang-Hyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.2
    • /
    • pp.124-131
    • /
    • 2000
  • A shop floor can be considered as and importand level to develop a Computer Integrated Manufacturing system (CIMs). The shop foor is a dynamic environment where unexpected events contrinuously occur, and impose changes to planned activities. The shop floor should adopt an appropriate control system that is responsible for scheduling coordination and moving the manufacturing material and information flow. In this paper, the architecture of the hybrid control model identifies three levels; i.e., the shop floor controller (SFC), the cell controller(CC) and the equipment controller (EC). The methodology for developing these controller is employ an object-oriented approach for static models and IDEF0 for function models for dispatching a job. SFC and CC are coordinated by employing a multi-factors bidding and an adapted Analytic Hierarchy Process(AHP) prove applicability of the suggested method. Test experiment has been conducted by with the shopfloor, consisting of six manufacturing cells.

  • PDF

A Cooperative Security Gateway cooperating with 5G+ network for next generation mBcN (차세대 mBcN을 위한 5G+ 연동보안게이트웨이)

  • Nam, Gu-Min;Kim, Hyoungshick;Lee, Hyun-Jin;Cho, Hark-Su
    • Journal of Internet Computing and Services
    • /
    • v.22 no.6
    • /
    • pp.129-140
    • /
    • 2021
  • The next generation mBcN should be built to cooperate with the wireless network to support hyper-speed and hyper-connectivity. In this paper, we propose a network architecture for the cooperation mBcN and 5G commercial network and architecture of the cooperative security gateway required for the cooperation. The proposed cooperative security gateway is between gNB and UPF to support LBO, SFC, and security. Our analysis shows that the proposed architecture has several advantages. First of all, user equipment connected with the mBcN can be easily connected through the 5G commercial radio network to the mBcN. Second, the military application traffic can be transmitted to mBcN without going through the 5G core network, reducing the end-to-end transmission delay without causing the traffic load on the 5G core network. In addition, the security level of the military application can effectively be maintained because the user equipment can be connected to the cooperative security gateway, and the traffic generated by the user equipment is transmitted to the mBcN without going through the 5G core network. Finally, we demonstrate that LBO, SFC, and security modules are essential functions of the proposed gateway in the 5G test-bed environment.

Study on the effect of Jet Fuel alteration on Turbine Engine Performances through Turbine Engine Test (터빈엔진시험을 통한 제트연료 변경에 따른 엔진성능 변화 연구)

  • Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.23-28
    • /
    • 2011
  • The engine ground and altitude tests were carried out to investigate the effect of jet fuel alteration on the performance of a small turbojet engine. JP-S was supplied 8% higher than JP-8 by fuel metering system at the same command. The employment of JP-S showed the similar starting characteristic to that of JP-8, however, difference in the ignition time and acceleration rate of engine speed due to the difference of fuel flow rate by fuel metering system was observed. In spite of jet fuel alteration, the test results yield the similar steady-state engine performance in net thrust, air flow, exhaust gas temperature, etc. On the other hand, the fuel consumption of JP-S increased by 5 % compared with that of JP-8. In point of specific fuel consumption (SFC), SFC of JP-S was approximately 1.1~2.6 %, 5 % higher than that of JP-8 in ground and altitude tests respectively at the same thrust.