• Title/Summary/Keyword: SEP

Search Result 1,146, Processing Time 0.026 seconds

Diagnostic Efficacy of a Recombinant Cysteine Protease of Spirometra erinacei Larvae for Serodiagnosis of Sparganosis

  • Rahman, S.M. Mazidur;Kim, Jae-Hwan;Hong, Sung-Tae;Choi, Min-Ho
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.1
    • /
    • pp.41-46
    • /
    • 2014
  • The mature domain of a cysteine protease of Spirometra erinacei plerocercoid larva (i.e., sparganum) was expressed in Escherichia coli, and its value as an antigen for the serodiagnosis of sparganosis was investigated. The recombinant protein (rSepCp-1) has the molecular weight of 23.4 kDa, and strongly reacted with the sparganum positive human or mice sera but not with negative sera by immunoblotting. ELISA with rSepCp-1 protein or sparganum crude antigen (SeC) was evaluated for the serodiagnosis of sparganosis using patient's sera. The sensitivity and specificity of ELISA using rSepCp-1 protein were 95.0% (19/20) and 99.1% (111/112), respectively. In contrast, the sensitivity and specificity of ELISA with SeC were 100% (20/20) and 96.4% (108/112), respectively. Moreover, in experimentally infected mice, the sensitivity and specificity of both ELISA assays were 100% for the detection of anti-sparganum IgG. It is suggested that the rSepCp-1 protein-based ELISA could provide a highly sensitive and specific assay for the diagnosis of sparganosis.

Disparities in Participation in Health Examination by Socio-economic Position among Adult Seoul Residents (사회경제적 위치에 따른 건강검진 수진율의 차이: 서울시 성인 거주자를 대상으로)

  • Chun, Eun-Jeong;Cho, Sung-Il;Cho, Young-Tae;Moon, Ok-Ryun;Jang, Soong-Nang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.5
    • /
    • pp.345-350
    • /
    • 2007
  • Objectives: To determine the disparity in the rate people undergo health examinations according to socioeconomic position (SEP) and the changes in this disparity with time. Methods: Seoul citizens' health profile data from 1997 to 2005 were analyzed. The study subjects were 40 years old and over, and the total number of subjects was 6,601 in 1997, 8,994 in 2001, and 8,819 in 2005. Those aged 60 years and over were eliminated from the analysis of subjects' occupation. We used education, family income and occupation as indicators of SEP. The age-standardized health examination attendance rate for each year was calculated according to the education, family income and occupation. The odds ratios (ORs) from multiple logistic regressions were adjusted for age. Results: The disparity in the rate of attendance according to the SEP decreased from 1997 to 2005 but still existed. Even though the disparities among the subgroups according to education, family income and occupation were not that high, the disparity between the group with the highest SEP and the other groups was considerable. Conclusions: Our findings suggest that unequal access to health examination services according to socioeconomic position still exists. This disparity has decreased recently but the disparity according to level of education was the greatest.

The Prediction of Blending Ratio of Cut Tobacco, Expanded Stem, and Expanded Cut Tobacco in Cigarettes using Near Infrared Spectroscopy (근적외분광법을 이용한 권련 중 일반각초, 팽화주맥 및 팽화각초 배합비 분석)

  • 김용옥;정한주;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • This study was carried out to predict blending ratio of cut tobacco(CT), expanded stem(ES), and expanded cut tobacco(ECT) in cigarettes. CT, ES, and ECT samples from A brand were, ground and blended with reference to A blending ratio, and scanned by near infrared spectroscopy(NIRSystem Co., Model 6500). Calibration equations were developed and then determined blending ratio by NIRS. The standard error of calibration(SEC) and performance(SEP) of C factory samples between NIRS and known blending ratio were 0.97%, 1.93% for CT, 0.50%, 1.12 % for ES and 0.68%, 1.10% for ECT, respectively. The SEP of CT, ES and ECT of Band D factory samples determined by C factory calibration equation were more inaccurate than those of C factory samples determined by C factory calibration equations. These results were caused by the difference of CT, ES and ECT spectra followed by each factory. The SEP of CT, ES and ECT of Band D factories determined by calibration equations derived from each factory samples were more accurate than those of determined by calibration equation derived from C factory samples. Each factory SEP of CT, ES and ECT determined by calibration equation derived from all calibration samples(B+C+D factory) was similar to that determined by calibration equation derived from each factory samples. To improve the analytical inaccuracy caused by spectra difference, we need to apply a specific calibration equation for each factory sample. Data in development of specific calibrations between sample and NIRS spectra might supply a method for rapid determination of blending ratio of CT, ES, and ECT.

  • PDF

Seasonal survey on the respiratory diseases of slaughtered pigs in Jeonbuk, Korea (전북지역 도축돈 호흡기질병 조사)

  • Lim, Mi-Na;Kim, Chul-Min;Park, Young-Min;Song, Ju-Tae;Jin, Jae-Kwon;Cho, Hyun-Ung
    • Korean Journal of Veterinary Service
    • /
    • v.39 no.4
    • /
    • pp.231-237
    • /
    • 2016
  • The present study was conducted to investigate the lesion of red internal organs in slaughtered pigs and provided assistant data for pig farms. During March to December 2015, a total of 1,160 lung samples out of 58 herds were collected randomly from pigs slaughtered in Jeonbuk province. In addition, 290 hilar lymph nodes from pig with pneumonic lung lesion (5 samples per herd) were screened for selected viral and bacterial pathogens. Gross lesions of lungs such as swine enzootic pneumonia (SEP), pleuritis, pleuropneumonia, pericarditis and liver white spots were examined. The overall prevalence of SEP was 64.3% (746/1,160). In the analysis of seasonal prevalence, there was an increase of occurrence during the spring months (287/400, 71.8%) and decrease during the fall months (93/200, 46.5%) among the whole herds. The mean number of SEP score per pig was $1.20{\pm}1.28$. The prevalence of pleuropneumonia, pleuritis, pericarditis, and milk spot was 25.5% (296/1,160), 44.1% (512/1,160), 3.8% (44/1,160) and 17.6% (204/1,160), respectively. The most frequent region with lung lesion was diaphragmatic lobes (left 17.1%, right 17.3%). In the detection of viral pathogens by PCR, porcine circovirus type2 (PCV2) was positive in 86.9% (252/290), while porcine reproductive and respiratory syndrome virus (PRRSV) was not detected, In the case of bacterial pathogens, 50 microorganisms were isolated by PCR and/or microbiological test. The most frequently isolated bacteria was Streptococcus suis (20, 34.4%), followed by Pasteurella multocida (17, 29.3%), Streptococcus spp. (11, 3.4%), Actinobacillus pleuropneumoniae (2, 8.9%).

Somatosensory evoked potentials are abnormal with plagiocephaly

  • Harma, Maiju;Lauronen, Leena;Leikola, Junnu;Hukki, Jyri;Saarikko, Anne
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.59-63
    • /
    • 2022
  • Background: Deformational plagiocephaly is usually managed conservatively, as it tends to improve over time and with the use of conservative measures. However, before the year 2017 we operated on patients with severe plagiocephaly and neurological symptoms at the Helsinki Cleft Palate and Craniofacial Center. Methods: Of the 20 infants with severe deformational plagiocephaly and neurological symptoms referred to us between 2014 and 2016, 10 underwent cranioplasty open reshaping of the posterior cranial vault. The parents of the last 10 patients were given information on the natural history of the condition and the patients were followed up with an outpatient protocol. The aim of this study was to gain information on the brain electrophysiology and recovery of patients after total cranial vault reconstruction by measuring the electroencephalogram (EEG) somatosensory evoked potentials (SEP; median nerve). Results: Of the 10 participants in the operation arm, six had abnormal SEP at least on the affected cerebral hemisphere and all SEPs were recorded as normal when controlled postoperatively. In the follow-up arm, eight out of 10 participants had abnormal SEP at the age of approximately 24 months, and all had normalized SEPs at control visits. Conclusion: Our data suggest that cranioplasty open reshaping of the posterior cranial vault did not affect abnormal SEP-EEG recordings. We have abandoned the operations in deformational plagiocephaly patients due to findings suggesting that expanding cranioplasty is not beneficial for brain function in this patient group.

The study of nondestructive method for measuring the acidity of the recent record paper in Hanji by using FT-NIR spectroscopy and Integrating sphere (푸리에 변환 근적외선 분광분석기(FT-NIR)와 적분구를 이용한 근대 한지 기록물의 산성도 비파괴 평가방법에 대한 연구)

  • Shin, Yong-Min;Park, Soung-Be;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.255-269
    • /
    • 2011
  • The purpose of study has to analyze with non destructive method for researching the tool that could be measured with the status of record written on Hanji speedily. Because the original record should be destructed for analyzing with previous method in the case of the paper record, it was to develop the tool based on non destructive method for overcoming such limit. The study was used with FT NIR (Fourier transform NIR) for analyzing the Hanji for being written and preserved. The FT NIR spectrometer that of NIR spectrometer has the better performance of precision and accuracy than dispersive NIR spectrometer was used. Also the wavelength of FT-NIR was measured with 12,500 to 4,000 $cm^{-1}$, and the integrating sphere as diffuse reflectance type was used for analyzing Hanji. The moisture and acidity (pH) of chemical factors as quality evaluated factor of Hanji was studied for the correlation of NIR spectrum. And then The NIR spectrum was pretreated for showing the coefficients of optimum correlation. MSC and First derivative of Savitzky - Golay was used as pretreated method, and the coefficients of optimum correlation were shown by PLSR(Partial least square regression). And the coefficients of optimum correlation were calculated by PLSR(Partial least square regression). The correlation coefficients of acidity had 0.92 on NIR spectra without pretreatment. Also the SEP of acidity was 0.24. And then The NIR spectra with pretreatment would have more good correlation coefficients ($R^2=0.98$) and more good SEP(=019) on acidity. Therefore the data of correlation coefficients ($R^2$) and SEP with pretreatment was shown to be superior. And NIR spectra data of first derivative had best linearity on the correlation coefficients ($R^2=0.99$) and also SEP(=0.45) was superior. Therefore the correlation coefficients and SEP of first derivative had better than those of NIR spectra of no pretreatment. As such result, it was possible to evaluate the record status of Hanji speedily with integrated sphere and NIR analyzer as non destructive method.

  • PDF

A Study on the Determination of Caffeine in Coffee, Black tea and Green Tea by high performance Liquid Chromatography (고속액체 크로마토크래피에 의한 커피, 홍차, 녹차중의 카페인 정량에 관한 연구)

  • 권익부;이윤수;우상규;이충영;서준걸
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.4
    • /
    • pp.213-217
    • /
    • 1990
  • A simple and practical method for the determination of caffeine in coffee, black tea and green tea was studied. The analysis of caffeine was performed by reverse phase high perfomance liquid chromatography using a ${\mu}-Bondapak$ C18 column at isocratic condition with methanol-acetic acid-water (20: 1: 79) on UV detector at 280 nm. The extraction and clean-up of caffeine in sample is based on combing a simple pretreatment with the use of a Sep-Pak Alumina A cartridge. The average recoveries of caffeine from several samples were 95.2 -101.3%, the relative standard deviation for the whole procedure was 0.10 ~ 0.62%, and the detection limit of caffeine in sample solution was about $0.1\;\mu\textrm{g}\;per\;ml$.

  • PDF

Nondestructive Prediction of Fatty Acid Composition in Sesame Seeds by Near Infrared Reflectance Spectroscopy

  • Kim, Kwan-Su;Park, Si-Hyung;Choung, Myoung-Gun;Kim, Sun-Lim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.304-309
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) was used to develop a rapid and nondestructive method for the determination of fatty acid composition in sesame (Sesamum indicum L.) seed oil. A total of ninety-three samples of intact seeds were scanned in the reflectance mode of a scanning monochromator, and reference values for fatty acid composition were measured by gas-liquid chromatography. Calibration equations were developed using modified partial least square regression with internal cross validation (n=63). The equations obtained had low standard errors of cross-validation and moderate $R^2$ (coefficient of determination in calibration). Prediction of an external validation set (n=30) showed significant correlation between reference values and NIRS estimated values based on the SEP (standard error of prediction), $r^2$ (coefficient of determination in prediction) and the ratio of standard deviation (SD) of reference data to SEP. The models developed in this study had relatively higher values (more than 2.0) of SD/SEP(C) for oleic and linoleic acid, having good correlation between reference and NIRS estimate. The results indicated that NIRS, a nondestructive screening method could be used to rapidly determine fatty acid composition in sesame seeds in the breeding programs for high quality sesame oil.

Determination of Rice Milling Ratio by Visible / Near-Infrared Spectroscopy (가시광선 / 근적외선 분광 분석법을 이용한 쌀의 정백수율 측정)

  • 김재민;민봉기;최창현
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.333-342
    • /
    • 1997
  • The objective of this research was to develop model equations for measuring rice milling ratio by using visible / HIR spectroscopy. Twelve kinds of brown rice(n = 149) were milled to obtain various milling ratio ranged from 86% to 94%. Visible/NIR spectra were collected with a spectrophotometer with sample transport module. The reflectance and transmission spectra were measured in the range of 400~2, 500nm and 600~1, 400nm, respectively, with 2 nm intervals. Multiple linear regression(MLR), Partial least square (PLS), and Artificial neural network(ANN) were used to develop models. Model developed with reflectance spectra showed better prediction results then those with transmission spectra. The MLR model with six-wavelength obtained from first derivative spectra gave to the best results for measuring the rice milling ratio(SEP = 0.535, , $r^2$ = 0.980). The PLS model(SEP = 0.604, $r^2$= 0.976) and ANN model(SEP = 0.566, $r^2$= 0.978) also can be used to determine the rice milling ratio effectively.

  • PDF

Analysis of Carbendazim and Carbaryl by Micro-HPLC (Micro-HPLC에 의한 Carbendazim과 Carbaryl의 분석)

  • Choi, Kyoung-Sook;Lee, Hoe-Yeon;Lee, Duck-Hee;Byun, Woon-Ki
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.421-425
    • /
    • 1994
  • A micro-high performance liquid chromatography(Micro-HPLC) techniquie with solid phase extraction was reported which detected carbendazim and carbaryl at picogram levels. They were separated on microbore packed $C_{18}$ column($1.0mm\;I.\;D{\times}150mm$, $d_f=5{\mu}m$) using a 50% methanol mobile phase and detected at UV 220nm(${\alpha}=2.94$, $R_s=4.71$), while they were not resolved on analtical HPLC system(${\alpha}=1.27$, $R_s=0.76$). The detection thresholds of carbendazim and carbaryl were 0.5ng and 0.1ng on Micro-HPLC, therefore Micro-HPLC system was 20~40 told more sensitive than anayltical HPLC system. Sep-Pak $C_{18}$ catridge was found to be efficient in enriching carbendazim and carbaryl from dilute aqueous solution with 97.0% and 97.8% recoveries of them. The Sep-Pak $C_{18}$ catridge followed by the Micro-HPLC had been applied to the quantitative analysis of carbendazim and carbaryl in spiked juices and a commercial drinking water.

  • PDF