Adsorption properties and metal growth aspects on the surface of activated carbon monolith electrochemically deposited with Ag

  • Oh, Won-Chun;Lim, Chang-Sung
    • 한국결정성장학회지
    • /
    • 제14권2호
    • /
    • pp.37-46
    • /
    • 2004
  • The electrochemical adsorption of the Ag ions from aqueous solution on pelletized activated carbon monolith was investigated over wide range of operation time. The adsorption capacities of pelletized activated carbon monolith are associated with their internal porosity and are related properties such as surface area, pore size distribution. The chemical industry generates wastewater that contains toxic matters like heavy metals in small concentrations so that their economic recovery is not feasible. But, the method using activated carbon monolith can be used to withdrawal of heavy metals in waste water. After the electrochemical treatment, the quantitative properties in Ag ion solutions are also examined by pH concentration and studied elemental analysis by ICP-Atomic Emission Spectrometer and Energy Disperse X-ray (EDX) spectra. It is consider that the pH is very important factor at the reason of water pollutant with increasing acidity in industrial field. The result of quantitative analysis using Inductively Coupled Plasma-Atomic Emission Spectrometer of metal after electrochemical reaction in Ag ions solution depending on time are shown that the amount of Ag ions deposited was decreased with growth of Ag particles on the carbon surfaces as increasing electrochemically treated time. And, surface morphologies are investigated by scanning electron microscopy (SEM) to explain the changes in adsorption properties.

실리카 양 변화에 의한 난연성 실리콘 고무의 유전특성에 관한 연구 (A Study on Dielectric Properties of Flame-Retardant Silicone Rubber Due to Silica Amount Change)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.364-370
    • /
    • 2021
  • In this study, the dielectric properties of flame retardant silicone rubber mixed with the amount of silica 50~65 phr were measured at frequencies ranging from 1 to 2.7 MHz and temperature ranges from 30℃ to 160℃. The permittivity decreased with higher frequencies and higher temperatures, and tanδ are thought to have decreased due to the increased heat oxidation of the methyl group bound to Si, which increased the hardness of silicone rubber. FT-IR analysis of specimen mixed with SiO2 of 50~65 phr showed oscillations of OH groups bound to SiO2 between wavenumber 3,600 and 3,300. As a result of analyzing surface components by Energy Dispersive X-ray (EDX) on all specimens mixed with SiO2 of 50 to 65 phr, all specimens contained Si, and the analysis by field emission scanning electron (FE-SEM) confirmed that about 1~5 ㎛ particles were distributed regularly on the surface of the specimens.

저압용 누전차단기의 차단특성 및 그라파이트 분석에 관한 연구 (A Study on the Cut Off Characteristics and Graphite Analysis of Residual Current Protective Devices for Low Voltage)

  • 최충석;이경섭;정재희;박수홍;김병수;이덕출
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.49-54
    • /
    • 1999
  • In this paper. we studied cut off characteristics and fire hazard of residual current protective devices(RCD or ELB) for low voltage. The operative time of RCD with grounding resistance was analyzed by using RCD operating tester. The surface structure and composition of insulator were analyzed by using scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of phenol resin showed network structure and void. The spectra shown in EDX analysis are composed not only of the corresponding elements but also of several new spectra, as CK. OK$\alpha$. MgK, SiK. and CaK, which were absent in original material.

  • PDF

점토를 매개체로 한 탄산칼슘 석출 및 흙의 고결에 관한 연구 (A Study on Soil Cementation and Calcite Precipitation with Clay as a Medium)

  • 박성식;서은희;채경헌;장상규;김진호
    • 한국지반공학회논문집
    • /
    • 제31권12호
    • /
    • pp.17-27
    • /
    • 2015
  • 본 연구에서는 식물추출액을 이용하여 요소를 분해한 다음 이로부터 분해된 탄산이온과 수용액 상태의 칼슘이온이 음전하를 띄는 점토를 매개체로 하여 탄산칼슘을 석출시켜 친환경적으로 흙을 고결시키면서 내구성도 향상시키는 연구를 수행하였다. 식물추출액과 요소가 혼합된 제1용액과 칼슘원(염화칼슘)이 용해된 용액에 소량의 점토가 혼합된 제2용액을 깨끗한 낙동강모래에 섞어서 비빈 다음 다짐방법으로 소형 공시체를 제작하였다. 요소와 염화칼슘의 몰농도를 세 종류(1, 5, 7몰)로 달리하였으며, 각 공시체에 점토를 전체중량의 0%, 1%, 3%의 세가지 비율로 혼합하여 공시체를 제작한 다음 실내에서 7일 동안 양생하였다. 양생이 완료된 공시체에 대해 일축압축시험, 내구성시험, SEM, EDX 및 XRD 분석, 그리고 열중량 분석을 실시하여 사질토의 고결 정도와 구조를 분석하였다. 요소와 염화칼슘의 몰농도가 높을수록 점토 함유량이 증가할수록 일축압축강도와 내구성이 증가하는 경향을 보였다. SEM, EDX 및 XRD 분석을 통하여 점토광물 주변에 탄산칼슘(calcite)이 석출되는 것을 확인하였으며, 열중량 분석으로부터 시료 내에 중량대비 탄산칼슘이 1-2% 정도 석출되었다.

Surface Characteristics and Biocompatibility of Titanium Coated with Dentin-derived Hydroxyapatite

  • Kim, Hae-Jin;Son, Mee-Kyung;Lee, Kyung-Ku;Lee, Bo-Ah;Kim, Young-Joon
    • International Journal of Oral Biology
    • /
    • 제37권1호
    • /
    • pp.9-16
    • /
    • 2012
  • The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at $850^{\circ}C$. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM) and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate-buffered saline at a $36.5{\pm}1^{\circ}C$ in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was $0.27{\mu}m$ and, $1.7{\mu}m$, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93% cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

전차선로 드로퍼 클램프 파단 원인 분석 (The Cause Analysis on Fracture of Dropper Clamp in Catenary System)

  • 김정남;권성태;강계명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.909-914
    • /
    • 2004
  • This study investigate the cause analysis on fracture of dropper clamp in catenary system. Dropper clamp is using as a holder between messenger wire and contact wire in catenary system. To analyze the cause analysis on fracture of dropper clamp, we have conducted experiment such as tension withstand strength test, holding strength test of a new products, SEM and EDX of field fractured specimens.

  • PDF

수도권 전철구간에서 발생한 조가선 절단원인 분석 (The cause analysis of broken accident on messenger wire in catenary system)

  • 장동욱;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.552-557
    • /
    • 2003
  • The catenary system used in urban electrification railway have suffered mechanical and chemical stresses. These brought out severe messenger wire problems, these have caused accident. Especially, messenger wire is severely influenced by corrosion, vibration and tension. This paper investigate for the cause analysis of broken accident on messenger wire in catenary system. To analyze the cause analysis of accident, we have conducted experiment such as XRD, SEM, EDX and tensile test.

  • PDF

티타늄 소강판 주위조직에 발생한 색소침착의 성질에 관한 연구 (A STUDY FOR THE NATURE OF PIGMENTATION ADJACENT TO TITANIUM MINIPLATE OSTEOSYNTHESIS)

  • 원동환;주현호;이상휘;김일현
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권1호
    • /
    • pp.25-31
    • /
    • 2001
  • The titanium miniplate osteosynthesis system has been used for fixation of bone fragments in the maxillofacial areas due to easy manipulation and even has been proposed for unnecessity of miniplate removal because of the biocompatibility and the corrosion resistance. But recently, there have been some suggestions for its removal, on the basis of findings that there have been pigmentations around the adjacent tissues during miniplate removal procedure and they are the depositions of metal particles. Purposes of this study are to ascertain the presence and nature of pigmentation observed within tissues adjacent to titanium miniplate, and to suggest possible causes of it. We could observe the black pigmentation during miniplate removal procedure for recent about 1.5 year. Pigmented tissues were stained with hematoxylin-eosin(H-E) for light microscophic(LM) examination to investigate the black pigmentations and the histomorphology around them. The scanning electron microscopy(SEM) with energy dispersive X-ray(EDX) analysis was used to examine the ultrastructural nature of pigmentations. Many metal particles with variable sizes and shapes were seen in the connective tissue by SEM and were identified as titanium by EDX.

  • PDF

Characteristics of Surface Modified Activated Carbons Prepared by Potassium Salt Sequentially After Hydrochloric Acid Treatment

  • Oh, Won-Chun;Park, Chong-Sung;Bae, Jang-Soon;Ko, Young-Shin
    • Carbon letters
    • /
    • 제7권1호
    • /
    • pp.34-41
    • /
    • 2006
  • The objective of this paper is to compare the variation of surface properties by hydrochloric acid pre-treatment and of metallic potassium and their salts loading effect for activated carbon after surfaces transformation by acid. From the results of nitrogen adsorption, each isotherm shows a distinct knee band, which is closely related to the characteristic of microporous carbons with capillary condensation in micropores. In order to present the causes of the differences in surface properties and $S_{BET}$ after the samples were treated with hydrochloric acid, pore structure and surface morphology are investigated by adsorption analysis. X-ray diffraction (XRD) patterns indicate that activated carbons show better performance for metallic potassium and potassium salts by pre-treatment with hydrochloric acid. Scanning electron microscopy (SEM) pictures of potassium/activated carbon particles provide information about the homogeneous distribution of metal or metal complex on the surface. For the chemical composition microanalysis for potassium treatment of the activated carbon pre-treated with hydrochloric acid, samples were analyzed by energy disperse X-ray (EDX). Finally, the type and quality of oxygen groups are determined from the method proposed by Boehm. A positive influence of the acidic groups on the carbon surface by acid treatment is also demonstrated by an increase in the contents of potassium salts with increasing of acidic groups calculated from Boehm titration.

  • PDF

악취가스 및 휘발성 유기 화합물 산화를 위한 백금계 촉매의 코팅 방법에 관한 연구 (A Study on the Coating Method of Platinum based Catalyst for Odor Gas and VOCs Oxidation)

  • 신중훈;정민기;홍성창
    • 공업화학
    • /
    • 제32권5호
    • /
    • pp.497-503
    • /
    • 2021
  • 본 연구에서는 악취가스 및 휘발성 유기 화합물을 산화 제거하기 위한 백금/티타니아를 허니컴 및 메탈폼 담체에 코팅하는 방법을 확인하였다. 다양한 방법 중 파우더 코팅과 나노 코팅에 대한 비교를 수행하였다. SEM/EDX (Scanning Electron Microscopy/Energy Dispersive X-ray spectroscopy) 분석은 허니컴 및 메탈폼의 표면 상태 및 노출된 백금 성분비를 조사하는데 사용되었다. 또한, 촉매 코팅 방법에 따른 톨루엔, 트리메틸아민, 아이소프로필 알코올의 제거 성능을 비교하였다.