• Title/Summary/Keyword: SEM images

Search Result 624, Processing Time 0.022 seconds

Optimization of FSW of Nano-silica-reinforced ABS T-Joint using a Box-Behnken Design (BBD)

  • Mahyar Motamedi Kouchaksarai ;Yasser Rostamiyan
    • Advances in nano research
    • /
    • v.14 no.2
    • /
    • pp.117-126
    • /
    • 2023
  • This experimental study investigated friction stir welding (FSW) of the acrylonitrile-butadiene-styrene (ABS) T-joint in the presence of various nano-silica levels. This study aim to handle the drawbacks of the friction stir welding (FSW) of an ABS T-joint with various quantity of nanoparticles and assess the performance of nanoparticles in the welded joint. Moreover, the relationship between the nanoparticle quantity and FSW was analyzed using response surface methodology (RSM) Box-Behnken design. The input parameters were the tool rotation speed (400, 600, 800 rpm), the transverse speed (20, 30, 40 mm/min), and the nano-silica level (0.8, 1.6, 2.4 g). The tensile strength of the prepared specimens was determined by the universal testing machine. Silica nanoparticles were used to improve the mechanical properties (the tensile strength) of ABS and investigate the effect of various FSW parameters on the ABS T-joint. The results of Box-Behnken RSM revealed that sound joints with desired characteristics and efficiency are fabricated at tool rotation speed 755 rpm, transverse speed 20 mm/min, and nano-silica level 2.4 g. The scanning electron microscope (SEM) images revealed the crucial role of silica nanoparticles in reinforcing the ABS T-joint. The SEM images also indicated a decrease in the nanoparticle size by the tool rotation, leading to the filling and improvement of seams formed during FSW of the ABS T-joint.

Mechanical and Electrical Properties of Nonwoven Coated with CNFs/PVDF-HFP Composite (탄소나노섬유/PVDF-HFP 복합재로 코팅된 부직포의 역학적 및 전기적 특성 변화)

  • Lee, Sun-Hee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.2
    • /
    • pp.279-284
    • /
    • 2011
  • In this study, the process of preparation nonwoven with coated carbon nano fibers (CNFs) /poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) composite solution is described. The various contents of CNFs/PVDF-HFP composite coated nonwoven were prepared and characterized by morphological, mechanical, and electrical methods. Nonwovens are coated with CNFs/PVDF-HFP composite solution and decreased the pick up ratio with increasing CNFs contents in range from 0% to 16%. In the results of SEM images, it was clear that the CNFs were evenly distributed in coated nonwoven by SEM images, the existence of CNFs in coated nonwoven was confirmed regularly. The mechanical properties of various contents of CNFs/PVDF-HFP coated nonwoven were examined. The tensile linearity and compression linearity increased with increasing CNFs contents. The electrical properties of the CNFs/PVDF-HFP coated nonwoven increased with increasing CNFs contents.

An investigation into the application of fractals for rock roughness estimation

  • Pal S. K.;Chakravarty D.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.66-71
    • /
    • 2003
  • Profiles of naturally fractured surfaces of three sedimentary rock samples were plotted from the measured data using a mechanical profilometer. Fractal dimension of these profiles were computed and statistical F-test indicates that fractal dimension (FD) values can be used as a parameter for distinguishing the rock types. The comparison between FD values and a commonly used profile-roughness parameter called the Mayer's $Z_2$ parameter shows the superiority of the FD values as roughness estimator. Two-dimensional fractal roughness parameters of the same naturally fractured rock surfaces were also studied from their scanning electron microscopic (SEM) images at various magnification levels. The most suitable level of magnification of the SEM images for the study of the 2-D fractal roughness parameter was identified. The values of 2-D fractal roughness parameter for three different rocks were also compared using different methods of fractal dimensioning.

  • PDF

Damage Profile of HDPE Polymer using Laser-Induced Plasma

  • Tawfik, Walid;Farooq, W. Aslam;Alahmed, Z.A.
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.50-54
    • /
    • 2014
  • In this paper we studied the laser-induced crater depth, mass, and emission spectra of laser-ablated high-density polyethylene (HDPE) polymer using the laser-induced plasma spectroscopy (LIPS) technique. This study was performed using a Nd:YAG laser with 100 mJ energy and 7 ns pulse width, focused normal to the surface of the sample. The nanoscale change in ablated depth versus number of laser pulses was studied. By using scanning electron microscope (SEM) images, the crater depth and ablated mass were estimated. The LIPS spectral intensities were observed for major and minor elements with depth. The comparison between the LIPS results and SEM images showed that LIPS could be used to estimate the crater depth, which is of interest for some applications such as thin-film lithography measurements and online measurements of thickness in film deposition techniques.

THE EFFECTS OF DESENSITIZING AGENTS AND TOOTH BRUSHING ON DENTIN PERMEABILITY, IN VITRO (지각과민 처치제 도포 후 칫솔질에 의한 마모가 상아질 투과도에 미치는 영향)

  • Lee Jong-Wook;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.208-219
    • /
    • 2001
  • To study the effect of dentin permeability on a tooth with wear from tooth brushing after application of desensitizing agent, extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance, scanning electron microscope images(SEM) and atomic force microscope images(AFM) were compared and contrasted before and immediately after the application of desensitizing agent and after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study ; they were Gluma, Seal & Protect, All-Bond 2 and MS Coat. The results of this study are as follows. 1. On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent. 2. Except the specimens treated with MS Coat, the remaining specimens had an increase in dentin permeability after tooth brushing for 1 and 2 weeks but a decrease after 6 weeks. 3. The specimens treated with MS Coat had statistically significant increase in the dentin permeability regardless with the duration of tooth brushing. 4. On examination of SEM and AFM, the dentinal tubule diameter had decreased after treatment of desensitizing agents. The specimens other than those treated with MS Coat, smear layers were noted after tooth brushing. It is not always consistant but the hydraulic conductance correlated with the images from SEM and AFM.

  • PDF

The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs

  • Lee, Ji-Yoon;Kim, Kyoung-Hwa;Park, Shin-Young;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Rhyu, In-Chul;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.319-329
    • /
    • 2019
  • Purpose: Direct application of atmospheric-pressure plasma jets (APPJs) has been established as an effective method of microbial decontamination. This study aimed to investigate the bactericidal effect of direct application of an APPJ using helium gas (He-APPJ) on Porphyromonas gingivalis biofilms on sandblasted and acid-etched (SLA) titanium discs. Methods: On the SLA discs covered by P. gingivalis biofilms, an APPJ with helium (He) as a discharge gas was applied at 3 different time intervals (0, 3, and 5 minutes). To evaluate the effect of the plasma itself, the He gas-only group was used as the control group. The bactericidal effect of the He-APPJ was determined by the number of colony-forming units. Bacterial viability was observed by confocal laser scanning microscopy (CLSM), and bacterial morphology was examined by scanning electron microscopy (SEM). Results: As the plasma treatment time increased, the amount of P. gingivalis decreased, and the difference was statistically significant. In the SEM images, compared to the control group, the bacterial biofilm structure on SLA discs treated by the He-APPJ for more than 3 minutes was destroyed. In addition, the CLSM images showed consistent results. Even in sites distant from the area of direct He-APPJ exposure, decontamination effects were observed in both SEM and CLSM images. Conclusions: He-APPJ application was effective in removing P. gingivalis biofilm on SLA titanium discs in an in vitro experiment.

Three Dimensional Reconstruction of Structural Defect of Thin Film Transistor Device by using Dual-Beam Focused Ion Beam and Scanning Electron Microscopy (집속이온빔장치와 주사전자현미경을 이용한 박막 트랜지스터 구조불량의 3차원 해석)

  • Kim, Ji-Soo;Lee, Seok-Ryoul;Lee, Lim-Soo;Kim, Jae-Yeal
    • Applied Microscopy
    • /
    • v.39 no.4
    • /
    • pp.349-354
    • /
    • 2009
  • In this paper we have constructed three dimensional images and examined structural failure on thin film transistor (TFT) liquid crystal display (LCD) by using dual-beam focused ion beam (FIB) and IMOD software. Specimen was sectioned with dual-beam focused ion beam. Series of two dimensional images were obtained by scanning electron microscopy. Three dimensional reconstruction was constructed from them by using IMOD software. The short defect between Gate layer and Data layer was found from the result of three dimensional reconstruction. That phenomena made the function of the gate lost and data signal supplied to the electrode though the Drain continuously. That signal made continuous line defect. The result of the three dimensional reconstruction, serial section, SEM imaging by using the FIB will be the foundation of the next advanced study.

Quantification Analysis of Element Surface by Fractal Dimension (프랙탈 차원에 의한 소자 표면의 정량화 분석)

  • Kyung-Jin, Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.1
    • /
    • pp.145-149
    • /
    • 2023
  • High-resolution images of surfaces provide detailed information on pores or shapes with specific sizes ranging from nano sizes to micrometers. However, it is not yet clear to determine an efficient association for pores or shapes from high-resolution images of surfaces. For the efficient association of pores and shapes, the surface characteristics of the device were considered as fractal dimensions by taking SEM photographs and binarizing the images. The fractal program was directly coded for surface analysis of the device. The device surface characteristics and electrical characteristics are thought to be related to the fractal dimension. The fractal dimension decreased with an increase in internal pores. The density and grain boundary of particles, which are structural characteristics of the device surface, were related to the fractal dimension. The particle size decreased with an increase in the fractal dimension and was uniformly formed. When the particles were uniformly formed, fewer pores were present and the fractal dimension increased.

Neural Network Recognition of Scanning Electron Microscope Image for Plasma Diagnosis (플라즈마 진단을 위한 Scanning Electron Microscope Image의 신경망 인식 모델)

  • Ko, Woo-Ram;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.132-134
    • /
    • 2006
  • To improve equipment throughput and device yield, a malfunction in plasma equipment should be accurately diagnosed. A recognition model for plasma diagnosis was constructed by applying neural network to scanning electron microscope (SEM) image of plasma-etched patterns. The experimental data were collected from a plasma etching of tungsten thin films. Faults in plasma were generated by simulating a variation in process parameters. Feature vectors were obtained by applying direct and wavelet techniques to SEM Images. The wavelet techniques generated three feature vectors composed of detailed components. The diagnosis models constructed were evaluated in terms of the recognition accuracy. The direct technique yielded much smaller recognition accuracy with respect to the wavelet technique. The improvement was about 82%. This demonstrates that the direct method is more effective in constructing a neural network model of SEM profile information.

  • PDF