• Title/Summary/Keyword: SEM (scanning electron microscope)

Search Result 1,887, Processing Time 0.029 seconds

Chip Formation of WC-Co on Micro-cutting in SEM (SEM내 미소절삭에 의한 초경합금재의 칩 생성 기구)

  • 허성중;김원일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.604-607
    • /
    • 2003
  • This study investigates the micro-cutting of cemented carbides using PCD(polycrystalline diamond) and PCBN(polycrystalline cubic boron nitride) cutting tools are performed with SEM direct observation method. The purpose of this study is to make clear the cutting mechanism of cemented carbides and the fracture of WC particles at the plastic deformation zone in orthogonal micro-cutting. And also to achieve systematic understanding, the effect of machining parameter on chip formation and machined surface was investigated, including cutting speed. depth of cut and various tool rake angle.

  • PDF

3D Surface Model Generation of Micro Structure by Self Calibration of The SEM Image (SEM 영상의 자체검정에 의한 미세구조물의 3차원 표면모델 생성)

  • 이효성;박형동
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.151-159
    • /
    • 2003
  • This study presents method for self-calibration of the SEM(Scanning Electron Microscope) stereo image using the standard microprobe with same grid pattern and using parallel and central perspective projection equation. Result showed that parallel projection method is more suitable for standard microprobe. The maximum error of 3D coordinates acquired by this method did not exceed 5 $\mu\textrm{m}$, and DSM(Digital Surface Model) for three dimensional measurement of the rock sample was generated by the digital photogrammetry. This result can be used for quantification of micro scale change of shape and analysis of the micro morphology of rock due to weathering.

  • PDF

A study on corrosion mechanism of water steel pipes using SEM (SEM을 이용한 상수도 금속관 부식거동에 관한 연구)

  • 황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.53-60
    • /
    • 2002
  • This experiment was performed to investigate the characteristics of corrosion mechanism of water steel pipes using SEM(Scanning Electron Microscope) from March 1. 2002 to November 30. The characteristics shown in these results can be summarized as the following: 1. When I investigated to the characteristics of iron pipes and zinc pipes using a SEM, I could be found that there was a distintion in interface between an iron pipe and the scale, and that a zinc pipe wears a dark color. 2. I find much rate of $Fe_2O_3$ and a little rate of FeS as corrosion products, but I hardly find $FeCO_3$without carbon. 3 It was found that the oxide corrosion rate was 0.2~0.3mm/year. And then A-1 was 0.323mm/year that was very high.

Study on Cutting Characteristics of WC-Co with Micro Cutting in SEM (SEM 내 마이크로 절삭에 의한 초경합금재의 절삭 특성에 관한 연구)

  • 허성중
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.74-81
    • /
    • 2003
  • This paper describes that the micro-cutting of WC-Co using PCD (Polycrystalline Diamond) and PcBN (Polycrystalline Cubic Boron Nitride) cutting tools are performed with SEM(Scanning Electron Microscope) direct observation method. The purpose of this study is to present reasonable cutting conditions to obtain precise finished surface and machining efficiency. Summary of the results are shown below: (1) The thrust cutting forces tend to increase more than the principal forces as the depth of cut and the cuttlllg speed are increased preferably on orthogonal microcutting. (2) The tool wear in the flank face was formed larger than that in the rake face on orthogonal micro cutting. (3) The wear appearance for PCD tools is abraded by hard WC particles of the work materials, which lead diamond grain to be detached from the bond.

An Analysis of Tribological Properties of Metal Interlayered DLC Films Prepared by PECVD Method (PECVD로 증착된 금속층을 포함하는 DLC 박막의 기계적 특성 분석)

  • Jeon, Young-Sook;Choi, Won-Seok;Hong, Byung-You
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.631-635
    • /
    • 2006
  • The properties of metal interlayered DLC films between the Si substrate and the DLC films were studied. DC magnetron sputtering method has been used to deposit intermediate layers of metals. And RF-PECVD method has been employed to synthesize DLC onto substrates of the silicon and metal layers. After we used metal Inter-layers, such as chromium, nickel, titanium and we studied tribological properties of the DLC films. The thickness of films were observed by field emission scanning electron microscope (FE-SEM). Also the surface morphology of the films were observed by an atomic force microscope (AFM). The crystallographic properties of the films were analyzed with X-ray diffraction (XRD), the friction coefficients were investigated by AFM in friction force microscope (FFM) mode. Tribological performances of the films were estimated by nano-indenter, stress tester measurement.

Plasma-mediated Hydrophobic Coating on a Silicate-based Yellow Phosphor for the Enhancement of Durability (플라즈마 소수성 코팅을 이용한 실리케이트계 황색형광체의 내구성 개선에 관한 연구)

  • Jang, Doo Il;Jo, Jin Oh;Ko, Ranyoung;Lee, Sang Baek;Mok, Young Sun
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.214-220
    • /
    • 2013
  • Hydrophobic coating on a silicate-based yellow phosphor ($Sr_2SiO_4:Eu^{2+}$) was carried out by using hexamethyldisiloxane (HMDSO) precursor in an atmospheric pressure dielectric barrier discharge plasma reactor, eventually to improve the long-term stability and reliability of the phosphor. The phosphor powder samples were characterized by a scanning electron microscope (SEM), a transmission electron microscope (TEM), a fluorescence spectrophotometer and a contact angle analyzer. After the coating was prepared, the contact angle of the phosphor powder increased to $133.0^{\circ}$ for water and to $140.5^{\circ}$ for glycerol, indicating that a hydrophobic layer was formed on its surface. The phosphor coated with HMDSO exhibited photoluminescence enhancement up to 7.8%. The SEM and TEM images of the phosphor powder revealed that the plasma coating led to a morphological change from grain-like structure to smooth surface with 31~46 nm thick hydrophobic layer. The light emitting diode (3528 1 chip LED) fabricated with the coated phosphor showed a substantial enhancement in the reliability under a special test condition at $85^{\circ}C$ and 85% relative humidity for 1,000 h (85/85 testing). The plasma-mediated method proposed in this work may be applicable to the formation of 3-dimensional coating layer on irregular-shaped phosphor powder, thereby improving the reliability.

Synthesis, Dispersion, and Tribological Characteristics of Alkyl Functionalized Graphene Oxide Nanosheets for Oil-based Lubricant Additives (액체 윤활제 첨가제용 알킬 기능화된 산화 그래핀의 합성/분산 및 트라이볼로지적 특성)

  • Choe, Jin-Yeong;Kim, Yong-Jae;Lee, Chang-Seop
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.533-540
    • /
    • 2018
  • Graphene has been reported to be an excellent lubricant additive that reduces friction and wear when coated on the surface of various materials or when dispersed in lubricants as an atomic thin material with the low surface energy. In this study, alkyl functionalized graphene oxide (FGO) nanosheets for oil-based lubricant additives were prepared by using three types of alkyl chloride chemicals (butyl chloride, octyl chloride, and tetradecyl chloride). The chemical and structural properties of the synthesized FGOs were analyzed by Fourier transform infrared (FT-IR), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscope (SEM), and transmission electron microscope (TEM). The synthesized FGOs were dispersed at 0.02 wt% in PAO-0W40 oil and its tribological characteristics were investigated using a high frequency friction/wear tester. The friction coefficient and the wear track width of poly alpha olefin (PAO) oil added with FGO-14 were tested by a ball-on-disk method, and the measured results were reduced by ~5.88 and ~3.8%, respectively compared with those of the conventional PAO oil. Thus, it was found that the wear resistance of PAO oil was improved. In this study, we demonstrated the successful functionalization of GO as well as the improvement of dispersion stability and tribological characteristics of FGOs based on various alkyl chain lengths.

Laser micromachining of micron-size aperture for electron beam microcolumn application using the piezo-switched Nd:YAG laser (Piezo Q-Switched Nd:YAG 레이저에 의한 초미니 전자빔 장치용 Micron-Size Aperture의 레이저 미세가공)

  • 안승준;김대욱;김호섭;최성수
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.456-460
    • /
    • 1999
  • Experimental studies of laser micromachining on Mo diaphragm using piezo Q-switched Nd:YAZ laser have been performed. Application of miniaturized micorcolumn electron gun arrays as a potential electron beam lithography or portable mini-scanning electron microscope (SEM) application have recently extensively examined. The conventional microcolumn fabrication technique would give a limitation on the minimization of aberration, In this paper, we obtained 20~30 $\mu \textrm m$aperture of laser micromachining on Mo diaphragm using piezo Q-swithed Nd:YAG laser. The geometrical figures, such as the diameter and the preciseness of the drilled aperture are dependent upon the total energy of the laser pulse train, laser pulse width, and the diameter of laser spot in addition to the materials-dependent parameters.

  • PDF

THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN (타액에 오염된 상아질에 대한 콤포머의 접합양상)

  • Cho, Young-Gon;Kim, Byung-Tae;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

Histological Changes of Tissues and Cell Wall of Rice Straw Influenced by Chemical Pretreatments

  • Wang, Jia-Kun;Chen, Xiao-Lian;Liu, Jian-Xin;Wu, Yue-Ming;Ye, Jun-An
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.6
    • /
    • pp.824-830
    • /
    • 2008
  • Sodium hydroxide (SH) or ammonium bicarbonate (AB) were applied to rice straw to investigate the effects on histological change of stem tissue or cell wall before and after in sacco degradation using a scanning electron microscope (SEM) and a transmission electron microscope (TEM). The SEM revealed that, the parenchyma and vascular bundles were distorted by treatment with SH at 30 or 45 g/kg straw dry matter. Faultage between phloem of large vascular bundles and parenchyma occurred with further increasing SH to 60 or 75 g/kg. The cell wall in these stem tissues was crimped when observed by TEM. However, only parenchyma and large vascular tissues were slightly distorted in AB-treated stem. For untreated and AB-treated stems, the initiation of observable ruminal degradation of cell wall was prolonged from 12 h for inner parenchyma to 24 h for sclerenchyma and to 48 h for phloem of small vascular bundles, while the outer epidermis was intact even at 72 h. For SH-treated stem, however, the cell wall from all of the investigated tissues, epidermis, small vascular bundles, sclerenchyma, and parenchyma started to be degraded at 12 h incubation. These results indicate that SH treatment contracts rice straw stem leading to an improvement in rumen degradation, and that the degradation of SH-treated stem is bilateral from inner and outer surface simultaneously.