• Title/Summary/Keyword: SE Measurement

Search Result 942, Processing Time 0.026 seconds

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

A Study on Improvement of Method for Measuring the Shield Performance of Shielding Enclosures (전자파 차폐실의 차폐효과 측정방법 개선에 관한 연구)

  • Yeon, Jae-Sung;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.350-353
    • /
    • 2009
  • The shielding enclosure is very essential device to test the electromagnetic wave power generated by various RF equipments. Some standards for the shielding enclosures were established to test them in right method. Generally, There are IEEE-STD-299 and MIL-STD-285 and NSA-65-6 of the method for measuring the effectiveness of shielding enclosures, the IEEE-STD-299 combined MIL-STD-285 and NSA-65-6 about the method for measuring shielding effectiveness(SE) about 1969 years, but, the measurement point of 299 proposal is many points(including shielding wall, seam, coner beat, shielding door, etc) and demand long time of measurement. To improve SE test method for shielding enclosures was studied and suggested to develop a proper test procedure. First, we measure reference level as frequency range and H/V polarization, secondly, measure leakage point, and finally, measure shield effect and calculate SE. Our method has a merit of the less measurement point than IEEE-STD-299, and shorten time than 299, and define representation SE of shielding enclosure effectively.

  • PDF

A Comparative Study on the Changes of Pelvic Alignment between AP View of the Pelvis in Standing and Supine Position (Pelvic AP X-ray 촬영 자세에 따른 골반변위 변화의 비교 연구)

  • Lee, Kyung-Moo;Park, Dong-Su;Kim, Soon-Joong;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.4
    • /
    • pp.161-169
    • /
    • 2008
  • Objectives : This study was carried out to investigate the relationship of pelvic alignment between AP view of the pelvis in standing and supine position. Methods : Sixteen healthy peoples who get $51.59{\pm}4.14$ as average in SF-36 were evaluated by X-ray findings. After measuring innomiate measurement, off centering measurement, sacral ala measurement, illium shadow measurement, the area of obturator foramen, those were analyzed statistically. Results : It was not all to be corresponded to distort pelvic alignment of AP view of the pelvis in standing and in supine. Sometimes it was the opposite result. Conclusions : These results suggest that the diagnosis of pelvic alignment to go through on each position is brought about disagreement with each other.

Fabrication and Characteristics of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ Heterojunction Solar Cell ($n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ Heterojunction 태양전지의 제작과 특성)

  • Baek, Seung-Nam;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.51-55
    • /
    • 2004
  • $CdS_{0.69}Se_{0.31}$ single crystal grown by sublimation method. Hall effect measurement were carried out by the Van der Pauw method. The measurement values under the temperature were found to be carrier density $n=1.95{\times}10^{23}m^{-3}$, Hall coeffcient $RH=3.21{\times}10^{-5}m^3/c$, conductivity ${\sigma}=362.41{\Omega}^{-1}m^{-1}$, and Hall mobility ${\mu}=1.16{\times}10^{-2}m^2/v.s.$ Heterojunction solar cells of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ were fabricated by the substitution reaction. The open-circuit voltage, short-circuit currint density, fill factor and power conversion efficiency of $n-CdS_{0.69}Se_{0.31}/p-Cu_{2-x}S_{0.69}Se_{0.31}$ heterojunction solar cell under $80mW/cm^2$ illumination were found to be 0.41V, $19.5mA/cm^2$, 0.75 and 9.99%, respectivity.

  • PDF

A Comparative Study on the Determination of the Selenium in Biological Samples using 75Se and 77mSe Nuclides (75Se과 77mSe 핵종을 이용한 생물시료 중의 셀렌 분석에 대한 비교 연구)

  • Moon, Jong-Hwa;Kang, Sang-Hoon;Kim, Sun-Ha;Chung, Yong-Sam;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.23-26
    • /
    • 2005
  • Se is well known as an anti-oxidant trace element and many customers are interested in an analysis and contents of Se in the various foodstuff samples. This study was aimed at establishig and comparing an analytical method for the determination of the Se in biological samples by neutron activation analysis using two nuclides, $^{75}Se$ and $^{77m}Se$. Keeping this objective, three NIST biological standard reference materials were chosen and the concentrations of the Se were determined under the prefixed analytical conditions such as the irradiation, decay and measurement time. The measured values by both analytical methods were evaluated with certified values. In addition, the detection limits and measurement uncertainty for the analytical results using $^{75}Se$ and $^{77m}Se$ were compared with each other.

Measurement of Drifting Mobility and Transit Time of Holes and Electrons in Stabilized a-Se Film

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.362-363
    • /
    • 2007
  • The transport property of stabilized amorphous selenium typical of the material used in direct conversion x-ray imaging devices was studied using the moving photo-carrier grating (MPG) technique and time-of-flight (TOF) measurements. For MPG measurement, the electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. For TOF measurement, a laser beam with pulse duration of 5ns and wavelength of 350 nm was illuminated on the surface of a-Se with thickness of $400{\mu}m$.

  • PDF

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

Growth and Photoluminescience Properties for $AgGaSe_2$ Single Crystal Thin Films ($AgGaSe_2$ 단결정 박막 성장과 광발광 특성)

  • Hong, Kwang-Joon;Yun, Seuk-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.159-160
    • /
    • 2006
  • $AgGaSe_2$ single crystal thin films grown by using hot wall epitaxy (HWE) system. The single crystal thin films were investigated by photoluminescence and double crystal X-ray diffraction(DCXD) measurement. From the photoluminescence measurement of $AgGaSe_2$ single crystal thin film, we observed free excition ($E_x$) observable only in high quality crystal and neutral bound exciton ($D^{\circ}$,X) having very strong peak intensity. And, the full width at hall maximum and binding energy of neutral donor bound excition were 8 meV and 14.1 meV, respectively. By Haynes rule, an activation energy of impurity was 141 meV.

  • PDF

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer (3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구)

  • Chang, Seok-Woo;Kwon, Ho-Beom;Yoo, Hyun-Mi;Park, Dong-Sung;Oh, Tae-Seok;Bae, Kwang-Shik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

Growth and Optical Properties for $AgGaSe_2$ Single Crystal Thin Films by Hot Wall Epitaxy (Hot Wall Epitaxy (HWE)법에 의한$AgGaSe_2$ 단결정 박막 성장과 광학적 특성)

  • Hong, Kwang-Joon;Back, Seoung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.124-127
    • /
    • 2003
  • The stochiometric $AgGaSe_2$ polycrystalline mixture of evaporating materials for the $AgGaSe_2$ single crystal thin film was prepared from horizontal furnance. To obtain the single crystal thin films, $AgGaSe_2$ mixed crystal and semi-insulating GaAs(100) wafer were used as source material and substrate for the Hot Wall Epitaxy (HWE) system, respectively. The source and substrate temperature were fixed at $630^{\circ}C$ and $420^{\circ}C$, respectively. The thickness of grown single crystal thin films is $2.1{\mu}m$. The single crystal thin films were investigated by photoluminescence and double crystal X-ray diffraction(DCXD) measurement. From the photoluminescence measurement of $AgGaSe_2$ single crystal thin film, we observed free excition ($E_x$) observable only in high quality crystal and neutral bound excition ($D^{\circ}$,X) having very strong peak intensity. And, the full width at half maximum and binding energy of neutral donor bound excition were 8 meV and 14.1 meV, respectively. By Haynes rule, an activation energy of impurity was 141 meV.

  • PDF