• Title/Summary/Keyword: SCREEN TEST

Search Result 627, Processing Time 0.023 seconds

Quality Control and Image Quality Comparison according to Ultrasonic Equipment (초음파 장비에 따른 정도관리와 화질 비교)

  • Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.935-942
    • /
    • 2022
  • In doing interventional treatment under the guidance of ultrasonography, the medical team detects the legion site with ultrasonic equipment at first, and insert angio needle. In this situation, if the position of legion and the depth of inserted needle on the ultrasonographic screen are different from real position and depth, the needle is likely to damage a major blood vessel or tissue. Accordingly, we had wondered how much such differences between screen image and reality, and so decided to examine them. Using five ultrasonographic equipments manufactured from different companies in different years, this study tried to compare the lengths of the needle on the screen images and real lengths of it, and find out the factors affecting skewness of them. This study used hog meat chunk to mimic human flesh, and sausages as the target of needle. It compared penetrating depths of the needle as the images on the five equipments using single sample t test in the SPSS 22 statistical program. It was found that all the errors were statistically significant(<.05). So, this study decided that it was wrong to evaluate performances of the equipments by the makers and ages of them. It is necessary to do periodic quality controls of equipments and improve the skillfulness of sonographers to reduce error rates between real treatment areas and the images of them.

Interface Development for the Point-of-care device based on SOPC

  • Son, Hong-Bum;Song, Sung-Gun;Jung, Jae-Wook;Lee, Chang-Su;Park, Seong-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This paper describes the development of the sensor interface and driver program for a point of care (POC) device. The proposed pac device comprises an ARM9 embedded processor and eight-channel sensor input to measure various bio-signals. It features a user-friendly interface using a full-color TFT-LCD and touch-screen, and a bluetooth wireless communication module. The proposed device is based on the system on a programmable chip (SOPC). We use Altera's Excalibur device, which has an ARM9 and FPGA area on a chip, as a test bed for the development of interface hardware and driver software.

Off-line Visual Feedback Control of SCARA Robot Using Off Line Programming (오프라인 프로그래밍을 이용한 스카라 로봇의 비쥬얼 피드백제어)

  • 신행봉;이우송;이현철;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.235-240
    • /
    • 2004
  • The equipment of industrial robot in manufacturing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using OLPS. A proposed visual calibration scheme is based on position-based visual feedback. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test and construction of simple silhouette figures. Then camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not require the precise calculation of tree-dimensional object data and image Jacobian.

  • PDF

Studies on Toxic Components of Auricularia polytricha (털목이버섯의 독성(毒性)에 관한 연구(硏究))

  • Kim, Ha-Won
    • Korean Journal of Pharmacognosy
    • /
    • v.16 no.4
    • /
    • pp.221-226
    • /
    • 1985
  • To screen biologically active components of the higher fungi of Korea, the dried carpophores of Auricularia polytricha were extracted with water. The extract was examined for acute toxicity in ICR mice. A low molecular weight toxin of this fungus was purified by acetone precipitation followed by cellulose, silica gel and LH-20 Sephadex column chromatography. Major symptoms of this toxin were eye extrusion, hair erection, trembling of head, paralysis, rapid running or moving before death and depression of respiration. The median lethal doses of the total extract were 1.25 g/kg and 4.18 g/kg by i.p. and p.o. administrations, respectively. The amounts of one mouse lethal unit (MLU) of the total extract and final fraction that killed a 20-g mouse within 30 minutes were 28.5 mg/mouse and 12 mg/mouse, respectively.

  • PDF

Analysis of Microphonic Phenomenon for Shadow Mask in Flat TV by FEM (유한요소법에 의한 평면 TV 새도우마스크의 마이크로포닉 현상 해석)

  • Kim, Jung;Park, Soog-Kil;Kang, Bum-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.89-95
    • /
    • 2002
  • A shadow mask inside the Braun tube of a TV is sustained by springs attached to the glass panel, its vibration cause the picture image to discolor, which is called the microphonic phenomenon. It is found that it results from resonance when the natural frequency of the shadow mask coincides with that of built-in speaker sound. This paper describes experimental and analytical investigations by using FEM on the vibration problem of the shadow mask assembly. The simulation scheme may be efficiently used to develop a new design for a large-screen flat TV.

Development of an Expert System for Steam Generator Tube Inspection of Nuclear Power Plants (원전설비 결함진단을 위한 전문가시스템 개발)

  • Woo, Hee-Gon;Choe, Seong-Su;Choi, Byung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.730-733
    • /
    • 1991
  • The inspection for steam generator tubes of nuclear power plants is performed by eddy current test method. In the current, human experts should check enormous amounts of eddy current(EC) signals to find abnormal ones on the computer screen. This method could cause a few problems. The purpose of this paper is to develop an expert system which can automatically evaluate EC signals of steam generator tubes. Since this expert system can replace or help human experts, the reliability in EC signal evaluation can be improved, and the required man-power can be reduced. Additionally, application of this system can shorten the overhaul period, contribute to a safe operation of the nuclear power plant.

  • PDF

Effects of Edible Herbs on the Growth of In Vitro Intestinal Microorganisms (산채류가 장내세균의 In Vitro 생육에 미치는 영향)

  • 한복진
    • Journal of Nutrition and Health
    • /
    • v.27 no.7
    • /
    • pp.717-728
    • /
    • 1994
  • This study was aimed to screen edible herbs which control the composition of intestinal microflora. With in vitro experiments, we screened the water or ethanol extracts of about 60 edible herbs and wild plants in terms of the inhibition activity on the growth of the harmful Clostridium perfringens and growth promoting activity for the beneficial Bifidobacteria. The water extracts of mugwort and small water dropwort inhibited the growth of Cl.perfringens both in agar diffusion method and broth culture. On the other hand, the water extracts of petasites, mugwort, yellow day-lily and bitter cress have shown the promotion effect on the growth of Bifidobacterium longum. In the culture test using human feces as starter, the extracts of the above selected herbs increased the population of Bifidobacteria and Lactobacillus while they reduced the numbers of Cl.perfringens and E.coli.

  • PDF

Carbon and Silver Electrode Properties of Power Electroluminescent Device (후막 전계 발광 소자의 Carbon과 Silver 전극 특성)

  • Lee, Jong-Chan;Sung, Hyun-Ho;Cho, Whang-Sin;Park, Yong-Kyu;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.26-30
    • /
    • 2000
  • In this paper, carbon and silver electrode properties of power electroluminescent device were investigated. Devices were manufactured by screen-printing and manufactured devices were measured following things with variable applied voltage; emission spectra, transferred charge density, brightness and current. A continuous test at $65 ^{\circ}C$ of temperature and 95% of humidity was operated. The brightness of devices which were made of silver and carbon electrode at 100V was $67.03cd/m^2$ and $60.02cd/m^2$ respectively. In case of device, which was made of silver electrode, a black spot was formed after 72 hours and degraded but carbon electrode was stable.

  • PDF

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

Measurement of Surface Heat Transfer Using Exponential Temperature Variations (지수형 온도변화를 이용한 표면 열전달의 측정)

  • Park, Byung Kyu;Hong, Taek;Park, Sang Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1121-1128
    • /
    • 1999
  • A single blow, transient testing method for determining the heat transfer characteristics of heat exchanger surfaces are presented. The exponential inlet temperature variations were made using screen mesh with small time constant and frontal velocities of the test section. The system is used to investigate the usefulness of a model with exponential inlet temperature variations. A data reduction program is developed to calculate the temporally and spatially averaged heat transfer coefficient using the measured disturbance and response of the fluid temperature. The results are compared with the existing theoretical and experimental data for parallel plate stacks. It was recommended to take an average for the time greater than the 99% of the final temperature had reached in order to obtain fairly good results.