• Title/Summary/Keyword: SCREEN TEST

Search Result 629, Processing Time 0.026 seconds

Relationship between Some Obesity Indices and Coronary Artery Stenosis in Health-Screen Examinees (건강검진 수검자에서 비만 지표들과 관상동맥협착증과의 관련성)

  • Eo, Jaeeun;Shin, Saeron
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.125-135
    • /
    • 2020
  • Purpose : Obesity indices are major predictive markers for coronary artery stenosis, but there are few studies about the relationship between obesity indices and coronary artery stenosis in the Korean population. Therefore, we analyzed the association between obesity indices and coronary artery stenosis among health-screen examinees. Methods : This study included 99 males and females who visited a health-examination center. The obesity indices included body mass index (BMI), waist circumference (WC), visceral adipose tissue (VAT), visceral adipose tissue/subcutaneous adipose tissue ratio (V/S ratio). All subjects had their degree of coronary artery stenosis measured using coronary computed tomography angiography (CCTA). A multiple logistic regression test was conducted to analyze the association between obesity indices and coronary artery stenosis. Results : This study was taken by multiple logistic regression test adjusted by age, sex, smoking status, frequency of alcohol drinking/week and frequency of exercise/week. The adjusted odds ratio for the presence of coronary artery stenosis for subjects with abdominal obesity (abdominal obesity defined as a waist circumference ≥ 90 cm in males; ≥ 85 cm in females) was 6.263 (95 % confidence interval (CI) 1.974-19.869), for subjects with visceral obesity by visceral adipose tissue (visceral obesity defined as a visceral adipose tissue ≥ 100) was 11.430 (95 % CI 3.044-42.928). Conclusion : In this study of adults, WC and VAT were independent predictors of coronary artery stenosis. These results suggest that WC and VAT may be useful markers of coronary artery stenosis.

Effects of Therapeutic Exercise on Hip Joint Range of Motion, Manual Muscle Test, Functional Movement Screen and Radiological Evaluation in a Youth Football Player with Football-specific Anterior Pelvic Tilt: A Case Report (치료적 운동이 축구 특이적 골반 앞 기울임을 가진 유소년 축구선수 엉덩관절의 관절가동범위, 도수근력, 기능적 움직임 및 방사선학적 평가에 미치는 영향: 증례보고)

  • Yu, Dong-Hun;Seo, Sang-Won;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.85-94
    • /
    • 2018
  • PURPOSE: This study was conducted to determine the effects of therapeutic exercise on range of motion (ROM), the manual muscle test (MMT), functional movement screen (FMS) and radiological evaluation in a youth football player with football-specific anterior pelvic tilt (APT). METHODS: The subject of this case report was a 12-year-old youth football player, who presented with football-specific APT. Therapeutic exercise consisted of hamstring stretch, prone hip extension, abdominal crunch, bridging with isometric hip abduction, plank exercise with posterior tilt and posterior pelvic tilting exercise using a swiss-ball for 40 min/day, twice a week for 8-weeks. ROM, MMT, FMS (deep squat, hurdle step, inline lunge, shoulder mobility, active straight-leg raise, rotary stability and trunk stability push-up) and radiographs (lumbar lordotic and sacral horizontal angle) were analyzed before and after week 8 of therapeutic exercise. RESULTS: The ROM, MMT, and FMS increased and the lumbar lordotic angle and sacral horizontal angle improved after 8-weeks of therapeutic exercise. CONCLUSION: The results of this case report suggest that therapeutic exercise improves ROM, MMT and radiography associated parameters in youth football players with football-specific APT. These findings have clinical implications for therapeutic exercise in youth football players with football-specific APT.

Study of the Usefulness of Tiltable standing detector in Testing Shoulder Joint Superoinferior axial (견관절 Superoinferior axial 검사 시 Tiltable standing detector의 유용성에 관한 고찰)

  • Lee, Dong-Hee;Kim, Byung-Ki;Kim, Ki-Jung;Kim, Min-Hyun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, we compared the alteration of test positions according to various test equipments when testing shoulder joint superoinferior axial to estimate the clinical usefulness of tiltable standing detector. Our objectives were patients who visited our hospital. Among them we chose patients who were prescribed to get a shoulder axial test, again we selected 30 patients whose abduction is more than 90 degree.(2008. Nov.$\sim$2009 Jan.) With the patients cooperation, we used CR(Agfa, Belgium), fixed-detector(Canon, japan), Tiltable-detector(Philips, Netherlands). Tested with only one equipment(tiltable detector), and posed with the other two. We surveyed 5 inspectors and 30 patients, asking them to rate the convenience of test position. Also, we checked how long it takes to have the image appear on screen after testing with the equipment We provided a standard for an assessment of the image to an expert in bone radiology, an orthopedist and a radiologist with 5 years experience. When the patients were asked about the convenience of the equipments, 15 people(50%) answered CR is convenient and 14 people(46.7%) answered the Tilting detector is convenient, showing not much difference. However, when the inspectors were asked the same question, 4people(80%) out of 5 answered that the Tilting detector is more convenient The time test showed that CR takes 2 minutes and 50 seconds, the Fixed detector 1minute and 48 seconds andor had no distortion showing the shoulder joint space. However, even though the Fixed detector showed ac the Tilting detector takes 1 minute and 43 seconds to bring the image to the screen after the position. The results of the value of image taken by each equipment, CR and the Tilting detectromion, coracoid process, due to the unstable pose, they were quite distorted and scored poor in observing glenoid fossa. By this study, we can see that testing the shoulder joint superoinferior axial projection with a detector that has a tilting device would be more convenient than testing it with a CR.

  • PDF

Effects of Kettlebell Training on Functional Movement Screen and Balance in Middle School Baseball Players (케틀벨 훈련이 중학교 야구선수의 기능적 움직임(Functional Movememt Screen)과 균형성에 미치는 영향)

  • Kim, Tae-Yoon;Park, Woo-Young;Byun, Yong-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.96-107
    • /
    • 2022
  • The purpose of this study was to demonstrate the effects of 8weeks Kettlebell training on the FMS and Balance in Middle school baseball player. Fourteen middle school baseball players were randomly assigned to a kettlebell group (n=8) and a control group (n=6), and kettlebell training was applied twice a week for 60 minutes. And the FMS, Y-balance test and static and dynamic balance test using smart shoes were tested before and after kettlebell training. Repeated two-way ANOVA measures was performed both before and after the exercise to verify the effect of kettlebell training. Also, if there was an interaction between time and group, a paired sample t-test was performed for each group. As a results of the study, FMS score showed a significant difference in IL (Inline Lunge) and TS(Total Score), and there was no significant difference in other variables of FMS. The YBT score showed a significant difference in all YBT variables except for the left AT. And the balance test using smart shoes, there was no significant interaction effect between group and period in all variables. In conclusion, it was found that the application of kettlebell training in middle school baseball players had an effects on the FMS and YBT scores related to functional movement and functional balance, but it did not affect the static/dynamic balance test using smart shoes evaluated by the foot pressure method. It seems that the results of this study can be provided as basic data necessary for planning a training program for middle school baseball players.

A study on the recognition of the dashboard in forklift (지게차 계기판의 인지성 평가에 관한 연구)

  • Choi Jin-Bong;Yun Yong-Gu;Jeong Myeong-Cheol;Park Beom
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.219-225
    • /
    • 2006
  • This paper studies on the visibility of dashboard in forklift. As part of the real setting devised for this study, 1. Important evaluation by males experience in forklift driving, 2. Icon cognition experiment, 3. Gage cognition experiment, subjects were asked to estimate the important evaluation, sketched to icon and gage position on the screen. Subjective evaluations were carried out by semantic differential method, sketch method, sketch method, then analyzed by consistency test, frequency rate and T-test. I gather the results concerning the relationship between consistent answers and cognition rates of dashboard understand the conditions which create a desired instrument panel.

  • PDF

Human Figure Drawings by Children with Emotional and Behavioural Problems (유아의 문제행동 유·무에 따른 인물화검사 비교연구)

  • Park, Yeon Kyoung;Hwang, Hye Jung
    • Korean Journal of Child Studies
    • /
    • v.22 no.2
    • /
    • pp.347-360
    • /
    • 2001
  • In order to analyze the human figure drawings of children with emotional and behavioural problems, the Preschool Behaviour Checklist (McGuire & Richman, 1988) was administered to 300 6-year-old children from which 15 boys and 15 girls with emotional and behavioural problems and 15 boys and 15 girls without problems were selected for the target and comparison groups, respectively. Compared with children without emotional and behavioural problems, the human figure drawings of the disturbed children included immature eye drawings; immature liaison of body and arms or legs; no hair; strong and repeated lines; unbalanced arms and legs; unbalanced size of face, body, arms, and legs; and the size of the human figure less than a fifth of the sheet of paper. These results imply that the human figure drawing test is an efficient way to screen children's emotional and behavioural problems.

  • PDF

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

A Study on the Parallel Processing of the Object Generator in a Suface Combat System LBTS (수상함 전투체계 육상시험체계용 개체생성기 구현에 적합한 병렬처리기법에 관한 연구)

  • Kim, Chang-Jin;Oh, Gwang-Baek;Jung, Young-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.734-738
    • /
    • 2010
  • Object Generator is a software to provide simulation object data(aircraft, ship, submarine, missile, torpedo) for sumulators in LBTS(Land Based Test System). but there is a burden to the system, because Object generator needs to send many object's data, display objects in a tactical screen, show object's information in a list in 1 second. This paper suggests a parallel software structure taking a few factors(deadlock, dependency) into consideration. At last, the paper shows the performance of the parallel structure's software compared with the former structure's software.

Effects of longitudinal conduction on the performance of heat transfer surfaces (유동방향의 열전도가 전열면의 성능에 미치는 영향)

  • Park, Byung-Kyu;Hong, Taek;Park, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.561-569
    • /
    • 1999
  • The effects of longitudinal heat conduction on the performance of heat transfer surfaces are investigated by using a single-blow method. In the transient testing method for determining the heat transfer characteristics, exponential inlet temperature variations are made by using screen-mesh heater with small time constant and low frontal velocities of the test section, and the experimentally determined inlet temperature profile is used as the inlet fluid temperature condition. The effects of longitudinal heat conduction are negligible only if $\gamma^\act<0.05\;and \;N_{tu}\le3$ and should be considered if $N_{tu}\le3$ The test results ate compared with the existing theoretical and experimental data and the validity of this technique is confirmed by the good agreement.

  • PDF