• 제목/요약/키워드: SCADA data

검색결과 207건 처리시간 0.029초

원격 감시 제어시스템에서 키 관리 방안 연구 (Research on key management for supervisory control and data acquisition system)

  • 이건직
    • 디지털산업정보학회논문지
    • /
    • 제16권4호
    • /
    • pp.29-42
    • /
    • 2020
  • SCADA (Supervisory Control and Data Acquisition) systems for remote monitoring, data acquisition and control are applied to major industrial infrastructures including power, water and railroad. Recently, there are many researches on key management scheme for secure communication due to change to the open network environment. These systems are located at far distances and are connected to the main control center through various types of communication methods. Due to the nature of these systems, they are becoming the significant targets of cyber attack. We propose an efficient key management scheme which is established on ID-based cryptosystem without an expensive computation on MTU (Master Terminal Unit), Sub-MTU, and RTU (Remote Terminal Unit). The proposed method is secure and effective in key management among multiple legitimate devices.

풍력발전기 증속기 상태를 감시하기 위한 SaaS 클라우드 인프라 개발 (Development of SaaS cloud infrastructure to monitor conditions of wind turbine gearbox)

  • 이광세;최정철;강승진;박사일;이진재
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.316-325
    • /
    • 2018
  • 본 논문에서, 풍력발전기 운영관리 및 유지보수 비용을 저감하기 위해, 분산되는 전산자원을 통합하고 인적 자원을 효율적으로 운영 할 목적으로 SaaS 클라우드 방식의 상태 감시 인프라를 설계 및 개발하였다. 개발한 인프라에서 관련 업무 및 서비스에 따라 각 데이터들을 계층화 하였다. 인프라 상에서 상태 감시를 수행 할 경우에 필요한 기본적인 SW를 개발하였다. 측정 시스템에 대응하는 데이터베이스 설계 SW, 현장 측정 SW, 데이터 전송 SW, 모니터링 SW로 구성되어 있다. 기존의 SCADA 데이터 뿐 아니라 추가적인 센서를 설치하여 풍력발전기의 상태 관측이 가능하다. 상태감시 알고리즘 내 단계 별 지연 시간을 모델링하여, 현장 측정에서 최종 모니터링 단계 까지 소요되는 총 지연 시간을 정의 하였다. 진동 데이터는 고해상도 측정에 의해 취득되기 때문에, 지연 시간은 불가피하고 유지보수에 관한 프로그램 운영 시 지연시간 분석은 필수적이다. 모니터링 대상은 MW 용량의 풍력발전기의 증속기이며, 해당 풍력발전기는 운전 한 지 10년이 넘는 모델로서, 이는 앞으로 해당 풍력발전기의 효율적인 유지보수를 위해 정확한 상태 감시가 필수적임을 뜻한다. 본 인프라는 연간 50TB 용량의 고해상도 풍력발전기 증속기 상태를 처리 할 수 있도록 운영 중이다.

Fuzzy Petri-net Approach to Fault Diagnosis in Power Systems Using the Time Sequence Information of Protection System

  • Roh, Myong-Gyun;Hong, Sang-Eun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1727-1731
    • /
    • 2003
  • In this paper we proposed backward fuzzy Petri-net to diagnoses faults in power systems by using the time sequence information of protection system. As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. The fuzzy Petri-net models of protection system are composed of the operating process of protective devices and the fault diagnosis process. Fault diagnosis model, which makes use of the nature of fuzzy Petri-net, is developed to overcome the drawbacks of methods that depend on operator knowledge. The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method covers online processing of real-time data from SCADA (Supervisory Control and Data Acquisition)

  • PDF

Optimizing Performance of Wind Turbines

  • Kusiak, Andrew
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2009
  • Variable loads along the drive-train are attributed to frequent failures of gears, bearings, and other components. Wind parameters cannot be controlled and therefore any turbine load-reducing remedies must be established based on proper insights into the wind-turbine interactions. A novel control concept to performance optimization of wind turbines is presented. This proposed concept is based on analysis of the turbine status reflected in the SCADA data. Modern computational techniques are used to optimize performance of a wind turbine from tree basic perspectives: drive-train, power output, and power quality. The proposed approach demonstrates that gains in the metrics representing the three perspectives and the corresponding control goals can be significantly improved for any wind turbine. The solution is applicable different turbine types operating in different wind regimes, e.g., winds of different speeds and variability. Simple and transparent parameters allow an operator to determine a balance between the operations and maintenance, technical, business objectives. The proposed modeling framework was embedded in software. The software tool has been tested on the data collected from 1.5 MW wind turbines.

  • PDF

퍼지 페트리네트를 이용한 전력계통 고장진단에 관한 연구 (A Study on Fault Diagnosis of Power System Using Fuzzy Petri Nets)

  • 노명균;홍상은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.122-124
    • /
    • 2000
  • As the complexity of power systems increases, especially in the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires new and systematic methods to the reasoning process, which improves both its accuracy and its efficiency. Therefore this paper proposes a method of the modeling of protection systems and fault diagnosis in power systems using Fuzzy Petri Nets (FPN). The proposed method can reduce processing time and increase accuracy when compared with the traditional methods. And also this method can cover online processing of real-time data from SCADA (Supervisory Control and Data Acquisition).

  • PDF

Improving a Forward & Backward Secure Key Management Scheme for Wireless Sensor Networks

  • Park, Dong-Gook
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.521-524
    • /
    • 2009
  • Park proposed a forward & backward Secure key management scheme in wireless sensor networks for Process Control Systems (PCSs) or Supervisory Control and Data Acquisition (SCADA) systems [7]. The scheme, however, is still vulnerable to an attack called "sandwich attack": two nodes captured at times $t_1$ and $t_2$, respectively, surrenders all the group keys used between times $t_1$ and $t_2$. In this paper, we propose a fix to the scheme, which can limit the vulnerable time duration to an arbitrarily chosen time span while keeping the forward and backward secrecy of the scheme untouched.

Sensors Network and Security and Multimedia Enhancement

  • Woo, Seon-mi;Lee, Malrey
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제8권1호
    • /
    • pp.64-68
    • /
    • 2016
  • These fields are integrated to visualize and finalize the proposed development, in simulation environment. SCADA (supervisory control and data acquisition) systems and distributed control systems (DCSs) are widely deployed in all over the world, which are designed to control the industrial infrastructures, in real ways. To supervise and control the various parts of designed systems; trends to require a deep knowledge to understand the overall functional needs of industries, which could be a big challenge. Industrial field devices (or network sensors) are usually distributed in many locations and are controlled from centralized site (or main control center); the communication provides various signs of security issues. To handle these issues, the research contribution will twofold: a method using cryptography is deployed in critical systems for security purposes and overall transmission is controlled from main controller site. At controller site, multimedia components are employed to control the overall transmission graphically, such as system communication, bytes flows, security embedded parameters and others, by the means of multimedia technology.

대규모 배전자동화 시스템의 데이터베이스 구축을 위한 시스템 연계 연구 (The study of linkage between systems to make the database of distribution automation system)

  • 하복남;강문호;조남훈;정창수;김재성;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.419-421
    • /
    • 2001
  • The large distribution automation system for metropolitan city was developed in KEPCO just recently. This system has many functions for remote control and data acquisition, and it will be linked the other computer aided system such as NDIS(new distribution automation system) and SCADA(supervisory control and data acquisition) to construct the database of DAS(distribution automation system).

  • PDF

스마트 그리드 망을 위한 IEC61970/IEC61850 통합 정보 모델과 토폴로지 모델 설계 (Designs of the Unified Information Model-IEC61850/IEC61970 and Topology Model for Smart Grid)

  • 윤석열;임화영
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.28-33
    • /
    • 2012
  • The smart grid, which is an integrated type of the power system and the digital network, requires the integration of a CIM(Common Information Model) standard for information modelling at the power control centers and an IEC 61850 standard for automation at the substation level in order to efficiently exchange the information between system elements. This paper describes the method of data transfer from one standard information model to the other standard unified information model by mapping between the objects of IEC 61850 and IEC61970 CIM standards both in the static and dynamic models, and designs the method of data transfer and information exchange between the topology processing application using unified topology class packages.

Information and Communication Technologies for Smart Water Grid Applications

  • Ballhysa, Nobel;Choi, Gyewoon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • 제8권2호
    • /
    • pp.218-226
    • /
    • 2019
  • The use of Information and Communication Technologies (ICT) is the key to operate a change from the traditional manual reading of water meters and sensors to an automated system where high frequency data is remotely collected and analyzed in real time, one of the main components of a Smart Water Grid. The recent boom of ICT offers a wide range of both wired and wireless technologies to achieve this objective. We review and present in this article the most widely recognized technologies and protocols along with their respective advantages, drawbacks and applicability range which can be Home Area Network (HAN), Building Area Network (BAN) or Local/Neighborhood Area Network (LAN/NAN). We also present our findings and we give recommendations on the application of ICT in Smart Water Grids and future work needed.