• Title/Summary/Keyword: SAg

Search Result 702, Processing Time 0.036 seconds

A Study on Voltage Sag Considering Real-Time Traffic Volume of Electric Vehicles in South Korea

  • Go, Hyo-Sang;Kim, Doo-Ung;Kim, Jun-Hyeok;Lee, Soon-Jeong;Kim, Seul-Ki;Kim, Eung-Sang;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1492-1501
    • /
    • 2015
  • This paper analyzes the effect of voltage sag on distribution systems due to the connection of Electric Vehicles (EVs). In order to study the impact of the voltage sag on the power system, two scenarios have been selected in this paper. The distribution system and EVs are modeled using the Electro Magnetic Transients Program (EMTP). The numbers of EVs are predicted based on the number of vehicles in distribution system of Seoul. In addition, the number of EVs is set up using real-time traffic in Seoul to simulate Scenario I and II. The simulation results show that voltage sag can occur if the distribution system has more than 30% of the total number of vehicles.

Assessing the Effect of Voltage Sag in Distribution System Using a Fuzzy Risk Assessment Model (퍼지 위험도 평가 모델을 이용한 배전계통의 순간전압강하 영향 평가)

  • Yun, Sang-Yun;Oh, Jung-Hwan;Han, Byung-Duk;Kim, Jae-Chul;Park, Joong-Shin;Lim, Dong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1085-1087
    • /
    • 1999
  • In this paper, we propose the method for assessing the effect of voltage sag in power distribution system using fuzzy risk assessment model. The proposed method is based on SCBEMA curve that expresses the representative susceptibility curve by voltage sag for each customer type. These corves are made using the CBEMA curves obtained from the experiment for the customers'sensitive equipment. In order to transform SCBEMA curves to the probability damage by voltage sag, the fuzzy risk assessment model is used in this paper. Case studies were performed to analyze the effect of voltage sag by varying parameters. The Monte Carlo simulation method and the historical reliability data in KEPCO are used for case studies.

  • PDF

The Effects of Elastic Modulus Coefficient and Linear Expansion Coefficient of Overhead Conductor on Sag Behavior (가공전선의 이도거동에서 탄성계수와 선팽창계수의 영향)

  • Kim, Byung-Geol;Kim, Shang-Shu;Wang, Yun-Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.954-960
    • /
    • 2008
  • The effects of elastic modulus coefficient and linear expansion coefficient of overhead distribution power line(ACSR $58 mm^2$) on sag behavior in distribution line have been investigated to clarify the difference between specification and experimental level. The elastic modulus coefficients of Al wire and steel wire were $5,182.6 kgf/mm^2,\;18,348.8 kgf/mm^2$, respectively Therefore, the computational composition elastic modulus coefficient of the power line was $7,063.5 kgf/mm^2$, while that of experimentally measured was $7681.1 kgf/mm^2$. As a result, we found that elastic modulus coefficient which was experimentally measured was higher than that of computational by 8.7 %. However, when planner designs the sag of disoibution line, the elastic modulus coefficient of power line $8,400 kgf/mm^2$ should be generally adopted. These two different using values lead to the sag difference of 0.62 m. The other results will be discussed.

Modeling of Power Quality Stabilization using SMES and DVR (SMES 와 DVR을 이용한 전력계통품질 안정화 시스템 모델링)

  • Park, Sung-Yeol;Jung, Hee-Yeol;Kim, A-Rong;Kim, Jae-Ho;Park, Min-Won;Yu, In-Keun;Kim, Seok-Ho;Kim, Hae-Jong;Seong, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2251-2252
    • /
    • 2008
  • Recently, voltage sag from sudden increasing loads is also one of the major problems inside the utility network. In order to compensate the voltage sag problem, power compensation device systems could be a good solution method. In case of voltage sag, an energy source is needed to overcome the energy loss caused by the voltage sag. Superconducting Magnetic Energy Storage (SMES) is a very promising source of this energy due to its fast response of charging and discharging time. Before constructing the power electronic delivering system for the SMES, it is necessary to simulate the system to understand its behavior. Nowadays, a lot of devices have been developed to compensate voltage sag such as Dynamic Voltage Restorer (DVR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DVR system which will be simulated by using PSCAD/EMTDC software.

  • PDF

A Study on the Detection Algorithm of Voltage Sag using Wavelet Transform (Wavelet 변환을 이용한 voltage sag의 검출기법에 관한 연구)

  • Kim, C.H.;Lee, J.P.;Yeo, S.M.;Kang, Y.S.;Kang, J.S.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.276-278
    • /
    • 2001
  • In recent years, both electric utilities and end users have expressed their deep concerns about the quality of electric power. Especially, voltage sag which is one of power quality disturbance is very serious power quality problem on the power system. Voltage sag is a decrease to between 0.1 and 0.9 pu in rms voltage magnitude on the power system for durations from 0.5 cycles to 1 minute. These voltage sags are usually caused by fault conditions, overloads, and starting of large motors. The wavelet transform has attracted considerable attention in the field of power quality analysis recently. It has proved to be a powerful tool to study those transients that have time-localized information. In this paper, different types of voltage sags are simulated by using EMTP. This paper proposes the effective technique for voltage sag detection using wavelet transform.

  • PDF

Quantitative Evaluation of the Impact of Low-Voltage Loads due to Repetitive Voltage Sags

  • Yun Sang-Yun;Kim Jae-Chul;Moon Jong-Fil;Kang Bong-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.293-299
    • /
    • 2005
  • Automatic reclosing is a typical protection method in power distribution systems for the clearing of temporary faults. However, it has a fatal weakness in regards to voltage sags because it produces repetitive voltage sags. In this paper, we explored the repetitive impact of voltage sag due to the automatic reclosing of power distribution systems. The actual tests of low voltage loads were carried out for obtaining the susceptibility of voltage sags. The final results of the tests yielded power acceptability curves of voltage sag, and the curves transformed the 3-dimensional CBEMA (Computer Business Equipment Manufacturer Association) format. For the quantitative evaluation of the impact of repetitive voltage sags, an assessment formulation using the voltage sag contour was proposed. The proposed formulation was tested by using the voltage sag contour data of IEEE standard and the results of the test. Through the case studies, we verified that the proposed method can be effectively used to evaluate the actual impact of repetitive voltage sags.

A Single-Phase Quasi Z-Source Dynamic Voltage Restorer(DVR) (단상 Quasi Z-소스 동적전압보상기(DVR))

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • This paper deals with a single-phase dynamic voltage restorer(DVR) with a quasi Z-source topology. The proposed system based on a single-phase quasi Z-source PWM ac-ac converter which have features such as the input voltage and output voltage are sharing ground, and input current operates in continuous current mode(CCM). For the detection of voltage sag-swell, peak voltage detection method is applied. Also, the circuit principles of the proposed system are described. During the 60% severe voltage sag and 30% voltage swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Numerical Parametric Analysis of the Ultimate Loading-Capacity of Channel Purlins with Screw-Fastened Sheeting

  • Zhang, Yingying;Xue, Jigang;Song, Xiaoguang;Zhang, Qilin
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1801-1817
    • /
    • 2018
  • This paper presents the numerical parametric analysis on the loading capacity of Channel purlins with screw-fastened sheeting, in which the effects of anti-sag bar and corrugated steel sheet on the ultimate capacity are studied. Results show that the setup of anti-sag bars can reduce the deformations and improve the ultimate capacity of C purlins. The traditional method of setting the anti-sag bars in the middle of the web is favorable. The changing of sheeting type, sheeting thickness and rib spacing has significant effects on the ultimate capacity of C purlins without anti-sag bars, compared with those with anti-sag bars. The proposed design formulas are relatively consistent with the calculations of EN 1993-1-3:2006, which is different from those of GB 50018-2002.

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF

Optimal control of DSTATCOM for voltage sag compensation (EMTDC를 이용한 배전 선로 전압 보상을 위한 병렬 보상기의 최적 제어기 구현)

  • Jung, Soo-Young;Moon, Seung-Il;Kim, Tae-Hyun;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.320-322
    • /
    • 2001
  • 본 논문에서는 전압 sag보상을 하기 위한 DSTATCOM 제어기를 설계하고 EMTDC/PSCAD로 확인하였다. DSTATCOM의 전류성분을 d,q분해 해석을 통하여 상태방정식을 유도하고 부하모델과 네트워크의 제약조건을 결합 모델을 제시하였다. 1선 지락 사고시 PI 제어시보다 LQR 제어의 응답 특성이 우수함을 검증하고 전압 sag가 개선됨을 보였다.

  • PDF