• 제목/요약/키워드: SACP

검색결과 8건 처리시간 0.033초

溫度順應이 흰쥐의 血淸알칼리 및 酸性 Phosphatase 活性에 미치는 影響 (Effect of Temperature Acclimation on Activities of Serum Alkaline and Acid Phosphatases of the Rat)

  • Kim, Duk-Man
    • 한국동물학회지
    • /
    • 제18권4호
    • /
    • pp.173-180
    • /
    • 1975
  • Sprague-Dawley 系인 成熟한 雄性흰쥐를 對照群과 實驗群으로 나누어 對照群은 $23^\\circ C$에서 保存하였으며 實驗群은 $30^\\circ C 및 33^\\circ C$에서 各各 240時間 및 64時間동안 繼續하여 溫度順應시켰다. 溫熱順應의 各 時間區마다 血淸알칼리性 및 酸性 Phosphatase의 活性을 測定하였다. $30^\\circ C$에서는 上記 酵素活性의 變化相은 $33^\\circ C$에 比하여 一般的으로 顯著하였다. 다시 말하면 $30^\\circ C$에서의 溫熱順應에 있어서 血淸알칼리性 및 酸性 Phosphatase는 對照群에 比하여 一般的으로 높은 活性의 恒定特續性을 나타내었다. 以上의 結果로 미루어 보아 上記 酵素는 $30^\\circ C$의 溫熱順應에 있어서 生化學的으로 直接 또는 間接으로 溫度調節에 關與하고 있는 것으로 思料된다.

  • PDF

Study on the Influence of Stray current Between Sacrificial Anode Cathodic Protection and Impressed Current Cathodic Protection in Marine Environment

  • Jeong, Jin-A;Kim, Ki-Joon
    • Corrosion Science and Technology
    • /
    • 제11권3호
    • /
    • pp.77-81
    • /
    • 2012
  • Cathodic protection(CP) is widely used as a means of protecting corrosion for not only marine structures like ship hulls and offshore drilling facilities, but also underground structures like buried pipelines and oil storage tanks. The principle of CP is that the anodic dissolution of metal can be protected by supplying electrons to the cathode metal. When unprotected structures are nearby to CP systems, interference problems between unprotected and protected structures may be happened. The stray current interference can accelerate the corrosion of nearby structures. So far many efforts have been made to reduce the interference in the electric railway systems adjacent to the underground metal structures like buried pipelines and gas/oil tanks. During recent few decades the protection technologies against stray current induced corrosion have been significantly improved and a number of techniques have been developed. However, there is very limited information an marine environments. Some complex harbor structures are protected by two cathodic protection systems, i.e. sacrificial anode cathodic protection(SACP) and impressed current cathodic protection(ICCP). In this case, when the protection current from sacrificial anodes returns to the cathode through electrolyte, it passes through nearby other low resistance metal structures. In many cases the stray current of ICCP systems influences the function of SACP. In this study, the risk of stray current from the SACP system to adjacent reinforced concrete structures has been verified through laboratory experiments. Concrete and steel pile structures modeled a part of bridge have been investigated in terms of CP potential and current between the two. The variation of stray current according to the magnitude of ICCP/SACP has been studied to mitigate it and to suggest the proper protection criteria.

희생양극식 음극방식이 적용된 해안 교량 구조물의 방식거동 (Cathodic Protection Behavior of Coastal Bridge Structure with Sacrificial Anode Cathodic Protection System)

  • 하지명;진충국;정진아
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.242-246
    • /
    • 2012
  • This measurement represents the effectiveness of sacrificial anode cathodic protection (SACP) system in a coastal bridge structure. To verify the cathodic protection (CP) effect, the monitoring sensor (DMS-100) that could measure potential, corrosion rate, current, concrete resistivity, and temperature was embedded. The measurement conducted for three years after CP system was installed. Specifically, due to the fact that fresh water and sea water was repeated in the bridge structure, this bridge structure presented special CP behavior. Measurement factors were CP potential, CP current, concrete resistivity, and depolarization potential. In addition, visual inspection was also carried out. As a result of current and depolarization measurement, CP system was well activated in most piers.

TiO2 Combining Spherical Activated Carbon Photocatalysts and Their Physicochemical and Photocatalytic Activity

  • Oh, Won-Chun;Kim, Jong-Gyu;Kim, Hyuk;Chen, Ming-Liang;Zhang, Feng-Jun;Zhang, Kan;Choi, Jong-Geun;Meng, Ze-Da
    • 한국재료학회지
    • /
    • 제20권10호
    • /
    • pp.535-542
    • /
    • 2010
  • In this study, we used coal-based activated carbons and charcoal as startingmaterials, phenolic resin (PR) as a binder, and TOS as a titanium source to prepare $TiO_2$ combining spherical shaped activated carbon photocatalysts. The textural properties of the activated carbon photocatalysts (SACP) were characterized by specific surface area (BET), energy dispersive X-ray spectroscopy (XRD), scanning electron microscopy (SEM), iodine adsorption, strength intensity, and pressure drop. The photocatalytic activities of the SACPs were characterized by degradation of the organic dyes Methylene Blue (MB), Methylene Orange (MO), and Rhodamine B (Rh. B) and a chemical oxygen demand (COD) experiment. The surface properties are shown by SEM. The XRD patterns of the composites showed that the SACP composite contained a typical single, clear anatase phase. The EDX spectro for the elemental indentification showed the presence of C and O with Ti peaks. According to the results, the spherical activated carbon photocatalysts sample of AOP prepared with activated carbon formed the best spherical shape, a high BET surface area, iodine adsorption capability and strength value, and the lowest pressure drop, and the photocatalytic activity was better than samples prepared with charcoal. We compared the degradation effects among three kinds of dyes. MB solution degraded with the SACP is better than any other dye solutions.

A Study on the Effect of the ICCP System in Reinforced Concrete Specimens of Slab Type

  • Jeong, Jin-A;Ko, Kwon-Heum;Kim, Mun-Su;Lee, Du-Hyeong
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.272-278
    • /
    • 2018
  • Reinforced concrete (RC) has been used as a construction material in various environments, such as airports, bridges, and ocean concrete structures, etc. Over time, however, rebar in the concrete is prone to corrosion from environmental forces and structural defects of the concrete. Cathodic protection (CP) was invented to prevent problems with corrosion and is widely used for different applications. Cathodic protection is divided into two types: sacrificial anode cathodic protection (SACP) and impressed current cathodic protection (ICCP). There are several limitations to the use of sacrificial anode cathodic protection in complex reinforced concrete structures, including concrete resistivity, throwing power of the CP, and environmental conditions. These limitations can affect the protection performance of SACP. Therefore, we used impressed current cathodic protection in our study. We tested Ti-Mesh, Ti-Rod, and Ti-Ribbon anodes in slab type reinforced concrete specimens. Electrochemical tests were conducted to confirm the impressed current cathodic protection performance under different environmental conditions.

The effects of polymers and fly ash on unconfined compressive strength and freeze-thaw behavior of loose saturated sand

  • Arasan, Seracettin;Nasirpur, Omid
    • Geomechanics and Engineering
    • /
    • 제8권3호
    • /
    • pp.361-375
    • /
    • 2015
  • Constructions over soft and loose soils are one of the most frequent problems in many parts of the world. Cement and cement-lime mixture have been widely used for decades to improve the strength of these soils with the deep soil mixing method. In this study, to investigate the freeze-thaw effect of sand improved by polymers (i.e., styrene-acrylic-copolymer-SACP, polyvinyl acetate-PVAc and xanthan gum) and fly ash, unconfined compression tests were performed on specimens which were exposed to freeze-thaw cycles and on specimens which were not exposed to freeze-thaw cycles. The laboratory test results concluded that the unconfined compressive strength increased with the increase of polymer ratio and curing time, whereas, the changes on unconfined compressive strength with increase of freeze-thaw cycles were insignificant. The overall evaluation of results has revealed that polymers containing fly ash is a good promise and potential as a candidate for deep soil mixing application.

함정용 Al 및 Zn 희생양극의 효율에 미치는 첨가원소 영향 (Effect of Additional Elements on Efficiency of Al and Zn Sacrificial Anode for Naval Vessels)

  • 최우석;박경철;김병호
    • 한국항해항만학회지
    • /
    • 제39권4호
    • /
    • pp.277-283
    • /
    • 2015
  • 함정에 사용되는 선체재료로는 연강, 고장력강, 고강도강, 알루미늄 합금 및 복합재료 등이 있다. 그 중 함정의 선체는 수밀과 강도의 유지 및 탑재장비의 지지 등 기본적인 기능을 위하여 철강 재료를 주로 사용하고 있다. 함정의 주 임무는 해양에서 작전을 수행하는 것이므로 해수에 의한 선체 부식이 필연적으로 발생하게 된다. 선체의 부식을 방지하기 위하여 도장 방법, 희생양극법 및 강제 전류 방식이 사용되고 있다. 특히 Al 및 Zn을 활용한 희생양극법의 경우 부식특성 개선을 위하여 인듐(In), 카드뮴(Cd) 및 납(Pb) 등의 중금속이 첨가되어 있다. 하지만 이러한 중금속은 인체 및 환경에 매우 유해하므로 전 세계적으로 사용이 점차 규제되고 있다. 이에 본 논문에서는 인체 및 환경에 무해한 미세원소(Ma, Ca, Ce 및 Sn)를 첨가하여 Al 및 Zn 합금을 제조하였다. 제조된 함정용 Al 및 Zn 희생양극의 효율 특성 측정을 위하여 SEM, XRD, 동전위 분극실험 및 전류효율 평가를 실시하였으며, 실험결과 Al-3Zn-0.6Sn 및 Zn-3Sn 합금의 양극 성능이 다른 합금 보다 효율성이 우수하였다.