• Title/Summary/Keyword: S-Duct

Search Result 603, Processing Time 0.033 seconds

A Case of Lingual Thyroglossal Duct Cyst Treated by CO2 Laser via Transoral Approach (경구강 CO2 레이저를 이용하여 치료한 설갑상설관 낭종 1예)

  • Kim, Tae Hwan;Park, Jin Su;Lee, Sang Hyuk;Jin, Sung Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.2
    • /
    • pp.74-77
    • /
    • 2015
  • A lingual thyroglossal duct cyst(LTGDC) is a rare congenital anomaly that account for only 0.5% to 2% of total thyroglossal duct cyst. LTGDC is frequently associated with respiratory problem in infants and pharyngeal foreign body sensation or dysphagia in adults. Because of its location and characteristics, lingual thyroid, dermoid cyst, and vallecular cyst should be included in differential diagnosis. Standard treatment for thyroglossal duct cyst is sistrunk's operation, but in terms of LTGDC, because of its location and cosmetic reasons, different kinds of treatments such as electrical cauterization, $CO_2$ laser, Robort surgery via transoral approach have been introduced. Recently authors encountered 21 years old woman with LTGDC and the mass was removed successfully via transoral approach using $CO_2$ laser. We report the clinical course with review of the literature.

  • PDF

A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

Numerical Analysis of Three Dimensional Turbulent Flow in a HVAC Duct (HVAC 덕트내의 3차원 난류유동에 관한 수치해석적 연구)

  • 정수진;류수열;김태훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.118-129
    • /
    • 1996
  • In this study, three dimensional flow analysis in a HVAC duct was performed computationally using various turbulence models and compared numerical predictions such as outlet flow split, surface pressure distribution along the duct to experimental data. It's well known that accuracy of computational predictions of flow heavily dependent on turbulent models and discritization method. Therefore, in this work, to assess the ability of turbulent models to predict characteristics of duct flow, three kinds of models, namely standard $k-\varepsilon$, RNG $k-\varepsilon$ and modified $k-\varepsilon$, containing parameter for the effect of streamline curvature were employed and validated one another by comparing with experimental data. In results, modified $k-\varepsilon$ turbulence model allows a successful prediction of static pressure distribution particulary at around strong curvature but little improvement flow split. In the futrue, adoption of CFD to design HVAC duct with modified $k-\varepsilon$ model will bring benefits of producing more accurate prediction, and also give designers more detail information much more than now.

  • PDF

Bile Duct Obstruction Stimulates Lipid Peroxidation and Liver Fibrosis (Cirrhosis) in Rat (랫드에서 담도폐쇄에 의한 지질과산화와 간섬유화(경화) 촉진에 관한 연구)

  • 김기영;서의석;임진아
    • Toxicological Research
    • /
    • v.17 no.3
    • /
    • pp.187-194
    • /
    • 2001
  • The oxidative stress causes the cell damage and death and thereby, stimulates membrane lipid peroxidation. In this study, the correlation between the lipid peroxidation product and the parameter of liver fibrosis (cirrhosis) was investigated in cholestasis induced rats. The Sprague-Dawley rats were divided into 3 groups (sham: sham operation, BDL/S-I and BDL/S-II : bile duct ligation/scission) and were observed for 2 or 4 weeks. After observation period, the organs were weighed and the ratio of organ weight/body weight was calculated. Sera and liver tissue were used for the measurement of malondealdehyde (MDA), parameter of clinical biochemistry, total collagen content and the staining. The ratio of organ weight/body weight in BDL/S-I and BDL/S-II was significantly increased compared to sham operated group. Serological parameters (Alanine transaminase, Aspartate transaminase, Alkaline phosphatase and Total bilirubin) in BDL/S-I and BDL/S-II group were significantly higher than those in sham operated group. Concentration of MDA in BDL/S-I (261%) and BDL/S-II(790%) was significantly increased compared to MDA in sham operated group. And the content of hydroxyproline (hyp) in BDL/S-I and BDL/S-II group was significantly increased 2~4 times than in sham operated group. The good correlations between hyp in liver tissue and MDA in sera of sham operated group and all operated group were found (r=0.825). The significantly higher value of MDA, hyp and serological parameters in BDL/S-I and BDL/S-II group suggests the stimulation of lipid peroxidation and chronic liver damage. Especially the activation of lipid peroxidation and the stimulation of liver fibrosis was stronger in BDL/S-II group than in BDL/S-I group. The stronger fibrosis, portal-portal septum formation, the more massive bile duct proliferation in portal triads and stroma, and hepatocytes swelling were observed in liver tissue of and BDL/S-II group compared to BDL/S-I group. Conclusively, a good correlation between MDA as a lipid peroxidation marker and hyp as a liver fibrotic parameter could be connected with the process of liver fibrosis. Moreover, cholestasis condition may cause jaundice, activation of lipid peroxidation, and collagen accumulation in liver. Additionally, optimal observation period of bile duct obstruction for the screening of antioxidant and antifibrotic effect in rats would be four weeks.

  • PDF

OPTIMAL SHAPE DESIGN OF A S-SHAPED SUBSONIC INTAKE USING NURBS (NURBS를 이용한 S형 천음속 흡입관 최적 설계)

  • Lee B.J.;Kim C.
    • Journal of computational fluids engineering
    • /
    • v.11 no.1 s.32
    • /
    • pp.57-66
    • /
    • 2006
  • An optimal shape design approach is presented for a subsonic S-shaped intake using aerodynamic sensitivity analysis. Two-equation turbulence model is employed to capture strong counter vortices in the S-shaped duct more precisely. Sensitivity analysis is performed for the three-dimensional Navier-Stokes equations coupled with two-equation turbulence models using a discrete adjoint method For code validation, the result of the flow solver is compared with experiment data and other computational results of bench marking test. To study the influence oj turbulence models and grid refinement on the duct flow analysis, the results from several turbulence models are compared with one another and the minimum number of grid points, which can yield an accurate solution is investigated The adjoint variable code is validated by comparing the complex step derivative results. To realize a sufficient and flexible design space, NURBS equations are introduced as a geometric representation and a new grid modification technique, Least Square NURBS Grid Approximation is applied With the verified flow solver, the sensitivity analysis code and the geometric modification technique, the optimization of S-shaped intake is carried out and the enhancement of overall intake performance is achieved The designed S-shaped duct is tested in several off-design conditions to confirm the robustness of the current design approach. As a result, the capability and the efficiency of the present design tools are successfully demonstrated in three-dimensional highly turbulent internal flow design and off-design conditions.

A CASE REPORT OF SIALOLITHIASIS IN WHARTON'S DUCT (Wharton씨 도관내에 발생한 타석증에 관한 증례보고)

  • Lee, Kyung-Ok;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.603-609
    • /
    • 1997
  • Sialolithiasis is the formation of calcific concretions within the ductal system of major or minor salivary glands. The exact nature of sialolith evolution is not known. It may occur at any age but, it is most common in middle-aged adult and rare in childhood. In this paper, a case of sialolithiasis just beneath the mucosa in the anterior portion of the Wharton's duct observed in a 5-year old boy. It was approximately $2.5{\times}5$ mm in size and has no clinical symptoms. Under local anesthesia, it was removed by dilatation of orifice of the duct and pressure on the floor of oral cavity by finger.

  • PDF

Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened (한 측에서만 거칠기가 설치된 삼각덕트의 열전달과 압력강하 특성)

  • Ahn, S.W.;Lee, Y.S.;Lee, B.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.65-70
    • /
    • 2000
  • Experimental investigations were conducted to study the forced convection of fully-developed turbulent f)on· in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness Pitch ratio(P/e) of 4, 8 and 16 on the one side wall only The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70.000 to 10,000 The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement. measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion. namely the fin effect. And the results were compared with those of Previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

Three Dimmensional Turbulent Flow Analysis in a 90° Square Sectioned Duct with Strong Curvature (사각단면을 갖는 90° 급곡관의 3차원 난류유동 해석)

  • Maeng, J.S.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.11-25
    • /
    • 1991
  • The steady, incompressible developing 3-dimensional turblent flow in a square sectioned curved duct has been investigated by using partially-parabolic equation and Finite Analytic Method. The calculation of turbulent flow field is performed using 2-equation K-$\epsilon$ turbulence model, modified wall function, simpler algorithm and numerically generated body fitted coordinates. Iso-mean velocity contours at the various sections are compared with the existing experimental data and elliptic solutions by other authors. In the region of $0^{\circ}<{\theta}<71^{\circ}$, present results agree with the experimental data much better than the elliptic solution for the similar number of grid points. Furthermore, for the same tolerance, the present solution converges four times faster than the elliptic solution.

  • PDF

Emission Characteristics of LP Gas Burner for the Variation of Combustion Conditions (연소조건 변화에 따른 LP가스버너의 배기특성)

  • 이병곤;오택흠
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • An experimental study was carried out to investigate the emission characteristics of LP gas burner for the Practical combustion conditions including fm voltage, inlet area, gas Pressure, emission resistance, duct length and height. The result shows that CO is almost remains constant for the emission fan voltage, but significantly increases with the reduction rate of air inlet, up to 3000ppm at 50% of reduction rate. Also, the variation of gas pressure has no effect to CO of gas boiler due to its governor which controls gas pressure secondly, but it gives an rapid increase of CO for the gas range. The emission resistance test shows that CO is suddenly increased with the reduction rate of emission duct above 70% and main burner is stopped at 90%. The reverse wind test shows that CO is suddenly increased with the air velocity above 7m/s and main burner is stopped at 9m/s. The more horizontal length of emission duct is long and the vertical height is low, CO is infinitesimally increased.

  • PDF

A Study on Velocity Distribution Characteristics for Each Location and Effectiveness of Straight Duct Length in a Square-sectional 180° Bended Duct (정사각형 단면을 갖는 180° 곡관에서 위치별 속도분포특성 및 직관거리의 유효성에 관한 연구)

  • Chen, Jing-Jing;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.618-627
    • /
    • 2016
  • This study numerically analyzes the characteristics of the velocity distribution for each location of a square-sectional $180^{\circ}$ bent duct using a Reynolds Stress Turbulent model. The flow parameters were varied, including the working fluids, inlet velocity, surface roughness, radius of curvature, and hydraulic diameter. The boundary conditions for computational fluid dynamics analysis were inlet temperatures of air and water of 288 K and 293 K, inlet air velocity of 3-15 m/s, inner surface roughness of 0-0.001 mm, radius of curvature of 2.5-4.5 D, and hydraulic diameter of 70-100 mm. The working fluid characteristics were highly affected by changes in the viscous force. The maximum velocity profiles in the bent duct were indicated when the $90^{\circ}$ section was in the region of X/D=0.8 and the $180^{\circ}$ section was in the region of Y/D=0.8. Lower surface roughness and higher radius of curvature resulted in a higher rate of velocity change. Also, an efficient measuring location downstream of the bent duct is suggested since the flow deviations were the most stable when the straight duct length was in the region of L/D=30. The minimum deviations at the same velocity conditions according to the hydraulic diameter were mostly indicated in the range of L/D=15-30 based on the standard deviation characteristics.