• Title/Summary/Keyword: S/W Project Performance

Search Result 40, Processing Time 0.026 seconds

Effects of Dietary Calcium Levels on Productive Performance, Eggshell Quality and Overall Calcium Status in Aged Laying Hens

  • An, S.H.;Kim, D.W.;An, B.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.10
    • /
    • pp.1477-1482
    • /
    • 2016
  • This study was conducted to investigate the effects of diets with varying levels of calcium on egg production, shell quality and overall calcium status in aged laying hens. A total of five hundred 70-wk-old Hy-Line Brown layers were divided five groups and fed one of the five experimental diets with 3.5%, 3.8%, 4.1%, 4.4%, or 4.7% Ca, for 10 weeks. There were no significant differences in feed intake, egg production and egg weight among groups. The cracked eggs were linearly reduced as dietary Ca levels increased to 4.7% (p<0.01). A significant linear improvement for eggshell strength and thickness were determined with increasing dietary Ca levels (p<0.01). The contents of serum Ca and phosphorus were not affected by dietary Ca levels. With increase in dietary Ca levels, the tibial breaking strength slightly increased. There were no significant differences in the tibial contents of ash, Ca and phosphorus among groups. In conclusion, eggshell quality, as measured by appearance, strength and thickness of eggshell, were influenced by dietary Ca content as expected (p<0.05). These results suggested that aged laying hens require relatively higher level of Ca than required levels from current Korean feeding standards for poultry.

An Analysis of S/W Project Quality and Organizational Performance by SPICE Certification (SPICE인증 여부에 따른 프로젝트 품질성과 및 조직성과 분석)

  • Ryu Sung Hun;Lee Jea Hun;Lee Ki Hun;Lee Eunseok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.403-405
    • /
    • 2005
  • IT산업이 발달하고 고도화 됨에 따라 소프트웨어가 차지하는 비중이 점차 높아지고 있다. 국내의 경우 정보통신부가 2001년 하반기부터 소프트웨어업체 사업자 평가제도를 도입/시행 중으로 이에 따라 소프트웨어 개발/관리 조직들은 소프트웨어 품질 평가 심사모형인 5티CE 및 CMM의 등급 인증획득과 등급 상향을 위해 큰 관심과 노력을 기울이고 있다. 그러나 이중 SPICE 인증의 신뢰성이나 효과에 대한 충분한 검증 및 연구가 이루어 지고 있지 않아, 본 논문에서는 특히 SPICE 등급을 인증받은 조직이 비인증 조직과 비교하여 품질 및 성과에 차이를 보이는지 조사하였다. 자료수집의 한계에도 불구하고 본 논문을 통해 SPICE 인증 조직이 비인증 조직보다. 프로젝트 품질 성과 및 조직성과 측면에서 어떤 개선효과를 거두고 있는지 특히 피심사부서의 담당관련자들을 중심으로 조사, 분석하여 그 결과를 요약하였다.

  • PDF

Study on IEC 61850 Performance Testing Procedures of BF Protection IED (차단키 실패 보호 IED의 IEC 61850 시스템 성능 시험 절차서에 관한 연구)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.59-66
    • /
    • 2008
  • Korea Electric Power Research Institute in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology" is performing system verification. Breaker Failure protection IED can operate protection activity by communicating with other IEDs such as T/L IED, owing to IEC 61850 international standard and digital substation automation system. Accordingly, IED testing process should be changed from the conventional way by electrical contact test on individual IED to system based testing method by network communication. This paper describes how to test BF IED based on substation automation system and testing procedures using UML, which is used to implement S/W design.

Coordination Approach for Electronic Commerce Development (전자상거래 개발을 위한 코디네이션 접근 방식)

  • Kim, Hee-Woong;Malone, Thomas W.
    • Asia pacific journal of information systems
    • /
    • v.10 no.4
    • /
    • pp.133-152
    • /
    • 2000
  • Successful Electronic Commerce(EC) requires not only a transformation of the supply chain but a redesign of organizational processes as well. Just as the organizations in a supply chain must cooperate with each other to achieve a collective goal, so too do the departments and groups that comprise an organization depend on each other to achieve the organization's goals. A lack of coordination at either of these levels can result in poor performance and high coordination costs. In addition, changes in inter-organizational dependencies can affect the dependencies within the affected organizations. The lack of coordination across two levels results in a transition gap in transforming the inter-organizational design to the intro-organizational design in EC deployments. The purpose of this research is to develop a modeling method for coordination, managing the linkage between inter- and intra-organizations in EC deployments. The method was applied to the EC development project of a cable TV home-shopping company. The coordination approach enabled us to manage dependencies among the coordination elements and identify the effect of a change on other elements, which became the basis for effective EC deployments. We will discuss the method and compare it with other dependency management methods.

  • PDF

A Review on Urban Resilience Assessment Methods

  • Barjau, Jaime;Wong, Francis K.W.;Fang, Dongping
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.685-686
    • /
    • 2015
  • The world is currently undergoing an intense urbanization process. The percentage of urban dwellers has never been so high. In 2010, and for the first time, urban population surpassed the rural one, accounting for 51% of global population, and this trend will continue in the forthcoming years. This increment in concentration of population and supporting assets in cities, make their performance a critical issue for world population. Recent events such as Fukushima tsunami and the hurricane Katrina have shown how fragile built environments are and the unpredictability of occurrence and magnitude of the hazards. Such an expansion of the world's urban population, together with an increase in severity and number of hazards and catastrophes, has put under the spotlight the necessity to build cities not only sustainable, but resilient. Decision makers should acknowledge failure as an option, and the importance of developing city resilience. This paper will provide an initial review on urban resilience, definitions and assessment approaches as a first step for decision makers to account for resilience in their decision making process.

  • PDF

An Implementation of IEEE 1516.1-2000 Standard with the Hybrid Data Communication Method (하이브리드 데이터 통신 방식을 적용한 IEEE 1516.1-2000 표준의 구현)

  • Shim, Jun-Yong;Wi, Soung-Hyouk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.11
    • /
    • pp.1094-1103
    • /
    • 2012
  • Recently, software industry regarding national defense increases system development of distributed simulation system of M&S based to overcome limit of resource and expense. It is one of key technologies for offering of mutual validation among objects and reuse of objects which are discussed for developing these systems. RTI, implementation of HLA interface specification as software providing these technologies uses Federation Object Model for exchanging information with joined federates in the federation and each federate has a characteristic that is supposed to have identical FOM in the federation. This technology is a software which is to provide the core technology which was suggested by the United state's military M&S standard framework. Simulator, virtual simulation, and inter-connection between military weapons system S/W which executes on network which is M&S's core base technology, and it is a technology which also can be used for various inter-connection between S/W such as game and on-line phone. These days although RTI is used in military war game or tactical training unit field, there is none in Korea. Also, it is used in mobile-game, distribution game, net management, robot field, and other civilian field, but the number of examples are so small and informalized. Through this developing project, we developed the core technique and RTI software and provided performance of COTS level to improve communication algorithms.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Effect of Boundary Layer Generated on the fin surfaces of a Compact Heat Exchanger on the Heat Transfer and Pressure Drop Characteristics (컴팩트형 열교환기의 핀 표면에서 발생하는 경계층이 열교환기의 전열 및 압력강하 특성의 변화에 미치는 영향에 관한 수치해석적 연구)

  • KIM Chul-Ho;Jung Ji-Yong
    • Journal of computational fluids engineering
    • /
    • v.3 no.1
    • /
    • pp.82-88
    • /
    • 1998
  • As a par of a project related to the development of the design algorithm of a compact heat exchanger for the application of the electronic home appliances, the effect of the discreteness of the airflow boundary generated on the cooling fin surface on the heat transfer and pressure drop characteristics of the heat exchanger was studied numerically. In general, there are two critical design parameters seriously considered in the design of the heat exchanger; heat transfer rate(Q) and pressure drop coefficient(C/sub p/). Even though the higher heat transfer rate with lower pressure drop characteristics is required in a design of the heat exchanger, it is not an easy job to satisfy both conditions at the same time because these two parameters are phenomenally inversely proportional. To control the boundary layer thickness and its length along the streamline, the surface of the flat fin was modified to accelerate the heat transfer rate on the fin surface. To understand the effect of the discreted fin size(S/sub w/) and its location(S/sub h/) on the performance of the heat exchanger in the airflow field, the flat fin was modified as shown in Fig. 1. From this study, it was found that the smaller and more number of slits on the fin surface showed the higher energy diffusion rate. It means that the discreteness of the boundary layer is quite important on the heat transfer rate of the heat exchanger. On the other hand, if the fin surface configuration is very complex than needed, higher static pressure drop occurs than required in a system and it may be a reason of the induced aerodynamic noise in the heat exchanger.

  • PDF

Drainage Performance of Various Subsurface Drain Materials- (배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능-)

  • 김철회;이근후;유시조;서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF

Development of Robot Platform for Autonomous Underwater Intervention (수중 자율작업용 로봇 플랫폼 개발)

  • Yeu, Taekyeong;Choi, Hyun Taek;Lee, Yoongeon;Chae, Junbo;Lee, Yeongjun;Kim, Seong Soon;Park, Sanghyun;Lee, Tae Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.168-177
    • /
    • 2019
  • KRISO (Korea Research Institute of Ship & Ocean Engineering) started a project to develop the core algorithms for autonomous intervention using an underwater robot in 2017. This paper introduces the development of the robot platform for the core algorithms, which is an ROV (Remotely Operated Vehicle) type with one 7-function manipulator. Before the detailed design of the robot platform, the 7E-MINI arm of the ECA Group was selected as the manipulator. It is an electrical type, with a weight of 51 kg in air (30 kg in water) and a full reach of 1.4 m. To design a platform with a small size and light weight to fit in a water tank, the medium-size manipulator was placed on the center of platform, and the structural analysis of the body frame was conducted by ABAQUS. The robot had an IMU (Inertial Measurement Unit), a DVL (Doppler Velocity Log), and a depth sensor for measuring the underwater position and attitude. To control the robot motion, eight thrusters were installed, four for vertical and the rest for horizontal motion. The operation system was composed of an on-board control station and operation S/W. The former included devices such as a 300 VDC power supplier, Fiber-Optic (F/O) to Ethernet communication converter, and main control PC. The latter was developed using an ROS (Robot Operation System) based on Linux. The basic performance of the manufactured robot platform was verified through a water tank test, where the robot was manually operated using a joystick, and the robot motion and attitude variation that resulted from the manipulator movement were closely observed.